Volumn 21, Issue 1, 2003, Pages 23-27

Coronal multiplanar reconstruction view from isotropic voxel data sets obtained with multidetector-row CT: Assessment of detection and size of mediastinal and hilar lymph nodes

Author keywords

Isotropic resolution; Lymph node; Mediastinum; Multidetector; Multiplannar reconstruction (MPR); Row computed tomography (MDCT)

Indexed keywords

ADULT; AGED; ARTICLE; CLINICAL ARTICLE; COMPUTER ASSISTED TOMOGRAPHY; DIAGNOSTIC IMAGING; FEMALE; HUMAN; IMAGE RECONSTRUCTION; LUNG HILUS; LUNG SARCOIDOSIS; LYMPH NODE METASTASIS; LYMPHOMA; MALE; MEDIASTINUM LYMPH NODE;

EID: 0037231970     PISSN: 02882043     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (21)

References (11)
  • 2
    • 0028811590 scopus 로고
    • Multiplanar display of spiral CT data of the pulmonary hila in patients with lung cancer. Preliminary observations
    • Padhani AR, Fishman EK, Heitmiller RF, Wang KP, Wheeler JH, Kuhlman JE. Multiplanar display of spiral CT data of the pulmonary hila in patients with lung cancer. Preliminary observations. Clin Imaging, 1995; 19: 252-257.
    • (1995) Clin Imaging , vol.19 , pp. 252-257
    • Padhani, A.R.1    Fishman, E.K.2    Heitmiller, R.F.3    Wang, K.P.4    Wheeler, J.H.5    Kuhlman, J.E.6
  • 3
    • 0033919451 scopus 로고    scopus 로고
    • Stair-step artifacts with single versus multiple detector-row helical CT
    • Fleischmann D, Rubin GD, Paik DS, et al. Stair-step artifacts with single versus multiple detector-row helical CT. Radiology, 2000; 216: 185-196.
    • (2000) Radiology , vol.216 , pp. 185-196
    • Fleischmann, D.1    Rubin, G.D.2    Paik, D.S.3
  • 4
    • 0034069213 scopus 로고    scopus 로고
    • Four multidetector-row helical CT: Image quality and volume coverage speed
    • Hu H, He HD, Foley WD, Fox SH. Four multidetector-row helical CT: image quality and volume coverage speed. Radiology, 2000, 215: 55-62.
    • (2000) Radiology , vol.215 , pp. 55-62
    • Hu, H.1    He, H.D.2    Foley, W.D.3    Fox, S.H.4
  • 5
    • 0034330627 scopus 로고    scopus 로고
    • Multisection CT: Scanning techniques and clinical applications
    • Rydberg J, Buckwalter KA, Caldemeyer KS, et al. Multisection CT: scanning techniques and clinical applications. Radiographics, 2000; 20: 1787-1806.
    • (2000) Radiographics , vol.20 , pp. 1787-1806
    • Rydberg, J.1    Buckwalter, K.A.2    Caldemeyer, K.S.3
  • 8
    • 0032793092 scopus 로고    scopus 로고
    • Evaluation of small internal mammary lymph node metastases in breast cancer by MRI
    • Kinoshita T, Odagiri K, Andoh K, et al. Evaluation of small internal mammary lymph node metastases in breast cancer by MRI. Radiat Med, 1999, 17: 189-193.
    • (1999) Radiat Med , vol.17 , pp. 189-193
    • Kinoshita, T.1    Odagiri, K.2    Andoh, K.3
  • 9
    • 0034594628 scopus 로고    scopus 로고
    • New guidelines to evaluate the response to treatment in solid tumors
    • Patrick T, Sugan GA, Elizabeth AE, et al. New guidelines to evaluate the response to treatment in solid tumors. J Natl Cancer Inst, 2000, 92: 205-216.
    • (2000) J Natl Cancer Inst , vol.92 , pp. 205-216
    • Patrick, T.1    Sugan, G.A.2    Elizabeth, A.E.3
  • 10
    • 0034938431 scopus 로고    scopus 로고
    • Differential diagnosis of small round cervical lymph nodes: Comparison of power doppler US with contrast-enhanced CT and pathologic results
    • Sakaguchi T, Yamashita Y, Katahira K, et al. Differential diagnosis of small round cervical lymph nodes: comparison of power doppler US with contrast-enhanced CT and pathologic results. Radiat Med, 2001, 19: 115-125.
    • (2001) Radiat Med , vol.19 , pp. 115-125
    • Sakaguchi, T.1    Yamashita, Y.2    Katahira, K.3
  • 11
    • 0032824577 scopus 로고    scopus 로고
    • Electrocardiographically gated thin-section CT of the lung
    • Schoepf UJ, Becker CR, Bruening RD, et al. Electrocardiographically gated thin-section CT of the lung. Radiology, 1999, 212: 649-654.
    • (1999) Radiology , vol.212 , pp. 649-654
    • Schoepf, U.J.1    Becker, C.R.2    Bruening, R.D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.