메뉴 건너뛰기




Volumn 13, Issue 12, 2002, Pages 1822-1830

The influence of permittivity models on phantom images obtained from electrical capacitance tomography

Author keywords

Electrical capacitance tomography; Fluidized bed; Image reconstruction; Iterative reconstruction; Linear back projection; Maxwell model; Parallel model; Phantom; Relative permittivity; Series model; Voidage

Indexed keywords

CAPACITANCE; CATALYSTS; FLUIDIZED BEDS; PERMITTIVITY;

EID: 0036995602     PISSN: 09570233     EISSN: None     Source Type: Journal    
DOI: 10.1088/0957-0233/13/12/304     Document Type: Article
Times cited : (64)

References (17)
  • 2
    • 0003024561 scopus 로고    scopus 로고
    • A fast iterative image reconstruction algorithm for capacitance tomography
    • Yang W Q, Gamio J C and Beck M S 1997 A fast iterative image reconstruction algorithm for capacitance tomography Sensors and their Applications vol 8 pp 47-52
    • (1997) Sensors and Their Applications , vol.8 , pp. 47-52
    • Yang, W.Q.1    Gamio, J.C.2    Beck, M.S.3
  • 3
    • 0033293594 scopus 로고    scopus 로고
    • An image-reconstruction algorithm based on Landweber's iteration method for electrical-capacitance tomography
    • Yang W Q, Spink D M, York T A and McCann H 1999 An image-reconstruction algorithm based on Landweber's iteration method for electrical-capacitance tomography Meas. Sci. Technol. 10 1065-9
    • (1999) Meas. Sci. Technol. , vol.10 , pp. 1065-1069
    • Yang, W.Q.1    Spink, D.M.2    York, T.A.3    McCann, H.4
  • 4
    • 0034739728 scopus 로고    scopus 로고
    • Applications of electrical tomography for gas-solids and liquid-solids flows - A review
    • Dyakowski T, Jeanmeure L F C and Jaworski A J 2000 Applications of electrical tomography for gas-solids and liquid-solids flows-a review Powder Technol. 112 174-92
    • (2000) Powder Technol. , vol.112 , pp. 174-192
    • Dyakowski, T.1    Jeanmeure, L.F.C.2    Jaworski, A.J.3
  • 6
    • 0034193149 scopus 로고    scopus 로고
    • Capacitance probes for solids volume concentration and velocity measurements in industrial fluidized bed reactors
    • Wiesendorf V and Werther J 2000 Capacitance probes for solids volume concentration and velocity measurements in industrial fluidized bed reactors Powder Technol. 110 143-57
    • (2000) Powder Technol. , vol.110 , pp. 143-157
    • Wiesendorf, V.1    Werther, J.2
  • 7
    • 0001782594 scopus 로고
    • Dielectric behavior of heterogeneous systems
    • van Beek L K H 1967 Dielectric behavior of heterogeneous systems Prog. Dielectrics 7 69-114
    • (1967) Prog. Dielectrics , vol.7 , pp. 69-114
    • van Beek, L.K.H.1
  • 8
    • 0033721303 scopus 로고    scopus 로고
    • The design of an electrical capacitance tomography sensor for use with media of high dielectric permittivity
    • Jaworski A J and Bolton G T 2000 The design of an electrical capacitance tomography sensor for use with media of high dielectric permittivity Meas. Sci. Technol. 11 743-57
    • (2000) Meas. Sci. Technol. , vol.11 , pp. 743-757
    • Jaworski, A.J.1    Bolton, G.T.2
  • 9
    • 0026817549 scopus 로고
    • Design of sensor electronics for electrical capacitance tomography
    • Huang S M, Xie C G, Thorn R, Snowden D and Beck M S 1992 Design of sensor electronics for electrical capacitance tomography IEE Proc. G 139 83-8
    • (1992) IEE Proc. G , vol.139 , pp. 83-88
    • Huang, S.M.1    Xie, C.G.2    Thorn, R.3    Snowden, D.4    Beck, M.S.5
  • 10
    • 0030088214 scopus 로고    scopus 로고
    • A review of reconstruction techniques for capacitance tomography
    • Isaksen O 1996 A review of reconstruction techniques for capacitance tomography Meas. Sci. Technol. 7 325-37
    • (1996) Meas. Sci. Technol. , vol.7 , pp. 325-337
    • Isaksen, O.1
  • 12
    • 0034725522 scopus 로고    scopus 로고
    • The hydrodynamics of the high-density bottom zone of a CFB riser analyzed by means of electrical capacitance tomography (ECT)
    • Malcus S, Chaplin G and Pugsley T 2000 The hydrodynamics of the high-density bottom zone of a CFB riser analyzed by means of electrical capacitance tomography (ECT) Chem. Eng. Sci. 55 4129-38
    • (2000) Chem. Eng. Sci. , vol.55 , pp. 4129-4138
    • Malcus, S.1    Chaplin, G.2    Pugsley, T.3
  • 13
    • 0029106109 scopus 로고
    • Real time capacitance imaging of bubble formation at the distributor of a fluidized bed
    • Wang S J, Dyakowski T, Xie C G, Williams R A and Beck M S 1995 Real time capacitance imaging of bubble formation at the distributor of a fluidized bed Chem. Eng. J. 56 95-100
    • (1995) Chem. Eng. J. , vol.56 , pp. 95-100
    • Wang, S.J.1    Dyakowski, T.2    Xie, C.G.3    Williams, R.A.4    Beck, M.S.5
  • 14
    • 85034788047 scopus 로고    scopus 로고
    • Calculation of volume ratio for ECT sensors
    • Process Tomography Ltd
    • Process Tomography Ltd 1999 Calculation of volume ratio for ECT sensors PTL Application Note AN2
    • (1999) PTL Application Note AN2
  • 15
    • 0025464535 scopus 로고
    • Measurements of the effective dielectric permittivity of suspensions
    • Louge M and Opie M 1990 Measurements of the effective dielectric permittivity of suspensions Powder Technol. 62 85-94
    • (1990) Powder Technol. , vol.62 , pp. 85-94
    • Louge, M.1    Opie, M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.