메뉴 건너뛰기




Volumn 47, Issue 2, 2003, Pages 127-134

Microelectrode array sensor for water quality monitoring

Author keywords

Arsenic; Chlorine; Dissolved oxygen; Microelectrode array; On line water monitoring; Ozone

Indexed keywords

HIGH PRESSURE EFFECTS; MICROELECTRODES; MICROSENSORS; POTABLE WATER;

EID: 0037215002     PISSN: 02731223     EISSN: None     Source Type: Journal    
DOI: 10.2166/wst.2003.0102     Document Type: Conference Paper
Times cited : (12)

References (14)
  • 1
    • 0003720830 scopus 로고
    • Electrochemical device for chemical analysis
    • U.S. Patent 2,913,386 Nov. 17
    • Clark, L. (1959). Electrochemical device for chemical analysis, U.S. Patent 2,913,386 Nov. 17.
    • (1959)
    • Clark, L.1
  • 3
    • 0034994232 scopus 로고    scopus 로고
    • Development of an on-line chlorine sensor for water quality monitoring in public distribution networks
    • Gobet, J., Rychen, Ph., Madore, Ch., Skinner, N., Van Buel, H. and Jaggi, F. (2001). Development of an on-line chlorine sensor for water quality monitoring in public distribution networks. Wat. Sci. Tech.: Water Supply, 1(2), 211-216.
    • (2001) Wat. Sci. Tech.: Water Supply , vol.1 , Issue.2 , pp. 211-216
    • Gobet, J.1    Rychen, Ph.2    Madore, Ch.3    Skinner, N.4    Van Buel, H.5    Jaggi, F.6
  • 4
    • 33751130426 scopus 로고
    • Ultramicroelectrodes in electrochemistry
    • Heinze, J. (1993). Ultramicroelectrodes in electrochemistry. Angew. Chem. Int. Ed. Engl., 32, 1268-1288.
    • (1993) Angew. Chem. Int. Ed. Engl. , vol.32 , pp. 1268-1288
    • Heinze, J.1
  • 5
    • 0000381186 scopus 로고    scopus 로고
    • Microelectrode sensors for biomedical and environmental applications
    • Koudelka-Hep, M. and Van Der Wal, P. (2000). Microelectrode sensors for biomedical and environmental applications. Electrochimica Acta, 45(15) 2437-2441.
    • (2000) Electrochimica Acta , vol.45 , Issue.15 , pp. 2437-2441
    • Koudelka-Hep, M.1    Van Der Wal, P.2
  • 6
    • 0033668234 scopus 로고    scopus 로고
    • Microfabricated ultramicroelectrode arrays: Developments, advances and applications in environmental analysis
    • Kounaves, S. and Feeney, R. (2000). Microfabricated ultramicroelectrode arrays: Developments, advances and applications in environmental analysis. Electroanalysis, 12, 677-84.
    • (2000) Electroanalysis , vol.12 , pp. 677-684
    • Kounaves, S.1    Feeney, R.2
  • 8
    • 0030578901 scopus 로고    scopus 로고
    • Theoretical treatment of the amperometric current response of multiple microelectrode arrays
    • Morf, W. (1996). Theoretical treatment of the amperometric current response of multiple microelectrode arrays. Analytica Chimica Acta, 330, 139-149.
    • (1996) Analytica Chimica Acta , vol.330 , pp. 139-149
    • Morf, W.1
  • 9
    • 0032108204 scopus 로고    scopus 로고
    • Failure analysis of microfabricated iridium ultramicroelectrodes in chloride media
    • Nolan, M. and Kounaves, S. (1998). Failure analysis of microfabricated iridium ultramicroelectrodes in chloride media. Sensors and Actuators B, 50, 117-124.
    • (1998) Sensors and Actuators B , vol.50 , pp. 117-124
    • Nolan, M.1    Kounaves, S.2
  • 10
    • 0029867456 scopus 로고    scopus 로고
    • Towards a microelectrode sensor for the determination of oxygen in waters
    • Pletcher, D. and Sotiropoulos, S. (1996). Towards a microelectrode sensor for the determination of oxygen in waters. Analytica Chimica Acta, 322, 83-90.
    • (1996) Analytica Chimica Acta , vol.322 , pp. 83-90
    • Pletcher, D.1    Sotiropoulos, S.2
  • 11
    • 0025870073 scopus 로고
    • Studies of a microelectrode sensor for monitoring chlorine in water supplies
    • Pletcher, D. and Valdes, E.M. (1991). Studies of a microelectrode sensor for monitoring chlorine in water supplies. Analytica Chimica Acta, 246, 267-273.
    • (1991) Analytica Chimica Acta , vol.246 , pp. 267-273
    • Pletcher, D.1    Valdes, E.M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.