메뉴 건너뛰기




Volumn 16, Issue 1, 2003, Pages 19-26

Critical condition of backdraft in compartment fires: A reduced-scale experimental study

Author keywords

Backdraft; Critical condition

Indexed keywords

BUILDINGS; COMBUSTION; FUELS; OXYGEN; VENTILATION;

EID: 0037208181     PISSN: 09504230     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0950-4230(02)00088-8     Document Type: Article
Times cited : (35)

References (13)
  • 2
    • 0003758520 scopus 로고
    • University of Canterbury, New Zealand, Fire Engineering Research Report
    • Bolliger, I. B. (1995). Full residential-scale backdraft. University of Canterbury, New Zealand, Fire Engineering Research Report 95/1.
    • (1995) Full Residential-Scale Backdraft , vol.1-95
    • Bolliger, I.B.1
  • 3
    • 0001885586 scopus 로고
    • Modeling backdraft: The fire at 62 watts street
    • Bukowski, R. W. (1995). Modeling backdraft: The fire at 62 Watts Street. NFPA Journal, 89(6), 85-89.
    • (1995) NFPA Journal , vol.89 , Issue.6 , pp. 85-89
    • Bukowski, R.W.1
  • 4
    • 0004279869 scopus 로고
    • National Institute of Standards and Technology, USA, NIST-GCR-94-646
    • Fleischmann, C. M. (1994). Backdraft phenomenon. National Institute of Standards and Technology, USA, NIST-GCR-94-646.
    • (1994) Backdraft Phenomenon
    • Fleischmann, C.M.1
  • 7
    • 0032691789 scopus 로고    scopus 로고
    • Numerical and experimental gravity currents related to backdrafts
    • Fleischmann, C. M., and McGrattan, K. B. (1999). Numerical and experimental gravity currents related to backdrafts. Fire Safety Journal, 33, 21-34.
    • (1999) Fire Safety Journal , vol.33 , pp. 21-34
    • Fleischmann, C.M.1    McGrattan, K.B.2
  • 9
    • 0002548561 scopus 로고    scopus 로고
    • The development and mitigation of backdrafts: A full-scale experimental study
    • Australia: International Association for Fire Safety Science
    • Gottuk, D. T., Williams, F. W., and Farley, J. P. (1997). The development and mitigation of backdrafts: A full-scale experimental study. In Proceedings of the fifth international symposium on fire safety science (pp. 935-946). Australia: International Association for Fire Safety Science.
    • (1997) Proceedings of the Fifth International Symposium on Fire Safety Science , pp. 935-946
    • Gottuk, D.T.1    Williams F., W.2    Farley, J.P.3
  • 10
    • 0033328984 scopus 로고    scopus 로고
    • The development and mitigation of backdraft: A real-scale shipborad study
    • Gottuk, D. T., Peatross, M. J., Farley, J. P., and Williams, F. W. (1999). The development and mitigation of backdraft: A real-scale shipborad study. Fire Safety Journal, 33, 261-282.
    • (1999) Fire Safety Journal , vol.33 , pp. 261-282
    • Gottuk, D.T.1    Peatross, M.J.2    Farley, J.P.3    Williams, F.W.4
  • 11
    • 0000965381 scopus 로고
    • A robust bidirectional lowvelocity probe for flame and fire application
    • McCaffrey, B. J., and Heskestand, G. (1976). A robust bidirectional lowvelocity probe for flame and fire application. Combustion and Flame, 2, 6125-6127.
    • (1976) Combustion and Flame , vol.2 , pp. 6125-6127
    • McCaffrey, B.J.1    Heskestand, G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.