메뉴 건너뛰기




Volumn 16, Issue 8, 2002, Pages 541-548

The single-plasma-sample method for determining the glomerular filtration rate with Tc-99m-diethylenetriamine pentaacetic acid in childhood and adolescence: Is it age-dependent?

Author keywords

Children; Glomerular filtration rate; Plasma clearance; Tc 99m DTPA

Indexed keywords

PENTETATE TECHNETIUM TC 99M;

EID: 0036993570     PISSN: 09147187     EISSN: None     Source Type: Journal    
DOI: 10.1007/BF02988631     Document Type: Article
Times cited : (4)

References (29)
  • 1
    • 85038528267 scopus 로고
    • 99mTc-DTPA clearance by single plasma sample method
    • 99mTc-DTPA clearance by single plasma sample method. Clin Physiol 1989; 6: 576-588.
    • (1989) Clin Physiol , vol.6 , pp. 576-588
    • Christensen, A.B.1    Groth, S.2
  • 2
    • 0026494261 scopus 로고
    • A simple method of estimating glomerular filtration rate
    • letters to the editor
    • Watson WS. A simple method of estimating glomerular filtration rate. [letters to the editor] Eur J Nucl Med 1992; 19: 827.
    • (1992) Eur J Nucl Med , vol.19 , pp. 827
    • Watson, W.S.1
  • 3
    • 0020955393 scopus 로고
    • A method for the calculation of renal determination by one plasma sample
    • Jacobsson L. A method for the calculation of renal determination by one plasma sample. Clin Physiol 1981; 3: 297-305.
    • (1981) Clin Physiol , vol.3 , pp. 297-305
    • Jacobsson, L.1
  • 5
    • 0015387619 scopus 로고
    • Estimation of glomerular filtration rate measurement from plasma clearance of 51-chronium editic acid
    • Chantler C, Barratt TM. Estimation of glomerular filtration rate measurement from plasma clearance of 51-chronium editic acid. Arch Dis Child 1972; 47: 613-617.
    • (1972) Arch Dis Child , vol.47 , pp. 613-617
    • Chantler, C.1    Barratt, T.M.2
  • 6
    • 0021288699 scopus 로고
    • 51Cr-EDTA clearance determined by one plasma sample in children
    • 51Cr-EDTA clearance determined by one plasma sample in children. Clin Physiol 1984; 4: 75-83.
    • (1984) Clin Physiol , vol.4 , pp. 75-83
    • Groth, S.1    Aasted, M.2
  • 7
    • 0025887186 scopus 로고
    • Estimation of glomerular filtration rate in infants and in children using a single-plasma sample method
    • Ham HR, Piepsz A. Estimation of glomerular filtration rate in infants and in children using a single-plasma sample method. J Nucl Med 1991; 32: 1294-1297.
    • (1991) J Nucl Med , vol.32 , pp. 1294-1297
    • Ham, H.R.1    Piepsz, A.2
  • 8
    • 0013561038 scopus 로고
    • Reply to Peters
    • letters to the editor
    • Ham HR, Piepsz A. Reply to Peters. [letters to the editor] J Nucl Med 1992; 33: 174.
    • (1992) J Nucl Med , vol.33 , pp. 174
    • Ham, H.R.1    Piepsz, A.2
  • 9
    • 0029998582 scopus 로고    scopus 로고
    • Report of the Radionuclides in Nephrourology Committee on renal clearance
    • Blaufox MD, Aurell M, Bubeck B, Fommei E, Piepsz A, Russell C, et al. Report of the Radionuclides in Nephrourology Committee on renal clearance. J Nucl Med 1996; 37: 1883-1890.
    • (1996) J Nucl Med , vol.37 , pp. 1883-1890
    • Blaufox, M.D.1    Aurell, M.2    Bubeck, B.3    Fommei, E.4    Piepsz, A.5    Russell, C.6
  • 11
    • 0030640438 scopus 로고    scopus 로고
    • Evaluation of single sample clearance calculation in 902 patients
    • Lundqvist S, Hietala S-O, Groth S, Sjodin J-D. Evaluation of single sample clearance calculation in 902 patients. Acta Radiol 1997; 38: 68-72.
    • (1997) Acta Radiol , vol.38 , pp. 68-72
    • Lundqvist, S.1    Hietala, S.-O.2    Groth, S.3    Sjodin, J.-D.4
  • 12
    • 0030932604 scopus 로고    scopus 로고
    • Use of iohexol to determine glomerular filtration rate. A comparison between different clearance techniques in man and animal
    • Fennby B. Use of iohexol to determine glomerular filtration rate. A comparison between different clearance techniques in man and animal. Scan J Urol Nephrol 1997; 31 (Suppl 182): 1-63.
    • (1997) Scan J Urol Nephrol , vol.31 , Issue.SUPPL. 182 , pp. 1-63
    • Fennby, B.1
  • 13
    • 0029914070 scopus 로고    scopus 로고
    • Feasibility of estimating glomerular filtration rate on children using single-sample adult technique
    • Ham HR, Piepsz A. Feasibility of estimating glomerular filtration rate on children using single-sample adult technique. J Nucl Med 1996; 37: 1805-1808.
    • (1996) J Nucl Med , vol.37 , pp. 1805-1808
    • Ham, H.R.1    Piepsz, A.2
  • 14
    • 0026648216 scopus 로고
    • A new principle to normalize plasma concentrations allowing single-sample clearance determinations in both children and adults
