Automatic adjustment of manually measured QT intervals in digital electrocardiograms improves precision of electrocardiographic drug studies

Author keywords

[No Author keywords available]

Indexed keywords

ALGORITHMS; CORRELATION METHODS; DIGITAL SIGNAL PROCESSING; DRUG INTERACTIONS; ELECTROCARDIOGRAPHY; REGRESSION ANALYSIS; TOXICITY;

EID: 0036950582     PISSN: 02766574     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (8)

References (13)
  • 1
    • 0007169040 scopus 로고
    • The measurement of the Q-T interval in acute heart disease
    • Taran L, Szilagyi N. The measurement of the Q-T interval in acute heart disease. Bull St. Francis Sanatorium 1951;8-13.
    • (1951) Bull St. Francis Sanatorium , pp. 8-13
    • Taran, L.1    Szilagyi, N.2
  • 3
    • 0034669268 scopus 로고    scopus 로고
    • Measurement, interpretation and clinical potential of QT dispersion
    • Malik M, Batchvarov VN. Measurement, Interpretation and Clinical Potential of QT dispersion. J Am Coll Cardiol. 2000; 36: 1749-66.
    • (2000) J Am Coll Cardiol. , vol.36 , pp. 1749-1766
    • Malik, M.1    Batchvarov, V.N.2
  • 4
    • 0029823871 scopus 로고    scopus 로고
    • Accuracy of four automatic QT measurement techniques in cardiac patients and healthy subjects
    • McLaughlin NB, Campbell RWF, Murray A. Accuracy of four automatic QT measurement techniques in cardiac patients and healthy subjects. Heart 1996;76:422-426.
    • (1996) Heart , vol.76 , pp. 422-426
    • McLaughlin, N.B.1    Campbell, R.W.F.2    Murray, A.3
  • 5
    • 0030745373 scopus 로고    scopus 로고
    • Measuring QT dispersion: Man versus machine
    • Murray A, McLaughlin NB, Campbell RWF. Measuring QT dispersion: man versus machine. Heart 1997;77:539-542.
    • (1997) Heart , vol.77 , pp. 539-542
    • Murray, A.1    McLaughlin, N.B.2    Campbell, R.W.F.3
  • 6
    • 0032519806 scopus 로고    scopus 로고
    • Agreement and reproducibility of automatic versus manual measurement of QT interval and QT dispersion
    • Savelieva I, Yi G, Guo X, Hnatkova K, Malik M. Agreement and reproducibility of automatic versus manual measurement of QT interval and QT dispersion. Am J Cardiol 1998;81:471-477.
    • (1998) Am J Cardiol , vol.81 , pp. 471-477
    • Savelieva, I.1    Yi, G.2    Guo, X.3    Hnatkova, K.4    Malik, M.5
  • 7
    • 76949130639 scopus 로고
    • The measurement of the Q-T interval in electrocardiogram
    • Lepeschkin E, Surawicz B. The measurement of the Q-T interval in electrocardiogram. Circulation 1952;VI:378-388.
    • (1952) Circulation , vol.6 , pp. 378-388
    • Lepeschkin, E.1    Surawicz, B.2
  • 8
    • 0035135156 scopus 로고    scopus 로고
    • Morphological algebraic models of the TU-wave patterns/in idiopathic long QT syndrome
    • Padrini R, Butrous G, Statters D, Camm AJ, Malik M. Morphological algebraic models of the TU-wave patterns/in idiopathic long QT syndrome. Int J Cardiol 2001;77:151-62.
    • (2001) Int J Cardiol , vol.77 , pp. 151-162
    • Padrini, R.1    Butrous, G.2    Statters, D.3    Camm, A.J.4    Malik, M.5
  • 9
    • 0032831711 scopus 로고    scopus 로고
    • Spatial, temporal and wavefront direction characteristics of 12-lead T-wave morphology
    • Acar B, Yi G, Hnatkova K, Malik M. Spatial, temporal and wavefront direction characteristics of 12-lead T-wave morphology. Med Biol Eng Comput 1999;37(5):574-84.
    • (1999) Med Biol Eng Comput , vol.37 , Issue.5 , pp. 574-584
    • Acar, B.1    Yi, G.2    Hnatkova, K.3    Malik, M.4
  • 11
    • 0033779250 scopus 로고    scopus 로고
    • Drug-induced proarrhythmic effect: Assessment of changes in QT interval
    • Sheridan DJ. Drug-induced proarrhythmic effect: assessment of changes in QT interval. Br J Clin Pharmacol 2000;50:297-302.
    • (2000) Br J Clin Pharmacol , vol.50 , pp. 297-302
    • Sheridan, D.J.1
  • 12
    • 0034524910 scopus 로고    scopus 로고
    • The assessment of potential for QT interval prolongation with new pharmaceuticals: Impact on drug development
    • Gralinski MR. The assessment of potential for QT interval prolongation with new pharmaceuticals: impact on drug development. J Pharmacol Toxicol Methods 2000;43(2):91-9.
    • (2000) J Pharmacol Toxicol Methods , vol.43 , Issue.2 , pp. 91-99
    • Gralinski, M.R.1
  • 13
    • 0035021986 scopus 로고    scopus 로고
    • Evaluation of drug-induced QT interval prolongation: Implications for drug approval and labelling
    • Malik M, Camm AJ. Evaluation of drug-induced QT interval prolongation: implications for drug approval and labelling. Drug Saf 2001;24(5):323-51.
    • (2001) Drug Saf , vol.24 , Issue.5 , pp. 323-351
    • Malik, M.1    Camm, A.J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.