-
1
-
-
0014136512
-
Mammary artery-coronary artery anastomosis as method of treatment for angina pectoris
-
Kolessov VI: Mammary artery-coronary artery anastomosis as method of treatment for angina pectoris. J Thorac Cardiovasc Surg 54:535-544, 1967
-
(1967)
J Thorac Cardiovasc Surg
, vol.54
, pp. 535-544
-
-
Kolessov, V.I.1
-
2
-
-
0016419714
-
To use or not to use the pump oxygenator in coronary bypass operations
-
Ankeney J: To use or not to use the pump oxygenator in coronary bypass operations. Ann Thorac Surg 19:108-109, 1975
-
(1975)
Ann Thorac Surg
, vol.19
, pp. 108-109
-
-
Ankeney, J.1
-
3
-
-
0026619738
-
Coronary artery bypass without cardiopulmonary bypass
-
Pfister AJ, Zaki MS, Garcia JM, et al: Coronary artery bypass without cardiopulmonary bypass. Ann Thorac Surg 54:1085-1092, 1992
-
(1992)
Ann Thorac Surg
, vol.54
, pp. 1085-1092
-
-
Pfister, A.J.1
Zaki, M.S.2
Garcia, J.M.3
-
4
-
-
0026352084
-
Direct myocardial revascularization without extracorporeal circulation: Experience in 700 patients
-
Benetti FJ, Naselli C, Wood M, et al: Direct myocardial revascularization without extracorporeal circulation: Experience in 700 patients. Chest 100:312-316, 1991
-
(1991)
Chest
, vol.100
, pp. 312-316
-
-
Benetti, F.J.1
Naselli, C.2
Wood, M.3
-
5
-
-
0030818330
-
Inflammatory response to cardiopulmonary bypass: Mechanism involved and possible therapeutic strategies
-
Wan S, LeClere JL, Vincent JL: Inflammatory response to cardiopulmonary bypass: Mechanism involved and possible therapeutic strategies. Chest 112:676-692, 1997
-
(1997)
Chest
, vol.112
, pp. 676-692
-
-
Wan, S.1
LeClere, J.L.2
Vincent, J.L.3
-
6
-
-
0030012509
-
Systemic inflammatory response syndrome after cardiac operations
-
Cremer J, Martin M, Redl H, et al: Systemic inflammatory response syndrome after cardiac operations. Ann Thorac Surg 61:1714-1720, 1996
-
(1996)
Ann Thorac Surg
, vol.61
, pp. 1714-1720
-
-
Cremer, J.1
Martin, M.2
Redl, H.3
-
7
-
-
0029029770
-
A randomized study of the influence of perfusion technique and pH management strategy in 1316 patients undergoing coronary artery bypass surgery: Part II. Neurological and cognitive outcomes
-
Murkin JM, Martzke JS, Buchan AM, et al: A randomized study of the influence of perfusion technique and pH management strategy in 1316 patients undergoing coronary artery bypass surgery: Part II. Neurological and cognitive outcomes. J Thorac Cardiovasc Surg 110: 349-362, 1995
-
(1995)
J Thorac Cardiovasc Surg
, vol.110
, pp. 349-362
-
-
Murkin, J.M.1
Martzke, J.S.2
Buchan, A.M.3
-
8
-
-
0032915274
-
Embracing the heart: Perioperative management of patients undergoing off-pump coronary artery bypass grafting using the Octopus tissue stabilizer
-
Nierich AP, Diephuis J, Jansen EWL, et al: Embracing the heart: Perioperative management of patients undergoing off-pump coronary artery bypass grafting using the Octopus tissue stabilizer. J Cardiothorac Vasc Anesth 13:123-129, 1999
-
(1999)
J Cardiothorac Vasc Anesth
, vol.13
, pp. 123-129
-
-
Nierich, A.P.1
Diephuis, J.2
Jansen, E.W.L.3
-
9
-
-
0343765796
-
Experimental off-pump grafting of a circumflex branch via sternotomy using a suction device
-
Jansen EWL, Grundeman PF, Mansvelt BH, et al: Experimental off-pump grafting of a circumflex branch via sternotomy using a suction device. Ann Thorac Surg 63:S93-S96, 1997
-
(1997)
Ann Thorac Surg
, vol.63
-
-
Jansen, E.W.L.1
Grundeman, P.F.2
Mansvelt, B.H.3
-
10
-
-
0030745650
-
Minimally invasive coronary artery bypass grafting on a beating heart
-
Calafiore AM, Teodori G, Di Giammarco G, et al: Minimally invasive coronary artery bypass grafting on a beating heart. Ann Thorac Surg 63:S72-S75, 1997
-
(1997)
Ann Thorac Surg
, vol.63
-
-
Calafiore, A.M.1
Teodori, G.2
Di Giammarco, G.3
-
12
-
-
0032952742
-
Multiple arterial conduits without cardiopulmonary bypass: Early angiographic results
-
Calafiore AM, Teodori G, Di Giammarco G, et al: Multiple arterial conduits without cardiopulmonary bypass: Early angiographic results. Ann Thorac Surg 67:450-456, 1999
-
(1999)
Ann Thorac Surg
, vol.67
, pp. 450-456
-
-
Calafiore, A.M.1
Teodori, G.2
Di Giammarco, G.3
-
13
-
-
0033000597
-
Technical aspects of total revascularization in off-pump coronary bypass via sternotomy approach
-
Baumgartner FJ, Gheissari A, Capouya ER, et al: Technical aspects of total revascularization in off-pump coronary bypass via sternotomy approach. Ann Thorac Surg 67:1653-1658, 1999
-
(1999)
Ann Thorac Surg
, vol.67
, pp. 1653-1658
-
-
Baumgartner, F.J.1
Gheissari, A.2
Capouya, E.R.3
-
14
-
-
0033840589
-
Heart displacement during off-pump CABG: How well is it tolerated?
