-
1
-
-
0024535244
-
Increasing incidence of aortic aneurysms in England and Wales
-
Fowkes FGR, Macintyre CCA, Ruckley CV. Increasing incidence of aortic aneurysms in England and Wales. Br Med J 1989; 298: 33-35.
-
(1989)
Br Med J
, vol.298
, pp. 33-35
-
-
Fowkes, F.G.R.1
Macintyre, C.C.A.2
Ruckley, C.V.3
-
2
-
-
0034122609
-
Population screening reduces mortality rates from aortic aneurysms in men
-
Heather BP, Poskitt KR, Earnshaw JJ et al. Population screening reduces mortality rates from aortic aneurysms in men. Br J Surg 2000; 87: 750-53.
-
(2000)
Br J Surg
, vol.87
, pp. 750-753
-
-
Heather, B.P.1
Poskitt, K.R.2
Earnshaw, J.J.3
-
3
-
-
0035350686
-
Functional outcome after open repair of abdominal aortic aneurysm
-
Williamson WK, Nicolof AD, Taylor LM et al. Functional outcome after open repair of abdominal aortic aneurysm. J Vasc Surg 2001; 33: 913-20.
-
(2001)
J Vasc Surg
, vol.33
, pp. 913-920
-
-
Williamson, W.K.1
Nicolof, A.D.2
Taylor, L.M.3
-
4
-
-
0026321992
-
Transfemoral intraluminal graft implantation for abdominal aortic aneurysm
-
Parodi JC, Palmaz JC, Barone HD. Transfemoral intraluminal graft implantation for abdominal aortic aneurysm. Ann Vasc Surg 1991; 5: 491-99.
-
(1991)
Ann Vasc Surg
, vol.5
, pp. 491-499
-
-
Parodi, J.C.1
Palmaz, J.C.2
Barone, H.D.3
-
5
-
-
0032556493
-
Mortality results for a randomised controlled trial of early elective surgery, or ultrasonographic surveillance for small abdominal aortic aneurysms
-
The UK Small Aneurysm Trial Participants. Mortality results for a randomised controlled trial of early elective surgery, or ultrasonographic surveillance for small abdominal aortic aneurysms. Lancet 1998; 352: 1656-60.
-
(1998)
Lancet
, vol.352
, pp. 1656-1660
-
-
-
6
-
-
0003241042
-
The Department of Veterans Affairs aneurysm detection and management (ADAM) study
-
Lederle FA, Wilson SE, Johnson GR. The Department of Veterans Affairs aneurysm detection and management (ADAM) study. Circulation 2000; 102: 2672c.
-
(2000)
Circulation
, vol.102
-
-
Lederle, F.A.1
Wilson, S.E.2
Johnson, G.R.3
-
7
-
-
0035668979
-
Portsmouth POSSUM models for abdominal aortic aneurysm surgery
-
Prytherch DR, Sutton GL, Boyle JR. Portsmouth POSSUM models for abdominal aortic aneurysm surgery. Br J Surg 2001; 88: 958-63.
-
(2001)
Br J Surg
, vol.88
, pp. 958-963
-
-
Prytherch, D.R.1
Sutton, G.L.2
Boyle, J.R.3
-
8
-
-
0027967327
-
Non ruptured abdominal aortic aneurysm 6 year follow up. Results from the multicentre Canadian aneurysm study
-
Johnston KW. Non ruptured abdominal aortic aneurysm 6 year follow up. Results from the multicentre Canadian aneurysm study. J Vasc Surg 1994; 20: 163-72.
-
(1994)
J Vasc Surg
, vol.20
, pp. 163-172
-
-
Johnston, K.W.1
-
9
-
-
0034235568
-
Comparison of first and second generation prostheses for endoluminal repair of abdominal aortic aneurysms. A 6 year study with life table analysis
-
May J, White GH, Waugh R et al. Comparison of first and second generation prostheses for endoluminal repair of abdominal aortic aneurysms. A 6 year study with life table analysis. J Vasc Surg 2000; 32: 124-29.
-
(2000)
J Vasc Surg
, vol.32
, pp. 124-129
-
-
May, J.1
White, G.H.2
Waugh, R.3
-
10
-
-
0034596498
-
Endovascular stenting of abdominal aortic aneurysms in patients unfit for open elective surgery
-
Eurostar Group. Endovascular stenting of abdominal aortic aneurysms in patients unfit for open elective surgery. Lancet 2000; 356: 832.
