메뉴 건너뛰기




Volumn 14, Issue 1, 2003, Pages 17-31

Particle size measurement of standard reference particle candidates with improved size measurement devices

Author keywords

Liquid sedimentation method; Microscopic method; Size measurement; Standard reference particles; Stokes diameter

Indexed keywords

PARTICLES (PARTICULATE MATTER); REFRACTIVE INDEX; SEDIMENTATION; STANDARDS;

EID: 0037287312     PISSN: 09218831     EISSN: None     Source Type: Journal    
DOI: 10.1163/156855203762469876     Document Type: Article
Times cited : (21)

References (6)
  • 1
    • 22444453811 scopus 로고    scopus 로고
    • Data reduction in measurement of size distribution using sedimentation balance method
    • K. Fukui, H. Mizuta, M. Shiba, C. Yun and H. Yoshida, Data reduction in measurement of size distribution using sedimentation balance method, Kagaku Kougaku Ronbunshu 24, 928-933 (1998).
    • (1998) Kagaku Kougaku Ronbunshu , vol.24 , pp. 928-933
    • Fukui, K.1    Mizuta, H.2    Shiba, M.3    Yun, C.4    Yoshida, H.5
  • 2
    • 0033853125 scopus 로고    scopus 로고
    • Investigation about data reduction and sedimentation distance of sedimentation balance method
    • K. Fukui, H. Yoshida, M. Shiba and Y. Tokunaga, Investigation about data reduction and sedimentation distance of sedimentation balance method, J. Chem. Eng. Japan 33, 3 (2000).
    • (2000) J. Chem. Eng. Japan , vol.33 , pp. 3
    • Fukui, K.1    Yoshida, H.2    Shiba, M.3    Tokunaga, Y.4
  • 3
    • 85007991639 scopus 로고
    • Theoretical study of the scatter of experimental data due to particle size distribution
    • H. Masuda and K. Iinoya, Theoretical study of the scatter of experimental data due to particle size distribution, J. Chem. Eng., Japan 4, 60-67 (1971).
    • (1971) J. Chem. Eng. Japan , vol.4 , pp. 60-67
    • Masuda, H.1    Iinoya, K.2
  • 4
    • 0032647859 scopus 로고    scopus 로고
    • Study on the sample size required for the estimation of mean particle diameter
    • H. Masuda and K. Gotoh, Study on the sample size required for the estimation of mean particle diameter, Advnced Powder Technol. 10, 159-173 (1999).
    • (1999) Advnced Powder Technol. , vol.10 , pp. 159-173
    • Masuda, H.1    Gotoh, K.2
  • 5
    • 0001230424 scopus 로고
    • Comparison of constrained linear inversion and an iterative nonlinear algorithm applied to the indirect estimation of particle size distribution
    • S. Twomey, Comparison of constrained linear inversion and an iterative nonlinear algorithm applied to the indirect estimation of particle size distribution, J. Comput. Phys. 18, 188-200 (1975).
    • (1975) J. Comput. Phys. , vol.18 , pp. 188-200
    • Twomey, S.1
  • 6
    • 0035043688 scopus 로고    scopus 로고
    • Particle size measurement with an improved sedimentation balance method and microscopic method together with computer simulation of necessary sample size
    • H. Yoshida, H. Masuda, K. Fukui and Y. Tokunaga, Particle size measurement with an improved sedimentation balance method and microscopic method together with computer simulation of necessary sample size, Advanced Powder Technol. 12, 79-94 (2001).
    • (2001) Advanced Powder Technol. , vol.12 , pp. 79-94
    • Yoshida, H.1    Masuda, H.2    Fukui, K.3    Tokunaga, Y.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.