메뉴 건너뛰기




Volumn 55, Issue 1, 2003, Pages 93-98

Measurement of pharmaceutical particles using a time-of-flight particle sizer

Author keywords

Aerosizer; Deagglomeration; Particle size; Pharmaceutical particle; Shear force; Time of flight

Indexed keywords

CELPHERE; DRUG; LACTOSE; MICROCRYSTALLINE CELLULOSE; POLY(3 HYDROXYBUTYRIC ACID); POVIDONE;

EID: 0037243610     PISSN: 09396411     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0939-6411(02)00139-X     Document Type: Article
Times cited : (10)

References (9)
  • 1
    • 0002281529 scopus 로고
    • Aerosol beam spectrometry
    • Dahneke B.E. Aerosol beam spectrometry. Nat. Phys. Sci. 244:1973;54-55.
    • (1973) Nat. Phys. Sci. , vol.244 , pp. 54-55
    • Dahneke, B.E.1
  • 2
    • 0002528865 scopus 로고
    • Aerodynamic particle size testing using a time-of-flight aerosol beam spectrometer
    • Niven R.W. Aerodynamic particle size testing using a time-of-flight aerosol beam spectrometer. Pharm. Technol. 17:1993;72-78.
    • (1993) Pharm. Technol. , vol.17 , pp. 72-78
    • Niven, R.W.1
  • 3
    • 0029733383 scopus 로고    scopus 로고
    • Dry powder dispersion system for particle size analysis using aerodynamic time-of-flight
    • Bohan J.F. Dry powder dispersion system for particle size analysis using aerodynamic time-of-flight. Powder Handl. Process. 8:1996;59-61.
    • (1996) Powder Handl. Process. , vol.8 , pp. 59-61
    • Bohan, J.F.1
  • 4
    • 0029851032 scopus 로고    scopus 로고
    • ® for the real-time measurement of medical aerosols from pressurized metered-dose inhaler (pMDI) systems
    • ® for the real-time measurement of medical aerosols from pressurized metered-dose inhaler (pMDI) systems. Aerosol Sci. Technol. 25:1996;411-423.
    • (1996) Aerosol Sci. Technol. , vol.25 , pp. 411-423
    • Mitchell, J.P.1    Nagel, M.W.2
  • 5
    • 0033106719 scopus 로고    scopus 로고
    • ® aerodynamic particle size analyzer to characterize aerosols from pressurized metered-dose inhalers (pMDIs) for medication delivery
    • ® aerodynamic particle size analyzer to characterize aerosols from pressurized metered-dose inhalers (pMDIs) for medication delivery. J. Aerosol Sci. 30:1999;467-477.
    • (1999) J. Aerosol Sci. , vol.30 , pp. 467-477
    • Mitchell, J.P.1    Nagel, M.W.2    Cheng, Y.S.3
  • 6
    • 0002213224 scopus 로고
    • Size distribution control of raw materials for dry powder inhalers using the Aerosizer with the Aero-Disperser
    • Hindle M., Byron P.R. Size distribution control of raw materials for dry powder inhalers using the Aerosizer with the Aero-Disperser. Pharm. Technol. June:1995;64-78.
    • (1995) Pharm. Technol. , vol.JUNE , pp. 64-78
    • Hindle, M.1    Byron, P.R.2
  • 7
    • 0026027636 scopus 로고
    • Coincidence in time of flight aerosol spectrometers: Phantom particle creation
    • Heitbrink W.A., Baron P.A., Willeke K. Coincidence in time of flight aerosol spectrometers: Phantom particle creation. Aerosol Sci. Technol. 14:1991;112-126.
    • (1991) Aerosol Sci. Technol. , vol.14 , pp. 112-126
    • Heitbrink, W.A.1    Baron, P.A.2    Willeke, K.3
  • 9
    • 0000425854 scopus 로고
    • Particle engineering by supercritical fluid technologies for powder inhalation drug delivery
    • P.R. Byron, R.N. Dalby, Farr S.J. Buffalo Grove IL: InterPharm Press
    • York P., Hanna M. Particle engineering by supercritical fluid technologies for powder inhalation drug delivery. Byron P.R., Dalby R.N., Farr S.J. Respiratory Drug Delivery. 1994;231-239 InterPharm Press, Buffalo Grove IL.
    • (1994) Respiratory Drug Delivery , pp. 231-239
    • York, P.1    Hanna, M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.