메뉴 건너뛰기




Volumn 57, Issue 11, 2002, Pages 1789-1799

Surface and gas phase temperatures of a tungsten coil atomizer

Author keywords

Electrothermal atomic absorption spectrometry; Temperature; Tungsten coil atomizer

Indexed keywords

ATOMIZATION; ELECTRIC CURRENTS; PYROMETERS; SPECTROMETERS;

EID: 0037064376     PISSN: 05848547     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0584-8547(02)00146-5     Document Type: Article
Times cited : (32)

References (28)
  • 1
    • 37049071011 scopus 로고
    • Simple low-cost tungsten-coil atomizer for electrothermal atomic absorption spectrometry
    • Berndt H., Schaldach G. Simple low-cost tungsten-coil atomizer for electrothermal atomic absorption spectrometry. J. Anal. At. Spectrom. 3:1988;709-712.
    • (1988) J. Anal. At. Spectrom. , vol.3 , pp. 709-712
    • Berndt, H.1    Schaldach, G.2
  • 2
    • 0000052695 scopus 로고
    • Determination of cadmium in biological materials by tungsten coil atomic absorption spectrometry
    • Giné M.F., Krug F.J., Sass V.A., Reis B.F., Nóbrega J.A., Berndt H. Determination of cadmium in biological materials by tungsten coil atomic absorption spectrometry. J. Anal. At. Spectrom. 8:1993;243-245.
    • (1993) J. Anal. At. Spectrom. , vol.8 , pp. 243-245
    • Giné, M.F.1    Krug, F.J.2    Sass, V.A.3    Reis, B.F.4    Nóbrega, J.A.5    Berndt, H.6
  • 4
    • 0001373401 scopus 로고
    • Determination of lead in blood tungsten coil electrothermal atomic absorption spectrometry
    • Krug F.J., Silva M.M., Oliveira P.V., Nóbrega J.A. Determination of lead in blood tungsten coil electrothermal atomic absorption spectrometry. Spectrochim. Acta Part B. 50:1995;1469-1474.
    • (1995) Spectrochim. Acta Part B , vol.50 , pp. 1469-1474
    • Krug, F.J.1    Silva, M.M.2    Oliveira, P.V.3    Nóbrega, J.A.4
  • 5
    • 0030402473 scopus 로고    scopus 로고
    • Separation and preconcentration by flow injection coupled to tungsten coil electrothermal atomic absorption spectrometry
    • Silva M.M., Krug F.J., Oliveira P.V., Nóbrega J.A., Reis B.F., Penteado D. Separation and preconcentration by flow injection coupled to tungsten coil electrothermal atomic absorption spectrometry. Spectrochim. Acta Part B. 51:1996;1925-1934.
    • (1996) Spectrochim. Acta Part B , vol.51 , pp. 1925-1934
    • Silva, M.M.1    Krug, F.J.2    Oliveira, P.V.3    Nóbrega, J.A.4    Reis, B.F.5    Penteado, D.6
  • 6
    • 0037045212 scopus 로고    scopus 로고
    • Electrothermal behavior of sodium, potassium, calcium and magnesium in a tungsten coil atomizer and review of interfering effects
    • Queiroz Z.F., Krug F.J., Oliveira P.V., Silva M.M., Nóbrega J.A. Electrothermal behavior of sodium, potassium, calcium and magnesium in a tungsten coil atomizer and review of interfering effects. Spectrochim. Acta Part B. 57:2002;49-61.
    • (2002) Spectrochim. Acta Part B , vol.57 , pp. 49-61
    • Queiroz, Z.F.1    Krug, F.J.2    Oliveira, P.V.3    Silva, M.M.4    Nóbrega, J.A.5
  • 7
    • 0032429001 scopus 로고    scopus 로고
    • Determination of ytterbium in animal faeces by tungsten coil electrothermal atomic absorption spectrometry
    • Lima E.C., Krug F.J., Nóbrega J.A., Nogueira A.R.A. Determination of ytterbium in animal faeces by tungsten coil electrothermal atomic absorption spectrometry. Talanta. 47:1998;613-623.
    • (1998) Talanta , vol.47 , pp. 613-623
    • Lima, E.C.1    Krug, F.J.2    Nóbrega, J.A.3    Nogueira, A.R.A.4
  • 8
    • 0344901563 scopus 로고    scopus 로고
    • Atomization of Al in a tungsten coil electrothermal atomic absorption spectrophotometer
    • Lucas P.O., Nóbrega J.A., Oliveira P.V., Krug F.J. Atomization of Al in a tungsten coil electrothermal atomic absorption spectrophotometer. Talanta. 48:1999;695-703.
    • (1999) Talanta , vol.48 , pp. 695-703
    • Lucas, P.O.1    Nóbrega, J.A.2    Oliveira, P.V.3    Krug, F.J.4
  • 9
    • 0028930406 scopus 로고
