메뉴 건너뛰기




Volumn 17, Issue 4, 2002, Pages 445-452

Enhancement of transient stability of an industrial cogeneration system with superconducting magnetic energy storage unit

Author keywords

Cogeneration; Superconducting magnetic energy storage; Transient stability

Indexed keywords

ELECTRIC FAULT CURRENTS; ELECTRIC LOADS; ENERGY STORAGE; FEEDBACK; SUPERCONDUCTING MAGNETS; TRANSIENTS;

EID: 0036966550     PISSN: 08858969     EISSN: None     Source Type: Journal    
DOI: 10.1109/TEC.2002.805217     Document Type: Article
Times cited : (24)

References (11)
  • 1
    • 0031142608 scopus 로고    scopus 로고
    • The load shedding scheme design for an integrated steelmaking cogeneration facility
    • May/June
    • C. T. Hsu, C. S. Chen, and J. K. Chen, "The load shedding scheme design for an integrated steelmaking cogeneration facility," IEEE Trans. Ind. Applicat., vol. 33, pp. 586-592, May/June 1997.
    • (1997) IEEE Trans. Ind. Applicat. , vol.33 , pp. 586-592
    • Hsu, C.T.1    Chen, C.S.2    Chen, J.K.3
  • 2
    • 0017868291 scopus 로고
    • 30-MJ superconducting magnetic energy storage (SMES) unit for stabilizing an electric transmission system
    • J. D. Rogers, H. J. Boenig, J. C. Bronson, and D. B. Colyer, "30-MJ superconducting magnetic energy storage (SMES) unit for stabilizing an electric transmission system," IEEE Trans. Magn.,vol. MAG-15, pp. 820-830, 1979.
    • (1979) IEEE Trans. Magn. , vol.MAG-15 , pp. 820-830
    • Rogers, J.D.1    Boenig, H.J.2    Bronson, J.C.3    Colyer, D.B.4
  • 3
    • 0028734090 scopus 로고
    • Damping subsynchronous resonance using superconducting magnetic energy storage unit
    • Dec.
    • L. Wang, S. M. Lee, and C. L. Huang, "Damping subsynchronous resonance using superconducting magnetic energy storage unit," IEEE Trans. Energy Conversion, vol. 9, pp. 770-777, Dec. 1994.
    • (1994) IEEE Trans. Energy Conversion , vol.9 , pp. 770-777
    • Wang, L.1    Lee, S.M.2    Huang, C.L.3
  • 4
    • 0027560304 scopus 로고
    • Fuzzy control of SMES for levelling load power fluctuation based on Lukasiewicz logic
    • S. Funabiki and T. Fujii, "Fuzzy control of SMES for levelling load power fluctuation based on Lukasiewicz logic," Proc. Inst. Elect. Eng. C, vol. 140, no. 2, pp. 91-95, 1993.
    • (1993) Proc. Inst. Elect. Eng. C , vol.140 , Issue.2 , pp. 91-95
    • Funabiki, S.1    Fujii, T.2
  • 5
    • 0030107320 scopus 로고    scopus 로고
    • The power regulation of a PWM type superconducting magnetic energy storage unit
    • Mar.
    • Q. Jiang and M. F. Conlon, "The power regulation of a PWM type superconducting magnetic energy storage unit," IEEE Trans. Energy Conversion, vol. 11, pp. 168-174, Mar. 1996.
    • (1996) IEEE Trans. Energy Conversion , vol.11 , pp. 168-174
    • Jiang, Q.1    Conlon, M.F.2
  • 7
    • 84863943177 scopus 로고
    • Computer representation of excitation systems
    • June
    • "Computer representation of excitation systems," IEEE Trans. Power App. Syst., vol. PAS-84, June 1968.
    • (1968) IEEE Trans. Power App. Syst. , vol.PAS-84
  • 8
    • 0015680921 scopus 로고
    • Dynamic models for steam and hydro turbines in power system studies
    • Nov./Dec.
    • "Dynamic models for steam and hydro turbines in power system studies," IEEE Trans. Power App. Syst., vol. PAS-89, Nov./Dec. 1973.
    • (1973) IEEE Trans. Power App. Syst. , vol.PAS-89
  • 9
    • 0027595243 scopus 로고
    • Load representation for dynamic performance analysis
    • May
    • _, "Load representation for dynamic performance analysis," IEEE Trans. Power Systems, vol. 8, pp. 472-482, May 1993.
    • (1993) IEEE Trans. Power Systems , vol.8 , pp. 472-482
  • 11
    • 0004170658 scopus 로고    scopus 로고
    • CYME Int. Inc., QC, Canada
    • CYMSTAB User Guide, CYME Int. Inc., QC, Canada, 1998.
    • (1998) CYMSTAB User Guide


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.