메뉴 건너뛰기




Volumn 36, Issue 1, 2003, Pages 57-63

A small 2D ultrasonic array for NDT applications

Author keywords

2D segmented annular array; 3D ultrasonic imaging; Volumetric NDE

Indexed keywords

COMPUTER SIMULATION; NONDESTRUCTIVE EXAMINATION; SIGNAL TO NOISE RATIO; ULTRASONIC TRANSDUCERS;

EID: 0037218999     PISSN: 09638695     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0963-8695(02)00072-5     Document Type: Article
Times cited : (28)

References (9)
  • 1
    • 0026189516 scopus 로고
    • Beam steering with pulsed two-dimensional transducer arrays
    • Turnbull D.H., Foster F.S. Beam steering with pulsed two-dimensional transducer arrays. IEEE Trans UFFC. 38:(4):1991;320-333.
    • (1991) IEEE Trans UFFC , vol.38 , Issue.4 , pp. 320-333
    • Turnbull, D.H.1    Foster, F.S.2
  • 3
    • 0031234930 scopus 로고    scopus 로고
    • Broad-bandwidth radiation patterns of sparse two-dimensional vernier arrays
    • Brunke S.S., Lockwood G.R. Broad-bandwidth radiation patterns of sparse two-dimensional vernier arrays. IEEE Trans UFFC. 44:(5):1997;1101-1109.
    • (1997) IEEE Trans UFFC , vol.44 , Issue.5 , pp. 1101-1109
    • Brunke, S.S.1    Lockwood, G.R.2
  • 4
    • 0343878140 scopus 로고    scopus 로고
    • Comparison of CW beam patterns from segmented annular arrays and squared arrays
    • Martínez O., Ullate L.G., Ibañez A. Comparison of CW beam patterns from segmented annular arrays and squared arrays. Sensors Actuat A. 85:2000;33-37.
    • (2000) Sensors Actuat A , vol.85 , pp. 33-37
    • Martínez, O.1    Ullate, L.G.2    Ibañez, A.3
  • 5
    • 0035639696 scopus 로고    scopus 로고
    • Computation of the ultrasonic field radiate by segmented-annular arrays
    • Martínez O., Ullate L.G., Montero de Espinosa F. Computation of the ultrasonic field radiate by segmented-annular arrays. J Comput Acoust. 9:(3):2001;757-772.
    • (2001) J Comput Acoust , vol.9 , Issue.3 , pp. 757-772
    • Martínez, O.1    Ullate, L.G.2    Montero de Espinosa, F.3
  • 6
    • 0027148831 scopus 로고
    • Analytical comparison of sensor signal processing enhancements for NDT synthetic aperture ultrasonic imaging
    • Silverstein S.D., Thomas L.J. Analytical comparison of sensor signal processing enhancements for NDT synthetic aperture ultrasonic imaging. IEEE Trans Image Process. 2:(1):1993;60-67.
    • (1993) IEEE Trans Image Process , vol.2 , Issue.1 , pp. 60-67
    • Silverstein, S.D.1    Thomas, L.J.2
  • 8
    • 0001912586 scopus 로고
    • Tayloring the properties of 1-3 piezoelectric composites
    • Smith W., Shaoulov A. Tayloring the properties of 1-3 piezoelectric composites. Proc IEEE Ultrason Symp. 1985;642-647.
    • (1985) Proc IEEE Ultrason Symp , pp. 642-647
    • Smith, W.1    Shaoulov, A.2