메뉴 건너뛰기




Volumn 240, Issue 5, 2002, Pages 415-419

Long-term results of penetrating keratoplasty using a single or double running suture technique

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ARTICLE; ASTIGMATISM; COMPUTER ANALYSIS; CONGENITAL CORNEA DYSTROPHY; CONTROLLED STUDY; CORNEA CURVATURE; EYE REFRACTION; FEMALE; FOLLOW UP; HUMAN; KERATOCONUS; MAJOR CLINICAL STUDY; MALE; PENETRATING KERATOPLASTY; POSTOPERATIVE COMPLICATION; POSTOPERATIVE PERIOD; PRIORITY JOURNAL; PROSPECTIVE STUDY; STATISTICAL SIGNIFICANCE; SURGICAL TECHNIQUE; SUTURE REMOVAL; SUTURING METHOD; TREATMENT OUTCOME; VISION;

EID: 0036934690     PISSN: 0721832X     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00417-002-0444-4     Document Type: Article
Times cited : (19)

References (28)
  • 1
    • 0023934053 scopus 로고
    • The effect of suture removal on post keratoplasty astigmatism
    • Binder PS (1988) The effect of suture removal on post keratoplasty astigmatism. Am J Ophthalmol 105:637-45
    • (1988) Am. J. Ophthalmol. , vol.105 , pp. 637-645
    • Binder, P.S.1
  • 2
    • 0012444220 scopus 로고
    • Changes in astigmatism after removal of individual sutures in penetrating keratoplasty
    • ARVO Abstracts
    • Burk LL, Redjaee B, Stulting RD, Waring GO III (1986) Changes in astigmatism after removal of individual sutures in penetrating keratoplasty. ARVO Abstracts. Invest Ophthalmol Vis Sci 27 [Suppl 92]
    • (1986) Invest. Ophthalmol. Vis. Sci. , vol.27 , Issue.SUPPL. 92
    • Burk, L.L.1    Redjaee, B.2    Stulting, R.D.3    Waring G.O. III4
  • 3
    • 0031657579 scopus 로고    scopus 로고
    • Different suturing techniques variously affect the regularity of postkeratoplasty astigmatism
    • Busin M, Monks T, Al-Nawaiseh I (1998) Different suturing techniques variously affect the regularity of postkeratoplasty astigmatism. Ophthalmology 105:1200-1205
    • (1998) Ophthalmology , vol.105 , pp. 1200-1205
    • Busin, M.1    Monks, T.2    Al-Nawaiseh, I.3
  • 7
    • 0019426985 scopus 로고
    • Results, of penetrating keratoplasty using a double running suture technique
    • Davison JA, Bourne WM (1981) Results, of penetrating keratoplasty using a double running suture technique. Arch Ophthalmol 99:1591-1595
    • (1981) Arch. Ophthalmol. , vol.99 , pp. 1591-1595
    • Davison, J.A.1    Bourne, W.M.2
  • 8
    • 0028834184 scopus 로고
    • A new cornea-marking device for penetrating keratoplasty and refractive corneal procedures
    • Dunker GIW, Noelle DB (1995) A new cornea-marking device for penetrating keratoplasty and refractive corneal procedures. Ophthalmologica 209:25-26
    • (1995) Ophthalmologica , vol.209 , pp. 25-26
    • Dunker, G.I.W.1    Noelle, D.B.2
  • 9
    • 0017019026 scopus 로고
    • Suture technique for penetrating keratoplasty
    • Hoffmann F (1976) Suture technique for penetrating keratoplasty Klin Monatsbl Augenheilkd 169(5):584-590
    • (1976) Klin Monatsbl Augenheilkd , vol.169 , Issue.5 , pp. 584-590
    • Hoffmann, F.1
  • 11
    • 0031751585 scopus 로고    scopus 로고
    • Depth of lamellar keratoplasty with the guided trephine system for transplantation of full-thickness donor section
    • Krumeich JH, Daniel J, Winter M (1998) Depth of lamellar keratoplasty with the guided trephine system for transplantation of full-thickness donor section. Ophthalmologe 95(11):748-754
    • (1998) Ophthalmologe , vol.95 , Issue.11 , pp. 748-754
    • Krumeich, J.H.1    Daniel, J.2    Winter, M.3
  • 12
    • 0027446446 scopus 로고
    • Changes in keratometric astigmatism after suture removal more than one year after penetrating keratoplasty
    • Mader TH, Yuan R, Lynn MJ, Stulting RD, Wilson LA, Waring GO III (1993) Changes in keratometric astigmatism after suture removal more than one year after penetrating keratoplasty. Ophthalmology 100:119-127
    • (1993) Ophthalmology , vol.100 , pp. 119-127
    • Mader, T.H.1    Yuan, R.2    Lynn, M.J.3    Stulting, R.D.4    Wilson, L.A.5    Waring G.O. III6
  • 13
    • 0032947355 scopus 로고    scopus 로고
    • Long term results of single continuous suture adjustment to reduce penetrating keratoplasty astigmatism
    • McNeill, Aaen VJ (1999) Long term results of single continuous suture adjustment to reduce penetrating keratoplasty astigmatism. Cornea 18:19-24
    • (1999) Cornea , vol.18 , pp. 19-24
    • McNeill, A.1    Aaen, V.J.2
  • 14
    • 0023908007 scopus 로고
    • The effect of removing running sutures on astigmatism after penetrating keratoplasty
    • Musch DC, Mayer RF, Sugar A (1988) The effect of removing running sutures on astigmatism after penetrating keratoplasty. Arch Ophthalmol 106:488-492
    • (1988) Arch. Ophthalmol. , vol.106 , pp. 488-492
    • Musch, D.C.1    Mayer, R.F.2    Sugar, A.3
