Volumn 38, Issue 2, 2003, Pages 429-438

Mapping air contaminant concentrations using remote sensing FTIR

Author keywords

FTIR; Gas monitoring; Mapping; Remote sensing

Indexed keywords

CONCENTRATION (PROCESS); CONTOUR MEASUREMENT; ENVIRONMENTAL PROTECTION; FOURIER TRANSFORM INFRARED SPECTROSCOPY; IMPURITIES; INDUSTRIAL EMISSIONS; METHANOL; REMOTE SENSING;

EID: 0037219529     PISSN: 10934529     EISSN: None     Source Type: Journal    
DOI: 10.1081/ESE-120016905     Document Type: Article
Times cited : (9)

References (25)
  • 3
    • 0242699666 scopus 로고
    • Optical remote sensing/computed tomography systems for workplace exposure assessments. Optical remote sensing applications to environmental and industrial safety problems
    • Todd, L.A. Optical remote sensing/computed tomography systems for workplace exposure assessments. Optical remote sensing applications to environmental and industrial safety problems. Air and Waste Manage. Assoc. 1992, SP81, 356-360.
    • (1992) Air and Waste Manage. Assoc. , vol.SP81 , pp. 356-360
    • Todd, L.A.1
  • 4
    • 0242615478 scopus 로고
    • Optical remote sensing/computed tomography beam geometries for monitoring workplace gases and vapors. Optical remote sensing applications to environmental and industrial safety problems
    • Todd, L.A. Optical remote sensing/computed tomography beam geometries for monitoring workplace gases and vapors. Optical remote sensing applications to environmental and industrial safety problems. Air and Waste Manage. Assoc. 1992, SP81, 390-393.
    • (1992) Air and Waste Manage. Assoc. , vol.SP81 , pp. 390-393
    • Todd, L.A.1
  • 5
    • 0028439577 scopus 로고
    • Workplace and environmental air contaminant concentrations measured by open path Fourier transform infrared spectroscopy: A statistic process control technique to detect changes from normal operating conditions
    • Malachowsli, M.S.; Levine, S.P.; Herrin, G.; Spear, R.C.; Yost, M.; Yi, Z. Workplace and environmental air contaminant concentrations measured by open path Fourier transform infrared spectroscopy: a statistic process control technique to detect changes from normal operating conditions. Air and Waste 1994, 44, 673-682.
    • (1994) Air and Waste , vol.44 , pp. 673-682
    • Malachowsli, M.S.1    Levine, S.P.2    Herrin, G.3    Spear, R.C.4    Yost, M.5    Yi, Z.6
  • 6
    • 0032650658 scopus 로고    scopus 로고
    • Ambient gaseous leak detection using radial scanning computed tomography and optical remote sensing
    • Hashmonay, R.A.; Yost, M.G.; Wu, C.F. Ambient gaseous leak detection using radial scanning computed tomography and optical remote sensing. SPIE 1998, 3534, 126-132.
    • (1998) SPIE , vol.3534 , pp. 126-132
    • Hashmonay, R.A.1    Yost, M.G.2    Wu, C.F.3
  • 7
    • 0032179619 scopus 로고    scopus 로고
    • A unique application of an extractive FTIR ambient air monitoring system for the simultaneous detection of multiple-ppb-level VOCs
    • Cantu, A.; Pophal, G.; Hall, S.; Laush, C.T. A unique application of an extractive FTIR ambient air monitoring system for the simultaneous detection of multiple-ppb-level VOCs. App. Phys. 1998, B67, 493-496.
    • (1998) App. Phys. , vol.B67 , pp. 493-496
    • Cantu, A.1    Pophal, G.2    Hall, S.3    Laush, C.T.4
  • 8
    • 0031106502 scopus 로고    scopus 로고
    • Stationary and time-dependent indoor tracer-gas concentration profiles measured by OP-FTIR remote sensing and SBFM-computed tomography
    • Drescher, A.C.; Park, D.Y.; Yost, M.G.; Gadgil, A.J.; Nazaroff, W.W. Stationary and time-dependent indoor tracer-gas concentration profiles measured by OP-FTIR remote sensing and SBFM-computed tomography. Atmospheric Environment 1997, 31, 727-740.
    • (1997) Atmospheric Environment , vol.31 , pp. 727-740
    • Drescher, A.C.1    Park, D.Y.2    Yost, M.G.3    Gadgil, A.J.4    Nazaroff, W.W.5
  • 9
    • 0242615480 scopus 로고
    • Design and calibration of a mobile laboratory for on-site measurements of volatile organic compounds (VOCs) using Fourier transform infrared spectroscopy (FT-IR)
    • Erickson, L.E., Ed.; Kansas State University Extension: Manhattan, Kansas
    • Spartz, M.L.; Fateley, J.H.; Witkowski, M.R.; Hammaker, R.M.; Fateley, W.G. Design and calibration of a mobile laboratory for on-site measurements of volatile organic compounds (VOCs) using Fourier transform infrared spectroscopy (FT-IR). In Proceedings of the Conference on Hazardous Waste Research; Erickson, L.E., Ed.; Kansas State University Extension: Manhattan, Kansas, 1989; 328-346.
    • (1989) Proceedings of the Conference on Hazardous Waste Research , pp. 328-346
    • Spartz, M.L.1    Fateley, J.H.2    Witkowski, M.R.3    Hammaker, R.M.4    Fateley, W.G.5
