메뉴 건너뛰기




Volumn 125, Issue 1, 2002, Pages 22-36

Background interference from car carpets - The evidential value of petrol residues in cases of suspected vehicle arson

Author keywords

Accelerants; Arson; Carpet; Fire; Gasoline; Matrix interference; Motor vehicles; Petrol

Indexed keywords

GASOLINE;

EID: 0037165248     PISSN: 03790738     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0379-0738(01)00610-7     Document Type: Article
Times cited : (30)

References (21)
  • 1
    • 0030884930 scopus 로고    scopus 로고
    • The incidence of ignitable liquid residues in fire debris as determined by a sensitive and comprehensive analytical scheme
    • (1997) J. Forensic Sci. , vol.42 , Issue.5 , pp. 828-832
    • Jackowski, J.P.1
  • 2
    • 85167646424 scopus 로고    scopus 로고
    • I.C. Stone, M.S. Lomonte, False positives in analysis of fire debris, The Fire and Arson Investigator 34 (3) (1984).
  • 5
    • 0028101095 scopus 로고
    • Volatiles from carpet: a source of frequent misinterpretation in arson analysis
    • (1994) J. Chromatogr. A , vol.674 , pp. 329-333
    • Bertsch, W.1
  • 7
    • 85167646148 scopus 로고    scopus 로고
    • J.D. DeHaan, Kirk's Fire Investigation, 4th Edition, Prentice Hall, Englewood Cliffs, NJ, 1997.
  • 8
    • 85167642341 scopus 로고    scopus 로고
    • S.H. Kang, C.S. Oulman, Evaporation of petroleum products from contaminated soils. J. Environ. Eng. May (1996) 384-386.
  • 10
    • 85167648208 scopus 로고    scopus 로고
    • M. Darrer, O. Delemont, E. Du Pasquier, J. Papilloud, J.C. Martin, Collection and persistence of gasoline on hands, in: Proceedings of the Second European Meeting of Forensic Science, Cracow, Poland, 12-16 September 2000.
  • 13
    • 85167629674 scopus 로고    scopus 로고
    • Australia Now-A Statistical Profile of Transport Registered Motor Vehicles, Australian Bureau of Statistics, 1999.
  • 14
    • 85167649145 scopus 로고    scopus 로고
    • ASTM-E 1387-95 (Standard Test Method for Ignitable Liquid Residues in Extracts from Fire Debris Samples by Gas Chromatography).
  • 15
    • 85167647891 scopus 로고    scopus 로고
    • ASTM-E 1618-94 (Standard Test Method for Ignitable Liquid Extracts by Gas Chromatography-Mass Spectrometry).
  • 16
    • 85167635966 scopus 로고    scopus 로고
    • ASTM-E 1412-95 (Standard Practice for Separation and Concentration of Ignitable Liquid Residues from Fire Debris Samples by Passive Headspace Concentration).
  • 18
    • 0029882305 scopus 로고    scopus 로고
    • The use activated charcoal strips for fire debris extractions by passive diffusion. Part 1. The effects of time, temperature, strip size, and sample concentration
    • (1996) J. Forensic Sci. , vol.41 , Issue.3 , pp. 361-370
    • Newman, R.T.1    Dietz, W.R.2    Lothridge, K.3
  • 19
    • 85167629938 scopus 로고    scopus 로고
    • A. Braithwaite, F.J. Smith, Chromatographic Methods, 5th Edition, Chapman & Hall, NZ, 1996.
  • 20
    • 85167636917 scopus 로고    scopus 로고
    • W.R. Dietz, Physical evidence of arson: it's recognition, collection and packaging, The Fire and Arson Investigator 41 (4) (1991).
  • 21
    • 85167646790 scopus 로고    scopus 로고
    • J.L. Sanderson, C.A. Balliet, M.A. Balliet, Sampling techniques for accelerant residue analysis, The Fire and Arson Investigator 40 (3) (1990).


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.