-
Nierich AP, Diephuis J, Jansen EWL, et al: Heart displacement during off-pump CABG: How well is it tolerated? Ann Thorac Surg 70:466-472, 2000
-
(2000)
Ann Thorac Surg
, vol.70
, pp. 466-472
-
-
Nierich, A.P.1
Diephuis, J.2
Jansen, E.W.L.3
-
15
-
-
0032722589
-
The enabler right ventricular circulatory support system for beating heart coronary artery bypass graft surgery
-
Geskes GG, Dekker AL, Vander Veen FH, et al: The enabler right ventricular circulatory support system for beating heart coronary artery bypass graft surgery. Ann Thorac Surg 68:1558-1561, 1999
-
(1999)
Ann Thorac Surg
, vol.68
, pp. 1558-1561
-
-
Geskes, G.G.1
Dekker, A.L.2
Vander Veen, F.H.3
-
16
-
-
0033766718
-
Off-pump versus on-pump coronary bypass in high-risk subgroups
-
Yokoyama T, Baumgartner FJ, Gheissari A, et al: Off-pump versus on-pump coronary bypass in high-risk subgroups. Ann Thorac Surg 70:1546-1550, 2000
-
(2000)
Ann Thorac Surg
, vol.70
, pp. 1546-1550
-
-
Yokoyama, T.1
Baumgartner, F.J.2
Gheissari, A.3
-
17
-
-
0033797779
-
Is low ejection fraction safe for off-pump coronary bypass operation?
-
Atom KV, Flavin TF, Emery RW, et al: Is low ejection fraction safe for off-pump coronary bypass operation? Ann Thorac Surg 70: 1021-1025, 2000
-
(2000)
Ann Thorac Surg
, vol.70
, pp. 1021-1025
-
-
Atom, K.V.1
Flavin, T.F.2
Emery, R.W.3
-
18
-
-
0033803251
-
A review of 1,582 consecutive Octopus off-pump coronary bypass patients
-
Hart JC, Spooner TH, Pym J, et al: A review of 1,582 consecutive Octopus off-pump coronary bypass patients. Ann Thorac Surg 70:1017-1020, 2000
-
(2000)
Ann Thorac Surg
, vol.70
, pp. 1017-1020
-
-
Hart, J.C.1
Spooner, T.H.2
Pym, J.3
-
19
-
-
0033967757
-
Systematic off-pump coronary artery revascularization in mutivessel disease: Experience of three hundred cases
-
Cartier R, Brann S, Dagenais F, et al: Systematic off-pump coronary artery revascularization in mutivessel disease: Experience of three hundred cases. J Thorac Cardiovasc Surg 119:221-229, 2000
-
(2000)
J Thorac Cardiovasc Surg
, vol.119
, pp. 221-229
-
-
Cartier, R.1
Brann, S.2
Dagenais, F.3
-
21
-
-
0033596759
-
Inertia of success: A response to minimally invasive coronary bypass: A dissenting opinion
-
editorial
-
Mack M, Damiano R, Matheny R, et al: Inertia of success: A response to minimally invasive coronary bypass: A dissenting opinion. Circulation 99:1404-1406, 1999 (editorial)
-
(1999)
Circulation
, vol.99
, pp. 1404-1406
-
-
Mack, M.1
Damiano, R.2
Matheny, R.3
-
22
-
-
18844470039
-
Hemodynamic changes during displacement of the beating heart by the Utrecht Octopus method
-
Grundeman PF, Borst C, Van Herwaarden JA, et al: Hemodynamic changes during displacement of the beating heart by the Utrecht Octopus method. Ann Thorac Surg 63:S88-S92, 1997
-
(1997)
Ann Thorac Surg
, vol.63
-
-
Grundeman, P.F.1
Borst, C.2
Van Herwaarden, J.A.3
-
23
-
-
0032076551
-
Vertical displacement of the beating heart by the Octopus tissue stabilizer: Influence on coronary flow
-
Grundeman PF, Borst C, Van Herwaarden JA, et al: Vertical displacement of the beating heart by the Octopus tissue stabilizer: Influence on coronary flow. Ann Thorac Surg 65:1348-1352, 1998
-
(1998)
Ann Thorac Surg
, vol.65
, pp. 1348-1352
-
-
Grundeman, P.F.1
Borst, C.2
Van Herwaarden, J.A.3
-
24
-
-
0012495920
-
Anesthesia for off-pump coronary artery bypass surgery
-
Stillman P, Soloniuk L: Anesthesia for off-pump coronary artery bypass surgery. The Internet Journal of Anesthesiology 4:2 (http:// www.icaap.org/iuicode?81.4.2.6), 2000
-
(2000)
The Internet Journal of Anesthesiology
, vol.4
, pp. 2
-
-
Stillman, P.1
Soloniuk, L.2
-
25
-
-
0034008745
-
Hemodynamic monitoring in patients undergoing off-pump coronary artery bypass graft surgery using the Octopus tissue stabilizer: Left atrial pressure as a gold standard
-
Grubitzsch H, Ansorge K, Wollert HG, et al: Hemodynamic monitoring in patients undergoing off-pump coronary artery bypass graft surgery using the Octopus tissue stabilizer: Left atrial pressure as a gold standard. J Cardiothorac Vasc Anesth 14:105-110, 2000
-
(2000)
J Cardiothorac Vasc Anesth
, vol.14
, pp. 105-110
-
-
Grubitzsch, H.1
Ansorge, K.2
Wollert, H.G.3
|