  • 15
    • 0019522993 scopus 로고
    • The effect of scleral fixation ring placement and trephine tilting on keratoplasty wound size and donor shape
    • Olson RJ (1981) The effect of scleral fixation ring placement and trephine tilting on keratoplasty wound size and donor shape. Ophthalmic Surg 12:23-26
    • (1981) Ophthalmic Surg. , vol.12 , pp. 23-26
    • Olson, R.J.1
  • 17
    • 0033808078 scopus 로고    scopus 로고
    • Corneal dimensions in various types of corneal dystrophies and their effect on penetrating keratoplasty
    • Seitz B, Langenbucher A, Zagrada D, Budde W, Kus MM (2000) Corneal dimensions in various types of corneal dystrophies and their effect on penetrating keratoplasty. Klin Monatsbl Augenheilkd 217(3):152-158
    • (2000) Klin Monatsbl Augenheilkd , vol.217 , Issue.3 , pp. 152-158
    • Seitz, B.1    Langenbucher, A.2    Zagrada, D.3    Budde, W.4    Kus, M.M.5
  • 18
    • 0035150284 scopus 로고    scopus 로고
    • Graft endothelium and thickness after penetrating keratoplasty, comparing mechanical and excimer laser trephination: A prospective randomised study
    • Seitz B, Langenbucher A, Nguyen NX, Kus MM, Kuchle M, Naumann GO (2001) Graft endothelium and thickness after penetrating keratoplasty, comparing mechanical and excimer laser trephination: a prospective randomised study. Graefe's Arch Clin Exp Ophthalmol 239(1):12-17
    • (2001) Graefe's Arch. Clin. Exp. Ophthalmol. , vol.239 , Issue.1 , pp. 12-17
    • Seitz, B.1    Langenbucher, A.2    Nguyen, N.X.3    Kus, M.M.4    Kuchle, M.5    Naumann, G.O.6
  • 19
    • 0028232534 scopus 로고
    • Randomizes clinical trial comparing astigmatism and visual rehabilitation after penetrating keratoplasty with and without intraoperative suture adjustment
    • Serdarevic ON, Gilles JR, Pouliquen Y (1994) Randomizes clinical trial comparing astigmatism and visual rehabilitation after penetrating keratoplasty with and without intraoperative suture adjustment. Ophthalmology 101:990-999
    • (1994) Ophthalmology , vol.101 , pp. 990-999
    • Serdarevic, O.N.1    Gilles, J.R.2    Pouliquen, Y.3
  • 20
    • 0031787588 scopus 로고    scopus 로고
    • Intraoperative versus postoperative suture adjustment after penetrating keratoplasty
    • Shimazaki J, Shimmura S, Tsubota K (1998) Intraoperative versus postoperative suture adjustment after penetrating keratoplasty. Cornea 17:590-594
    • (1998) Cornea , vol.17 , pp. 590-594
    • Shimazaki, J.1    Shimmura, S.2    Tsubota, K.3
  • 21
    • 0029977784 scopus 로고    scopus 로고
    • Penetrating keratoplasty with donor and recipient corneas of the same diameter
    • Spadea L, Bianco G, Mastrofini MC, Balestrazzi E (1996) Penetrating keratoplasty with donor and recipient corneas of the same diameter. Ophthalmic Surg 27:425-430
    • (1996) Ophthalmic Surg. , vol.27 , pp. 425-430
    • Spadea, L.1    Bianco, G.2    Mastrofini, M.C.3    Balestrazzi, E.4
  • 22
    • 0029398579 scopus 로고
    • Advantages of double continuous cross-stitch suture compared with simple continuous suture in penetrating keratoplasty
    • Sundmacher R (1995) Advantages of double continuous cross-stitch suture compared with simple continuous suture in penetrating keratoplasty. Klin Monatsbl Augenheilkd 207:342-343
    • (1995) Klin. Monatsbl. Augenheilkd , vol.207 , pp. 342-343
    • Sundmacher, R.1
  • 24
    • 0018776295 scopus 로고
    • Astigmatism considerations in corneal graft
    • Troutman RC (1979) Astigmatism considerations in corneal graft. Ophthalmic Surg 10(5):21-26
    • (1979) Ophthalmic Surg. , vol.10 , Issue.5 , pp. 21-26
    • Troutman, R.C.1
  • 26
    • 0024455328 scopus 로고
    • The Hanna suction punch block and trephine system for penetrating keratoplasty
    • Waring GO III, Hanna KD (1989) The Hanna suction punch block and trephine system for penetrating keratoplasty. Arch Ophthalmol 107:1536-1539
    • (1989) Arch. Ophthalmol. , vol.107 , pp. 1536-1539
    • Waring G.O. III1    Hanna, K.D.2
  • 27
    • 0024502209 scopus 로고
    • Effect of recipient-donor trephine size disparity on refractive error in keratoconus
    • Wilson SE, Bourne WM (1989) Effect of recipient-donor trephine size disparity on refractive error in keratoconus. Ophthalmology 96:299-305
    • (1989) Ophthalmology , vol.96 , pp. 299-305
    • Wilson, S.E.1    Bourne, W.M.2
  • 28
    • 0022400810 scopus 로고
    • Results of a double suture in penetrating keratoplasty performed in keratoconus patients
    • Young SRS, Olson RJ (1985) Results of a double suture in penetrating keratoplasty performed in keratoconus patients. Ophthalmic Surg 16:779-786
    • (1985) Ophthalmic Surg. , vol.16 , pp. 779-786
    • Young, S.R.S.1    Olson, R.J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.