메뉴 건너뛰기




Volumn 141, Issue 1, 2003, Pages 105-111

Computer-assisted navigated cup placement in primary and secondary dysplastic hips;Computerassistierte hüftpfannennavigation bei primär- und sekundär dysplastischen ausgangssituationen

Author keywords

CAS system; Cup position; Dyplastic cases; Navigation; Total hip arthroplasty

Indexed keywords

ADULT; ARTICLE; CLINICAL ARTICLE; CLINICAL FEATURE; CLINICAL TRIAL; COMPUTER ASSISTED TOMOGRAPHY; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; HIP DYSPLASIA; HUMAN; RANDOMIZED CONTROLLED TRIAL; RELIABILITY; THREE DIMENSIONAL IMAGING; TOTAL HIP PROSTHESIS; TREATMENT PLANNING;

EID: 0037233615     PISSN: 00443220     EISSN: None     Source Type: Journal    
DOI: 10.1055/s-2003-37306     Document Type: Article
Times cited : (27)

References (21)
  • 1
    • 0033385696 scopus 로고    scopus 로고
    • Ceramic acetabular cups for hip endoprothesis: How do position of the center of rotation and CCD angle of the shaft modify range of motion and impingement?
    • Bader R, Willmann G. Ceramic acetabular cups for hip endoprothesis: How do position of the center of rotation and CCD angle of the shaft modify range of motion and impingement? Biomed Tech (Berl) 1999; 44 (12): 345-351
    • (1999) Biomed Tech (Berl) , vol.44 , Issue.12 , pp. 345-351
    • Bader, R.1    Willmann, G.2
  • 2
    • 0002105285 scopus 로고    scopus 로고
    • Einfluss von Implantatdesign und -lage auf Range of Motion und Impingement bei künstlichem Hüftgelenksersatz
    • Bader R, Willmann G. Einfluss von Implantatdesign und -lage auf Range of Motion und Impingement bei künstlichem Hüftgelenksersatz. Z Orthop 2000; 138 (S1): 19-20
    • (2000) Z Orthop , vol.138 , Issue.S1 , pp. 19-20
    • Bader, R.1    Willmann, G.2
  • 3
    • 0034500183 scopus 로고    scopus 로고
    • Computerassistierte navigierte Pfannenplatzierung in der Hüftendoprothetik - Anwendungsstudie im klinischen Routinealltag
    • Bernsmann K, Langlotz U, Ansari B, Wiese M. Computerassistierte navigierte Pfannenplatzierung in der Hüftendoprothetik - Anwendungsstudie im klinischen Routinealltag. Z Orthop 2000; 138: 515-521
    • (2000) Z Orthop , vol.138 , pp. 515-521
    • Bernsmann, K.1    Langlotz, U.2    Ansari, B.3    Wiese, M.4
  • 4
    • 0035676423 scopus 로고    scopus 로고
    • Computerassistierte navigierte Platzierung von verschiedenen Pfannentypen in der Hüftendoprothetik - Eine randomisierte kontrollierte Studie
    • Bernsmann K, Langlotz U, Ansari B, Wiese M. Computerassistierte navigierte Platzierung von verschiedenen Pfannentypen in der Hüftendoprothetik - eine randomisierte kontrollierte Studie. Z Orthop 2001; 139: 512-516
    • (2001) Z Orthop , vol.139 , pp. 512-516
    • Bernsmann, K.1    Langlotz, U.2    Ansari, B.3    Wiese, M.4
  • 5
    • 12244277252 scopus 로고    scopus 로고
    • Dysplasie-Coxarthrose mit Sekundärpfanne - Endoprothesen-Implantation in die Primär- oder Sekundärpfanne?
