Volumn 37, Issue 1, 2003, Pages 44-53

The effects of different rack systems on the breeding performance of DBA/2 mice

Author keywords

Breeding performance; Environmental enrichment; Inbred mice; Individually ventilated cage; Ventilated cabinet

Indexed keywords

AMMONIA; CARBON DIOXIDE;

EID: 0037248278     PISSN: 00236772     EISSN: None     Source Type: Journal    
DOI: 10.1258/002367703762226683     Document Type: Article
Times cited : (43)

References (26)
  • 1
    • 0028929347 scopus 로고
    • A positive, individually ventilated caging system: A local barrier system to protect both animals and personnel
    • Clough G, Wallace J, Gamble MR, Merryweather ER, Bailey E (1995) A positive, individually ventilated caging system: a local barrier system to protect both animals and personnel. Laboratory Animals 29, 139-51
    • (1995) Laboratory Animals , vol.29 , pp. 139-151
    • Clough, G.1    Wallace, J.2    Gamble, M.R.3    Merryweather, E.R.4    Bailey, E.5
  • 2
    • 0026331172 scopus 로고
    • A comparison of rodent caging systems based on microenvironmental parameters
    • Corning BF, Lipman NS (1991) A comparison of rodent caging systems based on microenvironmental parameters. Laboratory Animal Science 41, 498-503
    • (1991) Laboratory Animal Science , vol.41 , pp. 498-503
    • Corning, B.F.1    Lipman, N.S.2
  • 3
    • 0026815980 scopus 로고
    • The effects of a mass air displacement unit on the microenvironmental parameters within isolator cages
    • Corning BF, Lipman NS (1992) The effects of a mass air displacement unit on the microenvironmental parameters within isolator cages. Laboratory Animal Science 42, 91-3
    • (1992) Laboratory Animal Science , vol.42 , pp. 91-93
    • Corning, B.F.1    Lipman, N.S.2
  • 4
    • 0012879725 scopus 로고
    • Pressurized, individually ventilated (PIV) cages in reducing transmission of pneumonia virus of mice
    • Cunliffe-Beamer TL, Les EP (1983) Pressurized, individually ventilated (PIV) cages in reducing transmission of pneumonia virus of mice. Laboratory Animal Science 33, 495
    • (1983) Laboratory Animal Science , vol.33 , pp. 495
    • Cunliffe-Beamer, T.L.1    Les, E.P.2
  • 5
    • 0031254124 scopus 로고    scopus 로고
    • Intracage air change rate on forced-air-ventilated micro-isolation system - Environment within the cages: Carbon dioxide and oxygen concentration
    • Haseggawa M, Kurabayashi Y, Ishii T, Yoshida K, Uebayashi N, Sato N, Kurosawa T (1997) Intracage air change rate on forced-air-ventilated micro-isolation system - environment within the cages: carbon dioxide and oxygen concentration. Journal of Experimental Animal Science 46, 251-7
    • (1997) Journal of Experimental Animal Science , vol.46 , pp. 251-257
    • Haseggawa, M.1    Kurabayashi, Y.2    Ishii, T.3    Yoshida, K.4    Uebayashi, N.5    Sato, N.6    Kurosawa, T.7
  • 6
    • 0035173711 scopus 로고    scopus 로고
    • Evaluation of individually ventilated cage systems for laboratory rodents: Cage environment and animal health aspects
    • Höglund A, Renström A (2001) Evaluation of individually ventilated cage systems for laboratory rodents: cage environment and animal health aspects. Laboratory Animals 35, 51-7
    • (2001) Laboratory Animals , vol.35 , pp. 51-57
    • Höglund, A.1    Renström, A.2
  • 7
    • 0027535964 scopus 로고
    • Ivermectin eradication of pinworms from rats kept in ventilated cages
    • Huerkamp MJ (1993) Ivermectin eradication of pinworms from rats kept in ventilated cages. Laboratory Animal Science 43, 86-90
    • (1993) Laboratory Animal Science , vol.43 , pp. 86-90
    • Huerkamp, M.J.1
  • 8
    • 0032144060 scopus 로고    scopus 로고
    • Invention of a forced-air-ventilated micro-isolation cage and rack system - Environment within the cages: Temperature and ammonia concentration
    • Ishii T, Yoshida K, Haseggawa M, Mizuno S, Okamoto M, Tajima M, Kurosawa T (1998) Invention of a forced-air-ventilated micro-isolation cage and rack system - environment within the cages: temperature and ammonia concentration. Applied Animal Behavior Science 59, 115-23
    • (1998) Applied Animal Behavior Science , vol.59 , pp. 115-123
    • Ishii, T.1    Yoshida, K.2    Haseggawa, M.3    Mizuno, S.4    Okamoto, M.5    Tajima, M.6    Kurosawa, T.7
  • 9
    • 0014273636 scopus 로고
    • Comparison of bedding material: Habitat preference of pregnant mice and reproductive performance
    • Iturrian W, Fink GB (1968) Comparison of bedding material: habitat preference of pregnant mice and reproductive performance. Laboratory Animal Care 18, 160-4
