Inappropriate shock delivery and biventricular pacing cardiac defibrillators

Author keywords

Arrhythmia prevention control; Biventricular pacing; Cardiac pacing, artificial methods; Cardiac resynchronization; Defibrillators, implantable; Inappropriate shocks; Tachycardia, ventricular therapy; Ventricular double counting

Indexed keywords

ADULT; AGED; ARTICLE; ARTIFICIAL HEART PACEMAKER; CASE REPORT; CONGESTIVE HEART FAILURE; DEFIBRILLATOR; DISEASE COURSE; ELECTRIC SHOCK; ELECTROCARDIOGRAM; HEART ATRIUM FIBRILLATION; HEART DEPOLARIZATION; HEART LEFT VENTRICLE; HEART PACING; HEART RIGHT VENTRICLE; HIGH RISK PATIENT; HUMAN; IMPLANTATION; MALE; SUDDEN DEATH; TREATMENT OUTCOME;

EID: 0037221955     PISSN: 07302347     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (5)

References (6)
  • 1
    • 0034933919 scopus 로고    scopus 로고
    • Biventricular pacing therapy for congestive heart failure: A review of the literature
    • Conti JB. Biventricular pacing therapy for congestive heart failure: a review of the literature. Cardiol Rev 2001;9:217-26.
    • (2001) Cardiol Rev , vol.9 , pp. 217-226
    • Conti, J.B.1
  • 3
    • 0034958429 scopus 로고    scopus 로고
    • Inappropriate shock delivery due to ventricular double detection with a biventricular pacing implantable cardioverter defibrillator
    • Schreieck J, Zrenner B, Kolb C, Ndrepepa G, Schmitt C. Inappropriate shock delivery due to ventricular double detection with a biventricular pacing implantable cardioverter defibrillator. Pacing Clin Electrophysiol 2001;24:1154-7.
    • (2001) Pacing Clin Electrophysiol , vol.24 , pp. 1154-1157
    • Schreieck, J.1    Zrenner, B.2    Kolb, C.3    Ndrepepa, G.4    Schmitt, C.5
  • 5
    • 0028279498 scopus 로고
    • Oversensing during ventricular pacing in patients with a third-generation implantable cardioverter-defibrillator
    • Kelley PA, Mann DE, Damle RS, Reiter MJ. Oversensing during ventricular pacing in patients with a third-generation implantable cardioverter-defibrillator. J Am Coll Cardiol 1994;23(7):1531-4.
    • (1994) J Am Coll Cardiol , vol.23 , Issue.7 , pp. 1531-1534
    • Kelley, P.A.1    Mann, D.E.2    Damle, R.S.3    Reiter, M.J.4
  • 6
    • 0033053953 scopus 로고    scopus 로고
    • Inappropriate shocks delivered by implantable cardiac defibrillators during oversensing of activity of diaphragmatic muscle
    • Babuty D, Fauchier L, Cosnay P. Inappropriate shocks delivered by implantable cardiac defibrillators during oversensing of activity of diaphragmatic muscle. Heart 1999;81:94-6.
    • (1999) Heart , vol.81 , pp. 94-96
    • Babuty, D.1    Fauchier, L.2    Cosnay, P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.