메뉴 건너뛰기




Volumn 43, Issue 6, 2002, Pages 419-452

3D-CT evaluation of metallic implants: Principles, techniques, and applications

Author keywords

3D imaging; CT; CT trauma; Fractures; Metal implants; Metallic implants; Musculoskeletal CT; Orthopedic

Indexed keywords

COMPUTER ASSISTED TOMOGRAPHY; DIAGNOSTIC IMAGING; FRACTURE; GUNSHOT INJURY; HUMAN; IMAGE ANALYSIS; METAL IMPLANTATION; PRIORITY JOURNAL; REVIEW; SPINE FRACTURE; TECHNIQUE; THREE DIMENSIONAL IMAGING; TOTAL HIP PROSTHESIS;

EID: 0036954882     PISSN: 10408371     EISSN: None     Source Type: Journal    
DOI: 10.1080/10408370290807678     Document Type: Review
Times cited : (8)

References (9)
  • 1
    • 0023866456 scopus 로고
    • Evaluation of CT techniques for reducing artifacts in the presence of metallic orthopedic implants
    • Mar-Apr
    • Robertson DD, Weiss PJ, Fishman EK, Magid D, Walker PS. Evaluation of CT techniques for reducing artifacts in the presence of metallic orthopedic implants. J Comput Assist Tomogr 1988 Mar-Apt;12(2):236-41.
    • (1988) J Comput Assist Tomogr , vol.12 , Issue.2 , pp. 236-241
    • Robertson, D.D.1    Weiss, P.J.2    Fishman, E.K.3    Magid, D.4    Walker, P.S.5
  • 2
    • 0030983762 scopus 로고    scopus 로고
    • Total hip prosthesis metal-artifact suppression using iterative deblurring reconstruction
    • Mar-Apr
    • Robertson DD, Yuan J, Wang G, Vannier MW. Total hip prosthesis metal-artifact suppression using iterative deblurring reconstruction. J Comput Assist Tomogr 1997 Mar-Apt;21(2):293-8.
    • (1997) J Comput Assist Tomogr , vol.21 , Issue.2 , pp. 293-298
    • Robertson, D.D.1    Yuan, J.2    Wang, G.3    Vannier, M.W.4
  • 3
    • 0034351113 scopus 로고    scopus 로고
    • X-ray ct metal artifact reduction using wavelets: An application for imaging total hip prostheses
    • Dec
    • Zhao S, Robertson DD, Wang G, Whiting B, Bae KT. X-ray CT metal artifact reduction using wavelets: an application for imaging total hip prostheses. IEEE Trans Med Imaging 2000 Dec;19(12):1238-47.
    • (2000) IEEE Trans Med Imaging , vol.19 , Issue.12 , pp. 1238-1247
    • Zhao, S.1    Robertson, D.D.2    Wang, G.3    Whiting, B.4    Bae, K.T.5
  • 6
    • 0029940108 scopus 로고    scopus 로고
    • Artifacts and thresholding in X-ray CT of a cortical bone and titanium composite
    • May-Jun
    • Sutherland CJ, Gayou DE. Artifacts and thresholding in X-ray CT of a cortical bone and titanium composite. J Comput Assist Tomogr 1996 May-Jun;20(3):496-503
    • (1996) J Comput Assist Tomogr , vol.20 , Issue.3 , pp. 496-503
    • Sutherland, C.J.1    Gayou, D.E.2
  • 7
    • 0022461321 scopus 로고
    • Metallic hip implants: CT with multiplanar reconstruction
    • Fishman EK, Magid D, Robertson DD, et al: Metallic hip implants: CT with multiplanar reconstruction. Radiology 160:675-681, 1986.
    • (1986) Radiology , vol.160 , pp. 675-681
    • Fishman, E.K.1    Magid, D.2    Robertson, D.D.3
  • 8
    • 0035209702 scopus 로고    scopus 로고
    • Epidemiology of instability after total hip replacement
    • Oct
    • Sanchez-Sotelo J, Berry DJ. Epidemiology of instability after total hip replacement. Orthop Clin North Am 2001 Oct;32(4):543-52, vii.
    • (2001) Orthop Clin North Am , vol.32 , Issue.4 , pp. 543-552
    • Sanchez-Sotelo, J.1    Berry, D.J.2
  • 9
    • 0032928568 scopus 로고    scopus 로고
    • Epidemioiogy: Hip and knee
    • Apr
    • Berry DJ. Epidemioiogy: hip and knee. Orthop Clin North Am 1999 Apr;30(2): 183-90.
    • (1999) Orthop Clin North Am , vol.30 , Issue.2 , pp. 183-190
    • Berry, D.J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.