-
(2000)
Lancet
, vol.356
, pp. 832
-
-
-
11
-
-
0032885844
-
Mortality rates following endovascular repair of abdominal aortic aneurysms
-
Walker SR, Macierewicz J, MacSweeney ST et al. Mortality rates following endovascular repair of abdominal aortic aneurysms. J Endovasc Surg 1999; 6: 233-38.
-
(1999)
J Endovasc Surg
, vol.6
, pp. 233-238
-
-
Walker, S.R.1
Macierewicz, J.2
MacSweeney, S.T.3
-
12
-
-
0033023672
-
Frame dislocation of body middle rings in endovascular stent tube grafts
-
Riepe G, Heilbergr P, Umscheid T et al. Frame dislocation of body middle rings in endovascular stent tube grafts. Eur J Vasc Endovasc Surg 1999; 17: 28-34.
-
(1999)
Eur J Vasc Endovasc Surg
, vol.17
, pp. 28-34
-
-
Riepe, G.1
Heilbergr, P.2
Umscheid, T.3
-
13
-
-
0034042336
-
Aneurysm rupture after endovascular repair using the AneuRx stent graft
-
Zanns GK, White RA, Fogarty TJ. Aneurysm rupture after endovascular repair using the AneuRx stent graft. J Vasc Surg 2000; 31: 960-70.
-
(2000)
J Vasc Surg
, vol.31
, pp. 960-970
-
-
Zanns, G.K.1
White, R.A.2
Fogarty, T.J.3
-
14
-
-
0034144603
-
Dilatation of the proximal neck of infrarenal aortic aneurysms after AAA repair
-
Wever JJ, De Nie AJ, Blankensteijn JD et al. Dilatation of the proximal neck of infrarenal aortic aneurysms after AAA repair. Eur J Vasc Endovasc Surg 2000; 19: 197-201.
-
(2000)
Eur J Vasc Endovasc Surg
, vol.19
, pp. 197-201
-
-
Wever, J.J.1
De Nie, A.J.2
Blankensteijn, J.D.3
-
15
-
-
0002212578
-
Poor stent graft incorporation in human aortas
-
Malina M, Lindblatt B, Ivancev K. Poor stent graft incorporation in human aortas. J Endovasc Surg 1998; 5: suppl 1: 1-19.
-
(1998)
J Endovasc Surg
, vol.5
, Issue.SUPPL. 1
, pp. 1-19
-
-
Malina, M.1
Lindblatt, B.2
Ivancev, K.3
-
16
-
-
0035405825
-
Endoleak after endovascular repair of abdominal aortic aneurysms
-
Chuter TA, Faruqi RM, Sawhney R et al. Endoleak after endovascular repair of abdominal aortic aneurysms. J Vasc Surg 2001; 34: 98-105.
-
(2001)
J Vasc Surg
, vol.34
, pp. 98-105
-
-
Chuter, T.A.1
Faruqi, R.M.2
Sawhney, R.3
-
17
-
-
0032061766
-
Type I and type II endoleaks. A more useful classification for reporting results of endoluminal AAA repair
-
White GH, May J, Waugh RC et al. Type I and type II endoleaks. A more useful classification for reporting results of endoluminal AAA repair. J Endovasc Surg 1998; 5: 189-91.
-
(1998)
J Endovasc Surg
, vol.5
, pp. 189-191
-
-
White, G.H.1
May, J.2
Waugh, R.C.3
-
18
-
-
0035489324
-
Embolisation of type 2 endoleaks after aortic stent graft implantation: Technique and immediate results
-
Haulon S, Abdelhakim T, Willsteaux S et al. Embolisation of type 2 endoleaks after aortic stent graft implantation: Technique and immediate results. J Vasc Surg 2001; 34: 600-606.
-
(2001)
J Vasc Surg
, vol.34
, pp. 600-606
-
-
Haulon, S.1
Abdelhakim, T.2
Willsteaux, S.3
-
19
-
-
0031647176
-
Type III and type IV endoleaks towards a complete definition of blood flow in the sac after endoluminal AAA repair
-
White GH, May J, Waugh RC et al. Type III and type IV endoleaks towards a complete definition of blood flow in the sac after endoluminal AAA repair. J Endovasc Surg 1998; 5: 305-309.
