메뉴 건너뛰기




Volumn 87, Issue 3, 2002, Pages 457-463

Study of odor blender using solenoid valves controlled by delta-sigma modulation method for odor recorder

Author keywords

Delta sigma modulation; Odor recipe; Odor recorder; Odor sensing system

Indexed keywords

COMPOSITION EFFECTS; COMPUTER SIMULATION; DELTA SIGMA MODULATION; LOW PASS FILTERS; ODORS; OPTIMIZATION; SOLENOIDS;

EID: 0037146832     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0925-4005(02)00300-3     Document Type: Article
Times cited : (68)

References (11)
  • 1
    • 0001310936 scopus 로고    scopus 로고
    • You've got smell!
    • Platt C. You've got smell! Wired. 11:1999;256.
    • (1999) Wired , vol.11 , pp. 256
    • Platt, C.1
  • 2
    • 0039648323 scopus 로고    scopus 로고
    • Comments on the use of olfactory displays for virtual environments
    • Barfield W., Danas E. Comments on the use of olfactory displays for virtual environments. Presence. 5(1):1996;109-121.
    • (1996) Presence , vol.5 , Issue.1 , pp. 109-121
    • Barfield, W.1    Danas, E.2
  • 3
    • 0033280572 scopus 로고    scopus 로고
    • Electronic noses: A review of signal processing techniques
    • Hines E.L., Gardner E.J.W. Electronic noses: a review of signal processing techniques. IEE Proc.-Circuits Devices Syst. 146(6):1999;297-310.
    • (1999) IEE Proc.-Circuits Devices Syst. , vol.146 , Issue.6 , pp. 297-310
    • Hines, E.L.1    Gardner, E.J.W.2
  • 4
    • 0023363493 scopus 로고
    • Multicomponent analysis using an array of piezoelectric crystal sensors
    • Carey W.P., Beebe K.R., Kowalski B.R. Multicomponent analysis using an array of piezoelectric crystal sensors. Anal. Chem. 59(11):1987;1529-1534.
    • (1987) Anal. Chem. , vol.59 , Issue.11 , pp. 1529-1534
    • Carey, W.P.1    Beebe, K.R.2    Kowalski, B.R.3
  • 5
    • 0028476268 scopus 로고
    • Application of iteration technique in association with multiple regression method for identification of mixtures of gases using an integrated gas-sensor array
    • Nayak M.S., Dwivedi R., Srivastava S.K. Application of iteration technique in association with multiple regression method for identification of mixtures of gases using an integrated gas-sensor array. Sens. Actuators B. 21:1994;11-16.
    • (1994) Sens. Actuators B , vol.21 , pp. 11-16
    • Nayak, M.S.1    Dwivedi, R.2    Srivastava, S.K.3
  • 6
    • 0028442953 scopus 로고
    • Active gas/odor sensing system using automatically controlled gas blender and numerical optimization technique
    • Nakamoto T., Ustumi S., Yamashita N., Moriizumi T., Sonoda Y. Active gas/odor sensing system using automatically controlled gas blender and numerical optimization technique. Sens. Actuators B. 20:1994;131-137.
    • (1994) Sens. Actuators B , vol.20 , pp. 131-137
    • Nakamoto, T.1    Ustumi, S.2    Yamashita, N.3    Moriizumi, T.4    Sonoda, Y.5
  • 7
    • 0031168646 scopus 로고    scopus 로고
    • High speed active gas/odor sensing system using adaptive control theory
    • Nakamoto T., Okazaki N., Moriizumi T. High speed active gas/odor sensing system using adaptive control theory. Sens. Actuators B. 41:1997;183-188.
    • (1997) Sens. Actuators B , vol.41 , pp. 183-188
    • Nakamoto, T.1    Okazaki, N.2    Moriizumi, T.3
  • 10
    • 0034512482 scopus 로고    scopus 로고
    • Vapor supply method in odor sensing system and analysis of transient sensor responses
    • Nakamoto T., Iguchi A., Moriizumi T. Vapor supply method in odor sensing system and analysis of transient sensor responses. Sens. Actuators B. 71:2000;155-160.
    • (2000) Sens. Actuators B , vol.71 , pp. 155-160
    • Nakamoto, T.1    Iguchi, A.2    Moriizumi, T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.