  • 11
    • 0032651765 scopus 로고    scopus 로고
    • Trends and future applications of optical remote sensing and computed tomography to map air contaminants
    • Todd, L.A.; Yost, M.G.; Hashmonay, R.A. Trends and future applications of optical remote sensing and computed tomography to map air contaminants. SPIE 1998, 3534, 399-404.
    • (1998) SPIE , vol.3534 , pp. 399-404
    • Todd, L.A.1    Yost, M.G.2    Hashmonay, R.A.3
  • 12
    • 0032681602 scopus 로고    scopus 로고
    • Simulation study for gaseous fluxes from an area source using computed tomography and optical remote sensing
    • Hashmonay, R.A.; Yost, M.G.; Harris, D.B.; Thompson, E.L. Simulation study for gaseous fluxes from an area source using computed tomography and optical remote sensing. SPIE 1998, 3534, 405-410.
    • (1998) SPIE , vol.3534 , pp. 405-410
    • Hashmonay, R.A.1    Yost, M.G.2    Harris, D.B.3    Thompson, E.L.4
  • 13
    • 0033403611 scopus 로고    scopus 로고
    • Measurement of volatile organic compound (VOC) concentration profiles in the atmosphere of a remote forest region
    • Schubert, P.; Rosenberg, E.; Grasserbaner, M. Measurement of volatile organic compound (VOC) concentration profiles in the atmosphere of a remote forest region. Int. J. Environ. Anal. Chem. 1999, 75, 127-147.
    • (1999) Int. J. Environ. Anal. Chem. , vol.75 , pp. 127-147
    • Schubert, P.1    Rosenberg, E.2    Grasserbaner, M.3
  • 14
    • 0028060461 scopus 로고
    • Optical remote sensing for air pollutants-review
    • Simonds, M.; Xiao, H.; Levine, S.P. Optical remote sensing for air pollutants-review. Am. Ind. Hyg. Ass. J. 1994, 53, 953-965.
    • (1994) Am. Ind. Hyg. Ass. J. , vol.53 , pp. 953-965
    • Simonds, M.1    Xiao, H.2    Levine, S.P.3
  • 15
    • 0019035181 scopus 로고
    • Remote Fourier transform infrared air pollution studies
    • Herget, W.F.; Brasher, J.D. Remote Fourier transform infrared air pollution studies. Opt. Eng. 1980, 19, 508-514.
    • (1980) Opt. Eng. , vol.19 , pp. 508-514
    • Herget, W.F.1    Brasher, J.D.2
  • 16
    • 0003697050 scopus 로고
    • Remote sensing by fourier transform spectrometry
    • Wiley-Interscience Publication: New York
    • Beer, R. Remote Sensing by Fourier Transform Spectrometry. Chemical Analysis; Wiley-Interscience Publication: New York, 1992; Vol. 120.
    • (1992) Chemical Analysis , pp. 120
    • Beer, R.1
  • 17
    • 85076557988 scopus 로고
    • Passive remote detection of atmospheric pollutants using fourier transform infrared (FTIR) spectroscopy
    • Hilton, M.; Lettington, A.H.; Mills, I.M. Passive remote detection of atmospheric pollutants using fourier transform infrared (FTIR) spectroscopy. SPIE 1993, 2089, 214-315.
    • (1993) SPIE , vol.2089 , pp. 214-315
    • Hilton, M.1    Lettington, A.H.2    Mills, I.M.3
  • 18
    • 0020097258 scopus 로고
    • Remote and cross-stack measurement of stack gas concentrations using a mobile FT-IR system
    • Herget, W. Remote and cross-stack measurement of stack gas concentrations using a mobile FT-IR system. App. Opt. 1982, 21, 635-641.
    • (1982) App. Opt. , vol.21 , pp. 635-641
    • Herget, W.1
  • 19
    • 0001136656 scopus 로고
    • Winefordner, J.D., Ed.; John Wiley & Sons, Inc.: New York, Chap VI
    • Sigrit, M.W. Air Monitoring by Spectroscopic Techniques; Winefordner, J.D., Ed.; John Wiley & Sons, Inc.: New York, 1994, Chap. VI, 335-470.
    • (1994) Air Monitoring by Spectroscopic Techniques , pp. 335-470
    • Sigrit, M.W.1
  • 21
    • 0033800342 scopus 로고    scopus 로고
    • Long-Path FTIR spectroscopic studies of air pollutants in the danube refinery plant
    • Hren, B.; Katona, K.; Mink, J.; Kohan, J.; Isaak, Gy. Long-Path FTIR spectroscopic studies of air pollutants in the danube refinery plant. Analyst 2000, 125, 1655-1659.
    • (2000) Analyst , vol.125 , pp. 1655-1659
    • Hren, B.1    Katona, K.2    Mink, J.3    Kohan, J.4    Isaak, G.Y.5
  • 24
    • 0028143613 scopus 로고
    • Validation of a method for estimating pollution emission rates from area sources using open-path FTIR spectroscopy and dispersion modeling techniques
    • Piccot, S.D.; Masemore, S.S.; Ringler, E.S.; Srinivasan, S.; Kirchgessner, D.A.; Herget, W.F. Validation of a method for estimating pollution emission rates from area sources using open-path FTIR spectroscopy and dispersion modeling techniques. J. Air & Waste Management. Assoc. 1994, 44, 271-279.
    • (1994) J. Air & Waste Management. Assoc. , vol.44 , pp. 271-279
    • Piccot, S.D.1    Masemore, S.S.2    Ringler, E.S.3    Srinivasan, S.4    Kirchgessner, D.A.5    Herget, W.F.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.