    • Analytical evaluation of a tungsten coil atomizer for cadmium, lead, chromium, manganese, nickel and cobalt determination by electrothermal atomic absorption spectrometry
    • Bruhn C.G., Ambiado F.E., Cid H.J., Woerner R., Tapia J., Garcia R. Analytical evaluation of a tungsten coil atomizer for cadmium, lead, chromium, manganese, nickel and cobalt determination by electrothermal atomic absorption spectrometry. Anal. Chim. Acta. 306:1995;183-192.
    • (1995) Anal. Chim. Acta , vol.306 , pp. 183-192
    • Bruhn, C.G.1    Ambiado, F.E.2    Cid, H.J.3    Woerner, R.4    Tapia, J.5    Garcia, R.6
  • 10
    • 0000708532 scopus 로고    scopus 로고
    • Determination of heavy metals in waters and drinks by electrothermal atomic absorption spectrometry with a tungsten coil atomizer
    • Bruhn C.G., Ambiado F.E., Cid H.J., Woerner R., Tapia J., Garcia R. Determination of heavy metals in waters and drinks by electrothermal atomic absorption spectrometry with a tungsten coil atomizer. Quím. Anal. 15:1996;191-200.
    • (1996) Quím. Anal. , vol.15 , pp. 191-200
    • Bruhn, C.G.1    Ambiado, F.E.2    Cid, H.J.3    Woerner, R.4    Tapia, J.5    Garcia, R.6
  • 11
    • 0031698860 scopus 로고    scopus 로고
    • Chemical modifiers in a tungsten coil electrothermal atomizer. Part 1. Determination of lead in hair and blood
    • Bruhn C.G., Neira J.Y., Valenzuela G.D., Nóbrega J.A. Chemical modifiers in a tungsten coil electrothermal atomizer. Part 1. Determination of lead in hair and blood. J. Anal. At. Spectrom. 13:1998;29-35.
    • (1998) J. Anal. At. Spectrom. , vol.13 , pp. 29-35
    • Bruhn, C.G.1    Neira, J.Y.2    Valenzuela, G.D.3    Nóbrega, J.A.4
  • 12
    • 0000369438 scopus 로고    scopus 로고
    • Evaluation of a modified spectrometer for electrothermal atomic absorption spectrometry with tungsten coils. Determination of chromium
    • Knochen M., Saritsky E., Dol I. Evaluation of a modified spectrometer for electrothermal atomic absorption spectrometry with tungsten coils. Determination of chromium. Quím. Anal. 15:1996;184-190.
    • (1996) Quím. Anal. , vol.15 , pp. 184-190
    • Knochen, M.1    Saritsky, E.2    Dol, I.3
  • 13
    • 0000426442 scopus 로고
    • A low-cost tungsten filament atomizer for measuring lead in blood by atomic absorption spectrometry
    • Parsons P.J., Qiao H., Aldous K.M., Mills E., Slavin W. A low-cost tungsten filament atomizer for measuring lead in blood by atomic absorption spectrometry. Spectrochim. Acta Part B. 50:1995;1475-1480.
    • (1995) Spectrochim. Acta Part B , vol.50 , pp. 1475-1480
    • Parsons, P.J.1    Qiao, H.2    Aldous, K.M.3    Mills, E.4    Slavin, W.5
  • 14
    • 0030073761 scopus 로고    scopus 로고
    • Portable, battery-powered, tungsten coil atomic absorption spectrometer for lead determinations
    • Sanford C.L., Thomas S.E., Jones B.T. Portable, battery-powered, tungsten coil atomic absorption spectrometer for lead determinations. Appl. Spectrosc. 50:1996;174-181.
    • (1996) Appl. Spectrosc. , vol.50 , pp. 174-181
    • Sanford, C.L.1    Thomas, S.E.2    Jones, B.T.3
  • 15
    • 0032139533 scopus 로고    scopus 로고
    • Determination of cadmium with a portable, battery-powered tungsten coil atomic absorption spectrometer
    • Batchelor J.D., Thomas S.E., Jones B.T. Determination of cadmium with a portable, battery-powered tungsten coil atomic absorption spectrometer. Appl. Spectrosc. 52:1998;1086-1091.
    • (1998) Appl. Spectrosc. , vol.52 , pp. 1086-1091
    • Batchelor, J.D.1    Thomas, S.E.2    Jones, B.T.3
  • 16
    • 0032148391 scopus 로고    scopus 로고
    • An electrothermal atomic absorption spectrometer using semiconductor diode lasers and a tungsten coil atomizer: Design and first applications
    • Krivan V., Barth P., Schnurer-Patschan C. An electrothermal atomic absorption spectrometer using semiconductor diode lasers and a tungsten coil atomizer: design and first applications. Anal. Chem. 70:1998;3525-3532.
