메뉴 건너뛰기




Volumn 506 B, Issue , 2002, Pages 1097-1105

Reliability of measurements of tear physiology

Author keywords

[No Author keywords available]

Indexed keywords

ADOLESCENT; ADULT; CLINICAL ARTICLE; CONFERENCE PAPER; DEVICE; DIAGNOSTIC TEST; EYE IRRITATION; FEMALE; HUMAN; LACRIMAL FLUID; MALE; PRIORITY JOURNAL; RELIABILITY; STATISTICAL ANALYSIS; TEAR FILM; TEAR FLOW;

EID: 0036921942     PISSN: 00652598     EISSN: None     Source Type: Book Series    
DOI: 10.1007/978-1-4615-0717-8_154     Document Type: Conference Paper
Times cited : (2)

References (29)
  • 1
    • 0001923330 scopus 로고
    • Repeatability and variability of Schirmer Test
    • S. Patel, J. Farrell, H. Bevan, Repeatability and variability of Schirmer Test, Optician. 194(5122):12 (1987).
    • (1987) Optician , vol.194 , Issue.5122 , pp. 12
    • Patel, S.1    Farrell, J.2    Bevan, H.3
  • 2
    • 0027243496 scopus 로고
    • Schirmer Test II: A clinical study of its repeatability
    • P. Cho, M. Yap, Schirmer Test II: A clinical study of its repeatability, Optom. Vis. Sc. 70:157 (1993).
    • (1993) Optom. Vis. Sc. , vol.70 , pp. 157
    • Cho, P.1    Yap, M.2
  • 3
    • 0018307704 scopus 로고
    • Schirmer test and breakup time of the tear film in normal subjects
    • A. Shapero, S. Merin, Schirmer test and breakup time of the tear film in normal subjects, Am J. Ophthalmol. 88:752 (1979).
    • (1979) Am J. Ophthalmol. , vol.88 , pp. 752
    • Shapero, A.1    Merin, S.2
  • 4
    • 0001916030 scopus 로고
    • Repeatability of the phenol-red thread and tear thinning time tests for tear film function
    • S.A. Little, A.S. Bruce, Repeatability of the phenol-red thread and tear thinning time tests for tear film function, Clin. Exper. Optom. 77:64 (1994).
    • (1994) Clin. Exper. Optom. , vol.77 , pp. 64
    • Little, S.A.1    Bruce, A.S.2
  • 5
    • 0027508529 scopus 로고
    • The cotton thread test: Brief review and a clinical study of its reliability on Hong Kong/Chinese
    • P. Cho, The cotton thread test: brief review and a clinical study of its reliability on Hong Kong/Chinese, Optom. Vis. Sci. 70:804 (1993).
    • (1993) Optom. Vis. Sci. , vol.70 , pp. 804
    • Cho, P.1
  • 6
    • 0026678585 scopus 로고
    • Reliability of the tear breakup time technique of assessing tear stability and the locations of tear breakup in Hong Kong/Chinese
    • P. Cho, B. Brown, I. Chan, R. Conway, M. Yap, Reliability of the tear breakup time technique of assessing tear stability and the locations of tear breakup in Hong Kong/Chinese, Optom. Vis. Sci. 69:879 (1992).
    • (1992) Optom. Vis. Sci. , vol.69 , pp. 879
    • Cho, P.1    Brown, B.2    Chan, I.3    Conway, R.4    Yap, M.5
  • 7
    • 0015578699 scopus 로고
    • Factors affecting tear film breakup in normal eyes
    • M.A. Lemp, J.R. Hamill, Factors affecting tear film breakup in normal eyes, Arch. Ophthalmol. 89:103 (1973).
    • (1973) Arch. Ophthalmol. , vol.89 , pp. 103
    • Lemp, M.A.1    Hamill, J.R.2
  • 8
    • 0012282241 scopus 로고    scopus 로고
    • Evaluating the functional impact of dry eye: The Ocular Surface Disease Index
    • J.G. Walt, M.M. Rowe, K.L.Stern, Evaluating the functional impact of dry eye: the Ocular Surface Disease Index, Drug Inf. J. 31:1436 (1997).
    • (1997) Drug Inf. J. , vol.31 , pp. 1436
    • Walt, J.G.1    Rowe, M.M.2    Stern, K.L.3
  • 10
    • 0024402121 scopus 로고
    • Human tear film (pre-rupture phase time) (TP-RPT) a non-evasive technique for evaluating the pro-corneal tear film using a Noval keratometer mire
    • N. Hirji, S. Patel, M. Callendar, Human tear film (pre-rupture phase time) (TP-RPT) a non-evasive technique for evaluating the pro-corneal tear film using a Noval keratometer mire, Ophthal. Physiol. Opt. 9:139 (1989).
    • (1989) Ophthal. Physiol. Opt. , vol.9 , pp. 139
    • Hirji, N.1    Patel, S.2    Callendar, M.3
  • 11
    • 0025647187 scopus 로고
    • Effect of artificial tear solutions and saline on tear film evaporation
