Volumn 95, Issue 1-2, 2002, Pages 65-79
|
Lab scale experiments for permeable reactive barriers against contaminated groundwater with ammonium and heavy metals using clinoptilolite (01-29B)
|
Author keywords
Ammonium; Clinoptilolite; Heavy metal; Permeable reactive barriers
|
Indexed keywords
AMMONIUM COMPOUNDS;
GROUNDWATER;
HEAVY METALS;
ION EXCHANGE;
PARTICLE SIZE ANALYSIS;
ZEOLITES;
CATION EXCHANGE CAPACITY (CEC);
WATER POLLUTION;
AMMONIA;
CLINOPTILOLITE;
GROUND WATER;
HEAVY METAL;
UNCLASSIFIED DRUG;
ZEOLITE;
AMMONIUM COMPOUND;
CLAY;
GROUNDWATER;
HEAVY METAL;
POLLUTION;
REACTIVE SEPARATION;
AMMONIUM;
GROUNDWATER POLLUTION;
HEAVY METAL;
REMEDIATION;
ARTICLE;
CATION EXCHANGE;
CONCENTRATION RESPONSE;
EXTRACTION;
LABORATORY TEST;
PARTICLE SIZE;
PERMEABILITY;
WATER CONTAMINATION;
CHEMISTRY, PHYSICAL;
METALS, HEAVY;
PARTICLE SIZE;
PERMEABILITY;
QUATERNARY AMMONIUM COMPOUNDS;
WATER POLLUTANTS;
ZEOLITES;
|
EID: 0037065183
PISSN: 03043894
EISSN: None
Source Type: Journal
DOI: 10.1016/S0304-3894(02)00007-9 Document Type: Article |
Times cited : (120)
|
References (9)
|