1
-
-
0020561952
-
Bending stiffness of unilateral and bilateral fixator frames
-
Behrens F, Johnson WD, Koch TW, Kovacevic N: Bending stiffness of unilateral and bilateral fixator frames. Clin Orthop 178:103-110, 1983.
-
(1983)
Clin Orthop
, vol.178
, pp. 103-110
-
-
Behrens, F.1
Johnson, W.D.2
Koch, T.W.3
Kovacevic, N.4
-
2
-
-
0023679936
-
Mechanical performance of the standard Orthofix external fixator
-
Chao EY, Hein TJ: Mechanical performance of the standard Orthofix external fixator. Orthopedics 11:1057-1069, 1988.
-
(1988)
Orthopedics
, vol.11
, pp. 1057-1069
-
-
Chao, E.Y.1
Hein, T.J.2
-
3
-
-
0002368994
-
Biomechanics of fracture fixation
-
Mow VC, Hayes WC (eds). Philadelphia, Lippincott-Raven
-
Chao EYS, Aro HT: Biomechanics of Fracture Fixation. In Mow VC, Hayes WC (eds). Basic Biomechanics. Ed 2. Philadelphia, Lippincott-Raven 317-351, 1997.
-
(1997)
Basic Biomechanics. Ed 2
, pp. 317-351
-
-
Chao, E.Y.S.1
Aro, H.T.2
-
5
-
-
0031802661
-
Reuse of external skeletal fixator components: Effects on costs and complications
-
Dirschl DR, Smith JJ: Reuse of external skeletal fixator components: Effects on costs and complications. J Trauma 44:855-858, 1998.
-
(1998)
J Trauma
, vol.44
, pp. 855-858
-
-
Dirschl, D.R.1
Smith, J.J.2
-
6
-
-
0025579642
-
Applying tribological principles to improve the performance of the Hoffmann external fixator's universal joint
-
Drijber FL, Finlay JB: Applying tribological principles to improve the performance of the Hoffmann external fixator's universal joint. Proc Inst Mech Eng [H] 204:253-258, 1990.
-
(1990)
Proc Inst Mech Eng [H]
, vol.204
, pp. 253-258
-
-
Drijber, F.L.1
Finlay, J.B.2
-
7
-
-
0026410852
-
Joint slippage in the Hoffmann external fixator. No effect of loading rate in bench experiments
-
Drijber FL, Finlay JB: Joint slippage in the Hoffmann external fixator. No effect of loading rate in bench experiments. Acta Orthop Scand 62:535-537, 1991.
-
(1991)
Acta Orthop Scand
, vol.62
, pp. 535-537
-
-
Drijber, F.L.1
Finlay, J.B.2
-
8
-
-
0026738517
-
Universal joint slippage as a cause of Hoffmann half-frame external fixator failure
-
Drijber FL, Finlay JB: Universal joint slippage as a cause of Hoffmann half-frame external fixator failure. J Biomed Eng 14:509-515, 1992.
-
(1992)
J Biomed Eng
, vol.14
, pp. 509-515
-
-
Drijber, F.L.1
Finlay, J.B.2
-
9
-
-
0025332128
-
Source of the slippage in the universal joints of the Hoffmann external fixator
-
Drijber FL, Finlay JB, Moroz TK, Rorabeck CH: Source of the slippage in the universal joints of the Hoffmann external fixator. Med Biol Eng Comput 28:8-14, 1990.
-
(1990)
Med Biol Eng Comput
, vol.28
, pp. 8-14
-
-
Drijber, F.L.1
Finlay, J.B.2
Moroz, T.K.3
Rorabeck, C.H.4
-
10
-
-
0021708696
-
Fatigue performance of external fixator pins
-
Kasman RA, Chao EY: Fatigue performance of external fixator pins. J Orthop Res 2:377-384, 1984.
-
(1984)
J Orthop Res
, vol.2
, pp. 377-384
-
-
Kasman, R.A.1
Chao, E.Y.2
-
11
-
-
4243813339
-
Mechanical performance of a serrated joint in a unilateral fixator design
-
Hong Kong
-
Mastuura M, Kim YH, Inoue N, Walulik S, Chao EYS: Mechanical performance of a serrated joint in a unilateral fixator design. Proceedings of Seventh Biannual Meeting, International Society of Fracture Repair. Hong Kong, A-7, 2000.
-
(2000)
Proceedings of Seventh Biannual Meeting, International Society of Fracture Repair
-
-
Mastuura, M.1
Kim, Y.H.2
Inoue, N.3
Walulik, S.4
Chao, E.Y.S.5
-
12
-
-
0024253927
-
External skeletal fixation: Choosing a system based on biomechanical stability
-
Moroz TK, Finlay JB, Rorabeck CH, Bourne RB: External skeletal fixation: Choosing a system based on biomechanical stability. J Orthop Trauma 2:284-296, 1988.
-
(1988)
J Orthop Trauma
, vol.2
, pp. 284-296
-
-
Moroz, T.K.1
Finlay, J.B.2
Rorabeck, C.H.3
Bourne, R.B.4
-
13
-
-
0027510012
-
Refracture of adolescent femoral shaft fractures: A complication of external fixation: A report of two cases
-
Probe R, Lindsey RW, Hadley NA, Barnes DA: Refracture of adolescent femoral shaft fractures: A complication of external fixation: A report of two cases. J Pediatr Orthop 13:102-105, 1993.
-
(1993)
J Pediatr Orthop
, vol.13
, pp. 102-105
-
-
Probe, R.1
Lindsey, R.W.2
Hadley, N.A.3
Barnes, D.A.4
-
14
-
-
0027519893
-
Wear of polyethylene acetabular cups against alumina femoral heads: Five prostheses compared in a hip simulator for 35 million walking cycles
-
Saikko VO: Wear of polyethylene acetabular cups against alumina femoral heads: Five prostheses compared in a hip simulator for 35 million walking cycles. Acta Orthop Scand 64:507-512, 1993.
-
(1993)
Acta Orthop Scand
, vol.64
, pp. 507-512
-
-
Saikko, V.O.1
-
15
-
-
0021320105
-
Fatigue properties of the Hoffman-Vidal external fixation apparatus
-
Shiba R, Chao EYS, Kasman R: Fatigue properties of the Hoffman-Vidal external fixation apparatus. Orthopedics 7:443-456, 1984.
-
(1984)
Orthopedics
, vol.7
, pp. 443-456
-
-
Shiba, R.1
Chao, E.Y.S.2
Kasman, R.3
-
16
-
-
0032833121
-
Secondary fractures associated with external fixation in pediatric femur fractures
-
Skaggs DL, Leet AI, Money MD, et al: Secondary fractures associated with external fixation in pediatric femur fractures. J Pediatr Orthop 19:582-586, 1999.
-
(1999)
J Pediatr Orthop
, vol.19
, pp. 582-586
-
-
Skaggs, D.L.1
Leet, A.I.2
Money, M.D.3
-
17
-
-
0027078512
-
Compression plating for non-union after failed external fixation of open tibial fractures
-
Wiss DA, Johnson DL, Miao M: Compression plating for non-union after failed external fixation of open tibial fractures. J Bone Joint Surg 74A:1279-1285, 1992.
-
(1992)
J Bone Joint Surg
, vol.74 A
, pp. 1279-1285
-
-
Wiss, D.A.1
Johnson, D.L.2
Miao, M.3
|