메뉴 건너뛰기




Volumn 1, Issue , 2002, Pages 625-628

Relationship between skin-collagen micro-architecture and ultrasonic backscatter parameters at 20 MHz

Author keywords

[No Author keywords available]

Indexed keywords

ACOUSTIC WAVE BACKSCATTERING; COLLAGEN; DATA ACQUISITION; HISTOLOGY; MEDICAL IMAGING; MICROSCOPIC EXAMINATION; SKIN; SPECTRUM ANALYSIS; ULTRASONIC MEASUREMENT; ULTRASONIC TRANSDUCERS;

EID: 0036992319     PISSN: 10510117     EISSN: None     Source Type: Journal    
DOI: 10.1109/ULTSYM.2002.1193480     Document Type: Article
Times cited : (3)

References (7)
  • 1
    • 0031261499 scopus 로고    scopus 로고
    • Value of high-frequency US for preoperative assessment of skin tumors
    • N. Lassau, et al., “Value of high-frequency US for preoperative assessment of skin tumors,” RadioGraphics, vol.17, pp. 1559-1565, 1997.
    • (1997) RadioGraphics , vol.17 , pp. 1559-1565
    • Lassau, N.1
  • 2
    • 0026690863 scopus 로고
    • High-resolution real-time ultrasonic scanner
    • M. Berson, et al., “High-resolution real-time ultrasonic scanner,” Ultrasound Med Biol, vol. 18, pp. 471-478, 1992.
    • (1992) Ultrasound Med Biol , vol.18 , pp. 471-478
    • Berson, M.1
  • 3
    • 0035012967 scopus 로고    scopus 로고
    • Reproducibility of skin characterization with backscattered spectra (12-25 MHz) in healthy subjects
    • C. Fournier, et al., “Reproducibility of skin characterization with backscattered spectra (12-25 MHz) in healthy subjects,” Ultrasound Med Biol, vol. 27, pp. 603-610, 2001.
    • (2001) Ultrasound Med Biol , vol.27 , pp. 603-610
    • Fournier, C.1
  • 4
    • 0019398237 scopus 로고
    • Dependence of the ultrasonic scatter coefficient on collagen concentration in mammalian tissues
    • J. Pohlhammer and W.D. O’Brien, “Dependence of the ultrasonic scatter coefficient on collagen concentration in mammalian tissues,” J Acoust Soc Am, vol. 69, pp. 283-285, 1981.
    • (1981) J Acoust Soc Am , vol.69 , pp. 283-285
    • Pohlhammer, J.1    O’Brien, W.D.2
  • 5
    • 0030241004 scopus 로고    scopus 로고
    • Absolute backscatter coefficient over a wide range of frequencies in a tissue-mimicking phantom containing two populations of scatterers
    • V. Roberjot, et al., “Absolute backscatter coefficient over a wide range of frequencies in a tissue-mimicking phantom containing two populations of scatterers,” IEEE Trans UFFC, vol. 43, pp. 970-978, 1996.
    • (1996) IEEE Trans UFFC , vol.43 , pp. 970-978
    • Roberjot, V.1
  • 6
    • 0001416258 scopus 로고
    • Texture analysis using gray level run lengths
    • M.M. Galloway, “Texture analysis using gray level run lengths,” Computer Graphics and Image Processing, vol. 4, pp. 172-179, 1975.
    • (1975) Computer Graphics and Image Processing , vol.4 , pp. 172-179
    • Galloway, M.M.1
  • 7
    • 0028216929 scopus 로고
    • Ultrasound scattering from blood with hematocrits up to 100%
    • L.Y.L. Mo, et al., “Ultrasound scattering from blood with hematocrits up to 100%,” IEEE Trans Biomed Eng, vol. 41, pp. 91-95, 1994.
    • (1994) IEEE Trans Biomed Eng , vol.41 , pp. 91-95
    • Mo, L.Y.L.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.