    • Bubeck B, Piepenburg R, Grethe U, Ehrig B, Hahn K. A new principle to normalize plasma concentrations allowing single-sample clearance determinations in both children and adults. Eur J Nucl Med 1992; 19: 511-516.
    • (1992) Eur J Nucl Med , vol.19 , pp. 511-516
    • Bubeck, B.1    Piepenburg, R.2    Grethe, U.3    Ehrig, B.4    Hahn, K.5
  • 15
    • 0030116706 scopus 로고    scopus 로고
    • Measurement of renal function with technetium-99m-MAG3 in children and adults
    • Russell CD, Tayler AT, Dubovsky EV. Measurement of renal function with technetium-99m-MAG3 in children and adults. J Nucl Med 1996; 37: 588-593.
    • (1996) J Nucl Med , vol.37 , pp. 588-593
    • Russell, C.D.1    Tayler, A.T.2    Dubovsky, E.V.3
  • 16
    • 0034792088 scopus 로고    scopus 로고
    • Determination of glomerular filtration rate by means of newly developed plastic scintillation counter both with and without dilution procedures
    • Itoh K. Determination of glomerular filtration rate by means of newly developed plastic scintillation counter both with and without dilution procedures. J Nucl Med 2001; 42: 1484-1488.
    • (2001) J Nucl Med , vol.42 , pp. 1484-1488
    • Itoh, K.1
  • 17
    • 0000625651 scopus 로고
    • Volumes of distribution and clearances of intravenously injected creatinine in the dog
    • Sapirstein LA, Vidt DG, Mandel MJ, Hanusek G. Volumes of distribution and clearances of intravenously injected creatinine in the dog. Am J Physiol 1955; 181; 330-336.
    • (1955) Am J Physiol , vol.181 , pp. 330-336
    • Sapirstein, L.A.1    Vidt, D.G.2    Mandel, M.J.3    Hanusek, G.4
  • 19
    • 0017864678 scopus 로고
    • Geometric method for measuring body surface area: A height-weight formula validated in infants, children and adults
    • Haycock GB, Schwartz GJ, Wisotsky DH. Geometric method for measuring body surface area: a height-weight formula validated in infants, children and adults. J Pediatrics 1978; 93: 62-66.
    • (1978) J Pediatrics , vol.93 , pp. 62-66
    • Haycock, G.B.1    Schwartz, G.J.2    Wisotsky, D.H.3
  • 20
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; i: 307-310.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 21
    • 0015953028 scopus 로고
    • Radionuclide clearance techniques
    • Cohen ML. Radionuclide clearance techniques. Semin Nucl Med 1974; 4: 23-38.
    • (1974) Semin Nucl Med , vol.4 , pp. 23-38
    • Cohen, M.L.1
  • 22
    • 0024851927 scopus 로고
    • Use of glomerular filtration rate measurement to assess the progression of renal disease
    • Levey AS. Use of glomerular filtration rate measurement to assess the progression of renal disease. Semin Nephrol 1989; 9: 370-379.
    • (1989) Semin Nephrol , vol.9 , pp. 370-379
    • Levey, A.S.1
  • 23
    • 0016052419 scopus 로고
    • A simple method for accurate assessment of the glomerular filtration rate in children
    • Brochner-Mortensen J, Haahr J, Christoffersen J. A simple method for accurate assessment of the glomerular filtration rate in children. Scand J Clin Lab Invest 1974; 33: 139-143.
    • (1974) Scand J Clin Lab Invest , vol.33 , pp. 139-143
    • Brochner-Mortensen, J.1    Haahr, J.2    Christoffersen, J.3
  • 24
    • 0032940833 scopus 로고    scopus 로고
    • Body surface area correction in single-sample method of glomerular filtration rate estimation
    • Hamilton D, Miola UJ. Body surface area correction in single-sample method of glomerular filtration rate estimation. Nucl Med Commun 1999; 20: 273-278.
    • (1999) Nucl Med Commun , vol.20 , pp. 273-278
    • Hamilton, D.1    Miola, U.J.2
  • 27
    • 0028202750 scopus 로고
    • Normalization of glomerular filtration rate in children: Body surface area, body-weight or extracellular fluid volume?
    • Peters AM, Gordon I, Sixt R. Normalization of glomerular filtration rate in children: body surface area, body-weight or extracellular fluid volume? J Nucl Med 1994; 35: 438-444.
    • (1994) J Nucl Med , vol.35 , pp. 438-444
    • Peters, A.M.1    Gordon, I.2    Sixt, R.3
  • 28
    • 0025775795 scopus 로고
    • Glomerular filtration rate in children: Where we have been; Where we are going
    • Editorial
    • Shore RM. Glomerular filtration rate in children: where we have been; where we are going. [Editorial] J Nucl Med 1991; 32: 1297-1300.
    • (1991) J Nucl Med , vol.32 , pp. 1297-1300
    • Shore, R.M.1
  • 29
    • 0013290689 scopus 로고
    • Current status on assessment and measurement of glomerular filtration rate
    • Brochner-Mortensen J. Current status on assessment and measurement of glomerular filtration rate. Clin Physiol 1983; 8; 1-17.
    • (1983) Clin Physiol , vol.8 , pp. 1-17
    • Brochner-Mortensen, J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.