    • G.R. Trees, A. Tomlinson, Effect of artificial tear solutions and saline on tear film evaporation, Optom. Vis. Sci. 67:886 (1990).
    • (1990) Optom. Vis. Sci. , vol.67 , pp. 886
    • Trees, G.R.1    Tomlinson, A.2
  • 12
    • 0031868343 scopus 로고    scopus 로고
    • Tear film interferometry as a diagnostic tool for evaluating normal and dry eye tear film
    • M.G. Doane, M.E. Lee, Tear film interferometry as a diagnostic tool for evaluating normal and dry eye tear film, Ad. Exp. Med. Biol. 438:297 (1998).
    • (1998) Ad. Exp. Med. Biol. , vol.438 , pp. 297
    • Doane, M.G.1    Lee, M.E.2
  • 13
    • 0024385755 scopus 로고
    • An instrument for invivo tear film interferometry
    • M.G. Doane, An instrument for invivo tear film interferometry, Optom. Vis. Sci. 66:383 (1989).
    • (1989) Optom. Vis. Sci. , vol.66 , pp. 383
    • Doane, M.G.1
  • 14
  • 15
    • 0345237405 scopus 로고    scopus 로고
    • Minitab Inc., 3081 Enterprise Drive, State College, PA 16801-3008, USA
    • Minitab Inc., 3081 Enterprise Drive, State College, PA 16801-3008, USA.
  • 16
    • 0345669278 scopus 로고    scopus 로고
    • SPSS Inc., 233 South Wacker Drive, Chicago, II 60606-6307, USA.
    • SPSS Inc., 233 South Wacker Drive, Chicago, II 60606-6307, USA.
  • 17
    • 48249153186 scopus 로고
    • Intraclass correlations: Uses in assessing rater reliability
    • P.E. Shrout, J.L. Fleiss, Intraclass correlations: uses in assessing rater reliability, Psychol. Bull. 86:420 (1979).
    • (1979) Psychol. Bull. , vol.86 , pp. 420
    • Shrout, P.E.1    Fleiss, J.L.2
  • 21
    • 0031055619 scopus 로고    scopus 로고
    • Importance of the lipid layer in human tear film stability and evaporation
    • J.P. Craig, A. Tomlinson, Importance of the lipid layer in human tear film stability and evaporation, Optom. Vis. Sci. 74:8 (1997).
    • (1997) Optom. Vis. Sci. , vol.74 , pp. 8
    • Craig, J.P.1    Tomlinson, A.2
  • 22
    • 0030047026 scopus 로고    scopus 로고
    • Model of ocular tear film function
    • W.D. Mathers, Model of ocular tear film function, Cornea. 15:110 (1996).
    • (1996) Cornea , vol.15 , pp. 110
    • Mathers, W.D.1
  • 23
    • 0028849933 scopus 로고
    • Report of the National Eye Research/Industry Workshop on clinical trials in dry eye
    • M.A. Lemp, Report of the National Eye Research/Industry Workshop on clinical trials in dry eye, CLAO J. 21:221 (1995).
    • (1995) CLAO J. , vol.21 , pp. 221
    • Lemp, M.A.1
  • 25
    • 0019722094 scopus 로고
    • Tear film physiology and contact lens wear II. Contact lens tear film interaction
    • F.J. Holly, Tear film physiology and contact lens wear II. Contact lens tear film interaction. Am J. Optom. Physiol. Opt. 58:331 (1981).
    • (1981) Am J. Optom. Physiol. Opt. , vol.58 , pp. 331
    • Holly, F.J.1
  • 26
    • 0021978994 scopus 로고
    • Mechanism of tear film rupture and its implications for contact lens tolerance
    • A. Sharma, E. Ruckenstein, Mechanism of tear film rupture and its implications for contact lens tolerance, Am J. Optom. Physiol. Opt. 62:246 (1985).
    • (1985) Am J. Optom. Physiol. Opt. , vol.62 , pp. 246
    • Sharma, A.1    Ruckenstein, E.2
  • 27
    • 0000439872 scopus 로고
    • Tear evaporation and the human eye: The effects of contact lens wear
    • A. Tomlinson, T.H. Cedarstaff, Tear evaporation and the human eye: the effects of contact lens wear, J. Brit. Contact Lens Assn. 5:141 (1982).
    • (1982) J. Brit. Contact Lens Assn. , vol.5 , pp. 141
    • Tomlinson, A.1    Cedarstaff, T.H.2
  • 29
    • 0025647187 scopus 로고
    • Effect of artificial tear solutions and saline on tear film evaporation
    • Optom. Vis. Sc.
    • G.R. Trees, A. Tomlinson, Optom. Vis. Sc. Effect of artificial tear solutions and saline on tear film evaporation, Optom. Vis. Sci. 67:886 (1990).
    • (1990) Optom. Vis. Sci. , vol.67 , pp. 886
    • Trees, G.R.1    Tomlinson, A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.