    • (1968) Laboratory Animal Care , vol.18 , pp. 160-164
    • Iturrian, W.1    Fink, G.B.2
  • 10
    • 0012808042 scopus 로고
    • Comparison of microenvironmental conditions in standard versus forced-air ventilated rodent filter-top cages
    • Iwarsson K, Norén L (1992) Comparison of microenvironmental conditions in standard versus forced-air ventilated rodent filter-top cages. Scandinavian Journal of Laboratory Animal Science 19, 167-73
    • (1992) Scandinavian Journal of Laboratory Animal Science , vol.19 , pp. 167-173
    • Iwarsson, K.1    Norén, L.2
  • 13
    • 0027675151 scopus 로고
    • Invention of an air forced ventilated micro-isolation cage and rack system - Environment within the cages: Ventilation, air flow
    • Kurosawa T, Yoshida K, Okamoto M, Tajima M (1993) Invention of an air forced ventilated micro-isolation cage and rack system - environment within the cages: ventilation, air flow. Journal of Experimental Animal Science 42, 547-54
    • (1993) Journal of Experimental Animal Science , vol.42 , pp. 547-554
    • Kurosawa, T.1    Yoshida, K.2    Okamoto, M.3    Tajima, M.4
  • 15
    • 0012853623 scopus 로고
    • Pressurized, individually ventilated (PIV) and individually exhausted caging for laboratory mice
    • Les EP (1983) Pressurized, individually ventilated (PIV) and individually exhausted caging for laboratory mice. Laboratory Animal Science 33, 495
    • (1983) Laboratory Animal Science , vol.33 , pp. 495
    • Les, E.P.1
  • 16
    • 0026654050 scopus 로고
    • The effects of intracage ventilation on microenvironmental conditions in filter-top cages
    • Lipman NS, Cornin BF, Coiro MA (1992) The effects of intracage ventilation on microenvironmental conditions in filter-top cages. Laboratory Animals 26, 206-10
    • (1992) Laboratory Animals , vol.26 , pp. 206-210
    • Lipman, N.S.1    Cornin, B.F.2    Coiro, M.A.3
  • 17
    • 0001885522 scopus 로고
    • Characterization and quantification of microenvironmental contaminants in isolator cages with a variety of contact beddings
    • Perkins SE, Lipman NS (1995) Characterization and quantification of microenvironmental contaminants in isolator cages with a variety of contact beddings. Contemporary Topics in Laboratory Animal Science 34, 93-8
    • (1995) Contemporary Topics in Laboratory Animal Science , vol.34 , pp. 93-98
    • Perkins, S.E.1    Lipman, N.S.2
  • 18
    • 0002018531 scopus 로고    scopus 로고
    • Evaluation of micro-environmental conditions and noise generation in three individually ventilated rodent caging system and static isolator cages
    • Perkins SE, Lipman NS (1996) Evaluation of micro-environmental conditions and noise generation in three individually ventilated rodent caging system and static isolator cages. Contemporary Topics in Laboratory Animal Science 35, 61-5
    • (1996) Contemporary Topics in Laboratory Animal Science , vol.35 , pp. 61-65
    • Perkins, S.E.1    Lipman, N.S.2
  • 22
    • 0035161089 scopus 로고    scopus 로고
    • Evaluation of individually ventilated cage systems for laboratory rodents: Occupational health aspects
    • Renström A, Bjoring G, Hoglund AU (2001) Evaluation of individually ventilated cage systems for laboratory rodents: occupational health aspects. Laboratory Animals 35, 42-50
    • (2001) Laboratory Animals , vol.35 , pp. 42-50
    • Renström, A.1    Bjoring, G.2    Hoglund, A.U.3
  • 25
    • 0024577847 scopus 로고
    • Evaluation of a one-way airflow system in an animal room based on counts of airborne dust particles and bacteria and measurements of ammonia levels
    • Yamauchi C, Obara T, Fukuyama N, Ueda T (1989) Evaluation of a one-way airflow system in an animal room based on counts of airborne dust particles and bacteria and measurements of ammonia levels. Laboratory Animals 23, 7-15
    • (1989) Laboratory Animals , vol.23 , pp. 7-15
    • Yamauchi, C.1    Obara, T.2    Fukuyama, N.3    Ueda, T.4
  • 26
    • 0029381696 scopus 로고
    • Invention of a forced-air-ventilated micro-isolation cage and rack system - Environment within the cages, temperature and ammonia concentration
    • Yoshida K, Okamoto M, Tajima M, Kurosawa T (1995) Invention of a forced-air-ventilated micro-isolation cage and rack system - environment within the cages, temperature and ammonia concentration. Experimental Animals 43, 703-10
    • (1995) Experimental Animals , vol.43 , pp. 703-710
    • Yoshida, K.1    Okamoto, M.2    Tajima, M.3    Kurosawa, T.4