메뉴 건너뛰기




Volumn 3, Issue , 2002, Pages 2068-2069

Nanoscale surface modification of thin film microelectrodes to improve biocompatibility

Author keywords

Microelectrodes; Multichannel recording; Thin film technology

Indexed keywords

BIOCOMPATIBILITY; BIOELECTRIC POTENTIALS; BRAIN; CERAMIC MATERIALS; HISTOLOGY; ORGANIC ACIDS; POLYMERS; PROSTHETICS; SPIN COATING; SURFACE TREATMENT; THIN FILMS; TISSUE;

EID: 0036916746     PISSN: 05891019     EISSN: None     Source Type: Journal    
DOI: 10.1109/IEMBS.2002.1053171     Document Type: Article
Times cited : (2)

References (9)
  • 1
    • 0000212674 scopus 로고
    • On certain integrals of lipschitz-hankel type involving products of bessel functions
    • April
    • G. Eason, B. Noble, and I.N. Sneddon, “On certain integrals of Lipschitz-Hankel type involving products of Bessel functions,” Phil. Trans. Roy. Soc. London, A247, pp. 529-551, April 1955.
    • (1955) Phil. Trans. Roy. Soc. London , vol.A247 , pp. 529-551
    • Eason, G.1    Noble, B.2    Sneddon, I.N.3
  • 2
    • 0032771124 scopus 로고    scopus 로고
    • Examination of the spatial and temporal distribution of sensory cortical activity using a 100-electrode array
    • Rousche, P.J., Petersen, R.S., Battiston, S., Giannotta, S., Diamond, M.E., Examination of the spatial and temporal distribution of sensory cortical activity using a 100-electrode array, J. of Neurosci. Methods, 90, 57, 1999.
    • (1999) J. of Neurosci. Methods , vol.90 , pp. 57
    • Rousche, P.J.1    Petersen, R.S.2    Battiston, S.3    Giannotta, S.4    Diamond, M.E.5
  • 3
    • 0030848541 scopus 로고    scopus 로고
    • Neonatal whisker removal reduces the discrimination of tactile stimuli by thalamic ensembles in adult rats
    • Nicolelis, M.A., Lin, R.C., Chapin, J.K., Neonatal whisker removal reduces the discrimination of tactile stimuli by thalamic ensembles in adult rats, J Neurophys., 78, 1691, 1997.
    • (1997) J Neurophys. , vol.78 , pp. 1691
    • Nicolelis, M.A.1    Lin, R.C.2    Chapin, J.K.3
  • 4
    • 0003291039 scopus 로고    scopus 로고
    • Electrodes for many single neuron recordings
    • Nicolelis, M.A.L. Ed., CRC Press, New York
    • Schmidt, E.M., Electrodes for many single neuron recordings, in in Methods for Neural Ensemble Recordings, Nicolelis, M.A.L. Ed., CRC Press, New York, 1999.
    • (1999) Methods for Neural Ensemble Recordings
    • Schmidt, E.M.1
  • 5
    • 0003259421 scopus 로고    scopus 로고
    • Multichannel electrode design: Considerations for different applications
    • Nicolelis, M.A.L. Ed., CRC Press, New York
    • Moxon, K.A., Multichannel electrode design: Considerations for different applications, in Methods for Neural Ensemble Recordings, Nicolelis, M.A.L. Ed., CRC Press, New York, 1999.
    • (1999) Methods for Neural Ensemble Recordings
    • Moxon, K.A.1
  • 6
    • 0026882265 scopus 로고
    • Factors influencing the biocompatibility of insertable silicon microshafts in cerebral cortex
    • Edell, D.J., Toi, V.V., McNeil, V.M., Clark, L.D., Factors influencing the biocompatibility of insertable silicon microshafts in cerebral cortex, IEEE Transactions on Biomedical Engineering, 39(6), 635, 1992.
    • (1992) IEEE Transactions on Biomedical Engineering , vol.39 , Issue.6 , pp. 635
    • Edell, D.J.1    Toi, V.V.2    McNeil, V.M.3    Clark, L.D.4
  • 7
    • 0033485808 scopus 로고    scopus 로고
    • Long-term recording characteristics of wire microelectrode arrays implanted in cerebral cortex
    • Williams, C., rennaker, R.L., Kipke, D.R. Long-term recording characteristics of wire microelectrode arrays implanted in cerebral cortex, Brain research protocols, 4, 303-313, 1999.
    • (1999) Brain Research Protocols , vol.4 , pp. 303-313
    • Williams, C.1    Rennaker, R.L.2    Kipke, D.R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.