    • Büttner-Janz K, Jessen N. Dysplasie-Coxarthrose mit Sekundärpfanne - Endoprothesen-Implantation in die Primär- oder Sekundärpfanne? Z Orthop 1998; 136: A47
    • (1998) Z Orthop , vol.136
    • Büttner-Janz, K.1    Jessen, N.2
  • 7
    • 0034923052 scopus 로고    scopus 로고
    • Risikofaktoren für die Luxation einer zementfreien Hüfttotalendoprothese - Eine statistische Analyse
    • Giurea A, Zehetgruber H, Funovics P, Grampp S, Karamat L, Gottsauner-Wolf F. Risikofaktoren für die Luxation einer zementfreien Hüfttotalendoprothese - Eine statistische Analyse. Z Orthop 2001; 139: 194-199
    • (2001) Z Orthop , vol.139 , pp. 194-199
    • Giurea, A.1    Zehetgruber, H.2    Funovics, P.3    Grampp, S.4    Karamat, L.5    Gottsauner-Wolf, F.6
  • 8
    • 0026096424 scopus 로고
    • Der Pfannenerkeraufbau - Eine spezifische Ergänzung des totalendoprothetischen Hüftgelenksersatzes
    • Gleißner F, Wessinghage D, Fitzek JG. Der Pfannenerkeraufbau - eine spezifische Ergänzung des totalendoprothetischen Hüftgelenksersatzes. Z Orthop 1991; 129: 188-193
    • (1991) Z Orthop , vol.129 , pp. 188-193
    • Gleißner, F.1    Wessinghage, D.2    Fitzek, J.G.3
  • 9
    • 12244272896 scopus 로고    scopus 로고
    • Vorteile der CT-gestützten Hüftpfannennavigation bei Dysplasiecoxarthrosen und Wechselsituationen
    • Haaker R, Stockheim M, Rubenthaler F. Vorteile der CT-gestützten Hüftpfannennavigation bei Dysplasiecoxarthrosen und Wechselsituationen. Z Orthop 2001; 139: S59
    • (2001) Z Orthop , vol.139
    • Haaker, R.1    Stockheim, M.2    Rubenthaler, F.3
  • 10
    • 12244259559 scopus 로고    scopus 로고
    • Total Hip Arhtroplasty: Options for young people. Proceedings 6th international Biolox Symposium
    • Toni A, Willmann G (eds). Stuttgart: Thieme
    • Haaker R, Stockheim M. Total Hip Arhtroplasty: Options for young people. Proceedings 6th international Biolox Symposium. In: Toni A, Willmann G (eds). Bioceramics in Joint Arthroplasry. Stuttgart: Thieme, 2001: 18-21
    • (2001) Bioceramics in Joint Arthroplasry , pp. 18-21
    • Haaker, R.1    Stockheim, M.2
  • 11
    • 12244252585 scopus 로고    scopus 로고
    • Computerassistierte navigation yon schraubpfannen
    • Effenberger (Hrsg). Steinkopf: im Druck
    • Haaker R, Stockheim M, Langlotz F. Computerassistierte Navigation yon Schraubpfannen. In: Effenberger (Hrsg). Die Schraubpfanne. Steinkopf, 2002: im Druck
    • (2002) Die Schraubpfanne
    • Haaker, R.1    Stockheim, M.2    Langlotz, F.3
  • 12
    • 12244300389 scopus 로고    scopus 로고
    • Hüftpfannennavigation mit dem SurgiGate-System in Dysplasie- und Wechselsituationen
    • Haaker R, Konermann W (Hrsg). Heidelberg: Springer
    • Haaker R. Hüftpfannennavigation mit dem SurgiGate-System in Dysplasie- und Wechselsituationen. In: Haaker R, Konermann W (Hrsg). Navigation und Robotik in der Gelenk- und Wirbelsäulenchirurgie. Heidelberg: Springer, 2002
    • (2002) Navigation und Robotik in der Gelenk- und Wirbelsäulenchirurgie
    • Haaker, R.1
  • 13
    • 0025975977 scopus 로고
