메뉴 건너뛰기




Volumn 42, Issue 9, 2002, Pages 691-696

Radiaton dose and dose reduction in multidetector row CT (MDCT);Strahlendosis und möglichkeiten zur dosisreduktion in der mehrschicht-CT

Author keywords

Computed tomography; CTDI; Dose reduction; Radiation exposure

Indexed keywords

ARTICLE; COLLIMATOR; COMPUTER ASSISTED TOMOGRAPHY; DIAGNOSTIC IMAGING; ELECTROCARDIOGRAM; HUMAN; MULTIDETECTOR COMPUTED TOMOGRAPHY; PATIENT POSITIONING; RADIATION DOSE; RADIATION EXPOSURE; RADIATION PROTECTION;

EID: 0036939254     PISSN: 0033832X     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00117-002-0799-x     Document Type: Article
Times cited : (13)

References (9)
  • 2
    • 0034257872 scopus 로고    scopus 로고
    • Direct comparison of a xenon and a solid-state CT detector system: Measurements under working conditions
    • Fuchs T, Kachelriess M, Kalender WA (2000) Direct comparison of a xenon and a solid-state CT detector system: measurements under working conditions. IEEE Trans Med Imaging 19:941-948
    • (2000) IEEE Trans Med Imaging , vol.19 , pp. 941-948
    • Fuchs, T.1    Kachelriess, M.2    Kalender, W.A.3
  • 3
    • 18044404843 scopus 로고    scopus 로고
    • CT-expositionspraxis in der bundesrepublik Deutschland: Ergebnisse einer bundesweiten umfrage im jahre 1999
    • Galanski M, Nagel HD, Stamm G (2001) CT-Expositionspraxis in der Bundesrepublik Deutschland: Ergebnisse einer bundesweiten Umfrage im Jahre 1999. Fortschr Röntgenstr 173:R1-R66
    • (2001) Fortschr Röntgenstr , vol.173 , pp. R1-R66
    • Galanski, M.1    Nagel, H.D.2    Stamm, G.3
  • 4
    • 0035012334 scopus 로고    scopus 로고
    • Dose reduction in spiral-CT: Detection of pulmonary coin lesions with and without anatomically adjusted modulation of tube current
    • Greess H, Baum U, Wolf H, Lell M, Nomayr A, Schmidt B, Kalender WA, Bautz W (2001) Dose reduction in spiral-CT: detection of pulmonary coin lesions with and without anatomically adjusted modulation of tube current. Fortschr Röntgenstr 173:466-470
    • (2001) Fortschr Röntgenstr , vol.173 , pp. 466-470
    • Greess, H.1    Baum, U.2    Wolf, H.3    Lell, M.4    Nomayr, A.5    Schmidt, B.6    Kalender, W.A.7    Bautz, W.8
  • 5
    • 0034055634 scopus 로고    scopus 로고
    • Dose reduction in computed tomography by attenuation-based on-line modulation of tube current: Evaluation of six anatomical regions
    • Greess H, Baum U, Wolf H, Lell M, Nomayr A, Schmidt B, Kalender WA, Bautz W (2000) Dose reduction in computed tomography by attenuation-based on-line modulation of tube current: evaluation of six anatomical regions. Eur Radiol 10:391-394
    • (2000) Eur Radiol , vol.10 , pp. 391-394
    • Greess, H.1    Baum, U.2    Wolf, H.3    Lell, M.4    Nomayr, A.5    Schmidt, B.6    Kalender, W.A.7    Bautz, W.8
  • 6
    • 0043033136 scopus 로고    scopus 로고
    • Dose reduction in CT examination of children by an attenuation-based on-line modulation of tube current (CARE Dose)
    • Greess H, Nomayr A, Wolf H, Baum U, Lell M, Bowing B, Kalender W, Bautz WA (2002) Dose reduction in CT examination of children by an attenuation-based on-line modulation of tube current (CARE Dose). Eur Radiol 12:1571-1576
    • (2002) Eur Radiol , vol.12 , pp. 1571-1576
    • Greess, H.1    Nomayr, A.2    Wolf, H.3    Baum, U.4    Lell, M.5    Bowing, B.6    Kalender, W.7    Bautz, W.A.8
  • 7
    • 0033735138 scopus 로고    scopus 로고
    • Technique factors and image quality as functions of patient weight at abdominal CT
    • Huda W, Scalzetti EM, Levin G (2000) Technique factors and image quality as functions of patient weight at abdominal CT. Radiology 217:430-435
    • (2000) Radiology , vol.217 , pp. 430-435
    • Huda, W.1    Scalzetti, E.M.2    Levin, G.3
  • 8
    • 0036580665 scopus 로고    scopus 로고
    • Multislice helical CT of the heart with retrospective ECG gating: Reduction of radiation exposure by ECG-controlled tube current modulalation
    • Jakobs TF, Becker CR, Ohnesorge B, Flohr T, Suess C, Schoepf UJ, Reiser MF (2002) Multislice helical CT of the heart with retrospective ECG gating: reduction of radiation exposure by ECG-controlled tube current modulalation. Eur Radiol 12:1081-1086
    • (2002) Eur Radiol , vol.12 , pp. 1081-1086
    • Jakobs, T.F.1    Becker, C.R.2    Ohnesorge, B.3    Flohr, T.4    Suess, C.5    Schoepf, U.J.6    Reiser, M.F.7
  • 9
    • 0036583268 scopus 로고    scopus 로고
    • Überblick über strahlendosis und bildqualität in der computertomographie
    • Prokop M (2002) Überblick über Strahlendosis und Bildqualität in der Computertomographie. Fortschr Röntgenstr 174:631-636
    • (2002) Fortschr Röntgenstr , vol.174 , pp. 631-636
    • Prokop, M.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.