  • 1
    • 0013050380 scopus 로고    scopus 로고
    • Detector requirements for the european spallation source ESS
    • this conference
    • B. Gebauer, "Detector Requirements for the European Spallation Source ESS", this conference
    • Gebauer, B.1
  • 4
    • 0013142469 scopus 로고    scopus 로고
    • Research and Technology Development Network TECHNI (Technology for Neutron Instrumentation), Coordinator: M. Johnson, RAL, U.K
    • Research and Technology Development Network TECHNI (Technology for Neutron Instrumentation), Coordinator: M. Johnson, RAL, U.K, http://www.isis.rl.ac.uk/TECHNI
  • 5
    • 0013148283 scopus 로고    scopus 로고
    • Fraunhofer Institut Schicht- und Oberflächentechnik, 38108 Braunschweig, Germany
    • Fraunhofer Institut Schicht- und Oberflächentechnik, 38108 Braunschweig, Germany
  • 6
    • 0013137509 scopus 로고    scopus 로고
    • IMT AG, 8606 Nänikon, Schweiz
    • IMT AG, 8606 Nänikon, Schweiz; http://www.imtag.ch
  • 7
    • 0031166147 scopus 로고    scopus 로고
    • 157Gd/CsI-converters and micro-strip gas chambers with low-pressure, two-stage amplification and delay line readout
    • 157Gd/CsI-converters and micro-strip gas chambers with low-pressure, two-stage amplification and delay line readout", Nucl. Instr. and Meth. A 392 (1997) 68
    • (1997) Nucl. Instr. and Meth. A , vol.392 , pp. 68
    • Gebauer, B.1    Schulz, Ch.2    Wilpert, Th.3
  • 8
    • 0032064882 scopus 로고    scopus 로고
    • Large-area low-pressure micro-strip gas chambers for thermal neutron imaging
    • B. Gebauer et al., "Large-area low-pressure micro-strip gas chambers for thermal neutron imaging", Nucl. Instr. and Meth A 409 (1998) 56
    • (1998) Nucl. Instr. and Meth A , vol.409 , pp. 56
    • Gebauer, B.1
  • 10
    • 0013050954 scopus 로고    scopus 로고
    • Development of a hybrid MSGC detector for thermal neutron imaging with a MHz data acquisition and histogramming system
    • B. Gebauer et al., "Development of a hybrid MSGC detector for thermal neutron imaging with a MHz data acquisition and histogramming system", Proc. of the Imaging 2000 Conference, Nucl. Instr. and Meth. A 471 (2001) 249
    • (2001) Proc. of the Imaging 2000 Conference, Nucl. Instr. and Meth. A , vol.471 , pp. 249
    • Gebauer, B.1
  • 11
    • 0028543154 scopus 로고
    • Thermal neutron imaging detectors combining novel composite foil converters and gaseous electron multipliers
    • V. Dangendorf et al., "Thermal neutron imaging detectors combining novel composite foil converters and gaseous electron multipliers", Nucl. Instr. and Meth A 350 (1994) 503
    • (1994) Nucl. Instr. and Meth A , vol.350 , pp. 503
    • Dangendorf, V.1
  • 12
    • 0028456799 scopus 로고
    • On the two-stage operation mechanism of low-pressure microstrip gas chambers
    • A. Breskin et al., "On the two-stage operation mechanism of low-pressure microstrip gas chambers", Nucl. Instr. and Meth A 345 (1994) 205
    • (1994) Nucl. Instr. and Meth A , vol.345 , pp. 205
    • Breskin, A.1
  • 13
    • 0028464730 scopus 로고
    • A low-pressure, micro-strip gas chamber operated with secondary-electron emission
    • D.F. Anderson et al., "A low-pressure, micro-strip gas chamber operated with secondary-electron emission", Nucl. Instr. and Meth A 346 (1994) 102
    • (1994) Nucl. Instr. and Meth A , vol.346 , pp. 102
    • Anderson, D.F.1
  • 14
    • 0027594031 scopus 로고
    • The electrostatic field in microstrip chambers and its influence on detector performance
    • J.J. Florent et al., "The electrostatic field in microstrip chambers and its influence on detector performance", Nucl. Instr. and Meth A 329 (1993) 125
    • (1993) Nucl. Instr. and Meth A , vol.329 , pp. 125
    • Florent, J.J.1
  • 15
  • 16
    • 0013051132 scopus 로고    scopus 로고
    • Dr. Thesis, Freie Universität Berlin, Germany, Dec.
    • Ch. Schulz, Dr. Thesis, Freie Universität Berlin, Germany, Dec. 1999
    • (1999)
    • Schulz, Ch.1
  • 17
    • 0026984588 scopus 로고
    • High rate, high resolution, two-dimensional gas proportional detectors for X-ray synchrotron radiation experiments
    • G. C. Smith et al., "High rate, high resolution, two-dimensional gas proportional detectors for X-ray synchrotron radiation experiments", Nucl. Instr. and Meth A 323 (1992) 78 and references therein
    • (1992) Nucl. Instr. and Meth A , vol.323 , pp. 78
    • Smith, G.C.1
  • 18
    • 0013098684 scopus 로고    scopus 로고
    • acam-messelectronic gmbh, 76131 Karlsruhe, Germany
    • acam-messelectronic gmbh, 76131 Karlsruhe, Germany; http://www.acam.de
  • 19
    • 0013050384 scopus 로고    scopus 로고
    • Texas Instruments
    • Texas Instruments, http://ti.com