    • (1998) Anal. Chem. , vol.70 , pp. 3525-3532
    • Krivan, V.1    Barth, P.2    Schnurer-Patschan, C.3
  • 17
    • 4243469735 scopus 로고
    • Electrothermal atomization from metallic surfaces. Part 3. Some new developments in design and performance of a tungsten-tube atomizer
    • Sychra V., Puschel P., Formanek Z., Hlavac R., Kolihova D. Electrothermal atomization from metallic surfaces. Part 3. Some new developments in design and performance of a tungsten-tube atomizer. Anal. Chim. Acta. 127:1981;109-120.
    • (1981) Anal. Chim. Acta , vol.127 , pp. 109-120
    • Sychra, V.1    Puschel, P.2    Formanek, Z.3    Hlavac, R.4    Kolihova, D.5
  • 18
    • 0000297384 scopus 로고    scopus 로고
    • Tungsten atomizer - Theory of atomization mechanism of some volatile analytes
    • Krakovska E., Remeteiova D. Tungsten atomizer - theory of atomization mechanism of some volatile analytes. Fresenius J. Anal. Chem. 366:2000;127-131.
    • (2000) Fresenius J. Anal. Chem. , vol.366 , pp. 127-131
    • Krakovska, E.1    Remeteiova, D.2
  • 20
    • 0001525337 scopus 로고
    • Theoretical temperature-time curves for electrically heated filament atom reservoirs. Their significance in analytical spectrometry
    • Cresser M.S., Mullins C.E. Theoretical temperature-time curves for electrically heated filament atom reservoirs. Their significance in analytical spectrometry. Anal. Chim. Acta. 68:1974;377-385.
    • (1974) Anal. Chim. Acta , vol.68 , pp. 377-385
    • Cresser, M.S.1    Mullins, C.E.2
  • 21
    • 46149138203 scopus 로고
    • Temperature of a W ribbon furnace in electrothermal atomic absorption spectrometry
    • Nakamura, Kobayashi Y., Kubota M. Temperature of a W ribbon furnace in electrothermal atomic absorption spectrometry. Spectrochim. Acta Part B. 41:1986;817-823.
    • (1986) Spectrochim. Acta Part B , vol.41 , pp. 817-823
    • Nakamura1    Kobayashi, Y.2    Kubota, M.3
  • 22
    • 0027646181 scopus 로고
    • Calibration of the drying and pyrolysis temperatures for graphite furnace atomic absorption spectrometry by direct observation of the melting of compounds
    • LaRue R.M., Tyson J.F. Calibration of the drying and pyrolysis temperatures for graphite furnace atomic absorption spectrometry by direct observation of the melting of compounds. Spectrochim. Acta Part B. 48:1993;1307-1311.
    • (1993) Spectrochim. Acta Part B , vol.48 , pp. 1307-1311
    • LaRue, R.M.1    Tyson, J.F.2
  • 24
    • 0000417473 scopus 로고
    • The temperature of atomic vapor in graphite furnace atomic absorption spectrometry
    • Sturgeon R.E., Chakrabarti C.L. The temperature of atomic vapor in graphite furnace atomic absorption spectrometry. Spectrochim. Acta Part B. 32:1977;231-255.
    • (1977) Spectrochim. Acta Part B , vol.32 , pp. 231-255
    • Sturgeon, R.E.1    Chakrabarti, C.L.2
  • 27
    • 0021421683 scopus 로고
    • Gas phase temperatures in Massmann furnaces equipped with L'vov platforms
    • Simer D.D., Lundberg E., Frech W. Gas phase temperatures in Massmann furnaces equipped with L'vov platforms. Appl. Spectrosc. 38:1984;389-391.
    • (1984) Appl. Spectrosc. , vol.38 , pp. 389-391
    • Simer, D.D.1    Lundberg, E.2    Frech, W.3
  • 28
    • 0001197233 scopus 로고
    • Temperature of platform, furnace wall and vapour and a pulse heated electrothermal graphite furnace in atomic absorption spectrometry
    • Chakrabarti C.L., Wu Shaole, Karwowska R., Rogers J.T., Haley L., Bertels P.C., Dick R. Temperature of platform, furnace wall and vapour and a pulse heated electrothermal graphite furnace in atomic absorption spectrometry. Spectrochim. Acta Part B. 39:1984;415-448.
    • (1984) Spectrochim. Acta Part B , vol.39 , pp. 415-448
    • Chakrabarti, C.L.1    Wu Shaole2    Karwowska, R.3    Rogers, J.T.4    Haley, L.5    Bertels, P.C.6    Dick, R.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.