-
(1998)
J Endovasc Surg
, vol.5
, pp. 305-309
-
-
White, G.H.1
May, J.2
Waugh, R.C.3
-
20
-
-
0033782683
-
The Eurostar experience. Incidence and risk factors of late rupture conversion and death after endovascular repair of infrarenal aortic aneurysms
-
Harris PL, Vallabhaneni SR, Desgranges P et al. The Eurostar experience. Incidence and risk factors of late rupture conversion and death after endovascular repair of infrarenal aortic aneurysms. J Vasc Surg 2000; 32: 739-49.
-
(2000)
J Vasc Surg
, vol.32
, pp. 739-749
-
-
Harris, P.L.1
Vallabhaneni, S.R.2
Desgranges, P.3
-
21
-
-
0033841326
-
Which factors increase the risk of conversion to open surgery following endovascular abdominal aneurysm repair?
-
Eurostar Collaborators. Which factors increase the risk of conversion to open surgery following endovascular abdominal aneurysm repair? J Vasc Endovasc Surg 2000; 20: 183-89.
-
(2000)
J Vasc Endovasc Surg
, vol.20
, pp. 183-189
-
-
-
22
-
-
0034016416
-
The abdominal aortic aneurysm sac after endoluminal exclusion: A medium term morphologic follow up based on volumetric technology
-
Singh-Ranger R, McArthur T, Corte MD, Lees W, Adiseshiah M. The abdominal aortic aneurysm sac after endoluminal exclusion: A medium term morphologic follow up based on volumetric technology. J Vasc Surg 2000; 31: 490-500.
-
(2000)
J Vasc Surg
, vol.31
, pp. 490-500
-
-
Singh-Ranger, R.1
McArthur, T.2
Corte, M.D.3
Lees, W.4
Adiseshiah, M.5
-
23
-
-
0034112946
-
Comparison of cognitive function and quality of life after endovascular or conventional aortic aneurysm repair
-
Lloyd AJ, Boyle J, Bell PRF et al. Comparison of cognitive function and quality of life after endovascular or conventional aortic aneurysm repair. Br J Surg 2000; 87: 443-47.
-
(2000)
Br J Surg
, vol.87
, pp. 443-447
-
-
Lloyd, A.J.1
Boyle, J.2
Bell, P.R.F.3
-
24
-
-
0034235049
-
An evaluation of the costs to health care institutions of endovascular aortic aneurysm repair
-
Clair DG, Gray B, O'Hara PJ et al. An evaluation of the costs to health care institutions of endovascular aortic aneurysm repair. J Vasc Surg 2000; 32: 148-52.
-
(2000)
J Vasc Surg
, vol.32
, pp. 148-152
-
-
Clair, D.G.1
Gray, B.2
O'Hara, P.J.3
-
25
-
-
0035403254
-
Ruptured abdominal aortic aneurysms. The excessive mortality rate of conventional repair
-
Noel AA, Gloviczki P, Cherry KJ et al. Ruptured abdominal aortic aneurysms. The excessive mortality rate of conventional repair. J Vasc Surg 2001; 34: 41-47.
-
(2001)
J Vasc Surg
, vol.34
, pp. 41-47
-
-
Noel, A.A.1
Gloviczki, P.2
Cherry, K.J.3
-
26
-
-
0029143771
-
Influence of screening on the incidence of ruptured abdominal aortic aneurysm: 5 year results of a randomised controlled study
-
Scott RA, Wilson NM, Ashton HA. Influence of screening on the incidence of ruptured abdominal aortic aneurysm: 5 year results of a randomised controlled study. Br J Surg 1995; 82: 1066-70.
-
(1995)
Br J Surg
, vol.82
, pp. 1066-1070
-
-
Scott, R.A.1
Wilson, N.M.2
Ashton, H.A.3
-
27
-
-
0034486872
-
Newer developments in endovascular graft treatment for aortic and aorto iliac aneurysms
-
Veith FJ, Ohki T. Newer developments in endovascular graft treatment for aortic and aorto iliac aneurysms. J Cardiovasc Surg 2000; 41: 869-70.
-
(2000)
J Cardiovasc Surg
, vol.41
, pp. 869-870
-
-
Veith, F.J.1
Ohki, T.2
|