메뉴 건너뛰기




Volumn 1, Issue , 2002, Pages 167-172

MIMO robust control for heating, ventilating and air conditioning (HVAC) systems

Author keywords

[No Author keywords available]

Indexed keywords

AIR CONDITIONING; COMPUTER SIMULATION; CONTROL SYSTEM ANALYSIS; HEATING; PERFORMANCE; TEMPERATURE CONTROL; TWO TERM CONTROL SYSTEMS; VENTILATION;

EID: 0036996168     PISSN: 01912216     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (8)

References (16)
  • 1
    • 0003628567 scopus 로고    scopus 로고
    • MIMO robust control for heating, ventilating and air conditioning (HVAC) systems
    • Masters Thesis, Colorado State University, Fort Collins, CO, Spring
    • M. L. Anderson, MIMO Robust Control for Heating, Ventilating and Air Conditioning (HVAC) Systems, Masters Thesis, Colorado State University, Fort Collins, CO, Spring 2001.
    • (2001)
    • Anderson, M.L.1
  • 6
    • 0031238192 scopus 로고    scopus 로고
    • Dynamic response and tuning
    • Sept.
    • D. C. Hittle, Dynamic Response and Tuning, ASHRAE Journal, pp. 40-43, Sept. 1997.
    • (1997) ASHRAE Journal , pp. 40-43
    • Hittle, D.C.1
  • 9
    • 0000860811 scopus 로고
    • Selecting the proportional and integral constants in the direct digital control of discharge air temperature
    • C. G. Nesler and W. F. Stoecker, Selecting the Proportional and Integral Constants in the Direct Digital Control of Discharge Air Temperature, ASHRE Transactions, vol. 90, part 2B, pp. 834-845, 1984.
    • (1984) ASHRE Transactions , vol.90 , Issue.PART 2B , pp. 834-845
    • Nesler, C.G.1    Stoecker, W.F.2
  • 10
    • 0027205718 scopus 로고
    • The complex structured singular value
    • A. Packard and J. C. Doyle, The Complex Structured Singular Value, Automatica, vol. 29, no. 1, pp. 71-109, 1993.
    • (1993) Automatica , vol.29 , Issue.1 , pp. 71-109
    • Packard, A.1    Doyle, J.C.2
  • 11
    • 0013202121 scopus 로고
    • The dynamic performance of A discharge air temperature system with A P-I controller
    • Honeywell Inc., Commercial Division, Arlington Heights, Illinois
    • G. Shaavit and S. G. Brandt, The Dynamic Performance of A Discharge Air Temperature System With A P-I Controller, Honeywell Inc., Commercial Division, Arlington Heights, Illinois, 1982.
    • (1982)
    • Shaavit, G.1    Brandt, S.G.2
  • 12
    • 0003429027 scopus 로고    scopus 로고
    • Multivariable feedback control
    • John Wiley and Sons Ltd., West Sussex, England
    • S. Skogested and I. Postlethwaite, Multivariable Feedback Control, John Wiley and Sons Ltd., West Sussex, England, 1996.
    • (1996)
    • Skogested, S.1    Postlethwaite, I.2
  • 14
    • 0030257908 scopus 로고    scopus 로고
    • Controller design with real parameteric uncertainty
    • P. M. Young, Controller Design with Real Parameteric Uncertainty, International Journal of Control, vol. 65, pp. 469-509, 1996.
    • (1996) International Journal of Control , vol.65 , pp. 469-509
    • Young, P.M.1
  • 15
    • 0027628001 scopus 로고
    • Optimal, sub-optimal and adaptive control methods for the design of temperature controllers for intelligent buildings
    • July
    • M. Zaheer-Uddin, Optimal, Sub-Optimal and Adaptive Control Methods for the Design of Temperature Controllers for Intelligent Buildings, Building and Environment, vol. 28, no. 3, pp. 311-322, July 1993.
    • (1993) Building and Environment , vol.28 , Issue.3 , pp. 311-322
    • Zaheer-Uddin, M.1
  • 16
    • 0040215093 scopus 로고    scopus 로고
    • Discharge air system: Modelling and optimal control
    • June
    • G. R. Zheng and M. Zaheer-Uddin, Discharge Air System: Modelling and Optimal Control, International Journal of Energy Research, vol. 23, no. 8, pp. 727-738. June 1999.
    • (1999) International Journal of Energy Research , vol.23 , Issue.8 , pp. 727-738
    • Zheng, G.R.1    Zaheer-Uddin, M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.