    • Die Balgrist-Pfanne in der zementfreien Endoprothetik von Dysplasie coxarthrosen und von anderen Acetabulumdefekten
    • Hauser R. Die Balgrist-Pfanne in der zementfreien Endoprothetik von Dysplasie coxarthrosen und von anderen Acetabulumdefekten. Z Orthop 1991; 129: 183-187
    • (1991) Z Orthop , vol.129 , pp. 183-187
    • Hauser, R.1
  • 14
    • 0012550222 scopus 로고    scopus 로고
    • Roboterassistierte Implantation der femoralen Komponente einet Hüftendoprothese - Eine experimentelle Untersuchung
    • Jerosch J, Hasselbach C, Filler T, Peuker E, Rahgozar M, Lahmer A, Witzel U. Roboterassistierte Implantation der femoralen Komponente einet Hüftendoprothese - eine experimentelle Untersuchung. Orthop Praxis 1999; 35: 632-641
    • (1999) Orthop Praxis , vol.35 , pp. 632-641
    • Jerosch, J.1    Hasselbach, C.2    Filler, T.3    Peuker, E.4    Rahgozar, M.5    Lahmer, A.6    Witzel, U.7
  • 16
    • 0012598308 scopus 로고    scopus 로고
    • Movement Mapping (MM) als dynamische Operationsplanung von Hüftendoprothesen. Eine Voraussetzung zur Navigation?
    • Jerosch J, Weipert A, Hanusek S. Movement Mapping (MM) als dynamische Operationsplanung von Hüftendoprothesen. Eine Voraussetzung zur Navigation? Orthop Praxis 2001: 37: 735-739
    • (2001) Orthop Praxis , vol.37 , pp. 735-739
    • Jerosch, J.1    Weipert, A.2    Hanusek, S.3
  • 17
    • 0030623842 scopus 로고    scopus 로고
    • Die Verrenkung der Hüftendoprothese unter besonderer Beachtung verschiedener Zugangswege
    • Kohn D, Ruhmann O, Wirth CJ. Die Verrenkung der Hüftendoprothese unter besonderer Beachtung verschiedener Zugangswege. Z Orthop 1997; 135: 40-44
    • (1997) Z Orthop , vol.135 , pp. 40-44
    • Kohn, D.1    Ruhmann, O.2    Wirth, C.J.3
  • 19
    • 0026522003 scopus 로고
    • Computed tomography measurement of acetabular cuop anteversion and retroversion in total hip arthroplasty
    • Mian SW, Truchly G, Pflum FA. Computed tomography measurement of acetabular cuop anteversion and retroversion in total hip arthroplasty. Clin Orthop 1992; 276: 206-209
    • (1992) Clin Orthop , vol.276 , pp. 206-209
    • Mian, S.W.1    Truchly, G.2    Pflum, F.A.3
  • 20
    • 0032999147 scopus 로고    scopus 로고
    • Verringerte Pfannenanteversion und Schenkelhalsantetorsion verursachten Schmerz und Arthrose
    • Tönnis D, Heinecke A. Verringerte Pfannenanteversion und Schenkelhalsantetorsion verursachten Schmerz und Arthrose. Z Orthop 1999; 137: 153-167
    • (1999) Z Orthop , vol.137 , pp. 153-167
    • Tönnis, D.1    Heinecke, A.2
  • 21
    • 12244252064 scopus 로고    scopus 로고
    • Ergebnisse der manuellen und computernavigierten Implantation einer Monoblock-press-Fit-Pfanne mit Tantalumoberfläche
    • Widmer KH, Ackermann JP, Bereiter H. Ergebnisse der manuellen und computernavigierten Implantation einer Monoblock-press-Fit-Pfanne mit Tantalumoberfläche. Z Orthop 2001; 139: S59
    • (2001) Z Orthop , vol.139
    • Widmer, K.H.1    Ackermann, J.P.2    Bereiter, H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.