메뉴 건너뛰기




Volumn 80, Issue 6, 2002, Pages 652-655

Analysis of mean retinal transit time from fluorescein angiography in human eyes: Normal values and reproducibility

Author keywords

Arterio venous passage time; Fluorescein angiography; Impulse response analysis; Mean transit time; Reproducibility

Indexed keywords

ADULT; ARTICLE; BLOOD FLOW VELOCITY; CONTROLLED STUDY; DIGITALIZATION; FEMALE; FLUORESCENCE ANGIOGRAPHY; HUMAN; HUMAN EXPERIMENT; IMAGE DISPLAY; INTERMETHOD COMPARISON; MALE; NORMAL HUMAN; NORMAL VALUE; PRIORITY JOURNAL; RADIOLOGICAL PROCEDURES; REPRODUCIBILITY; RETINA BLOOD FLOW; SCANNING LASER OPHTHALMOSCOPE; STATISTICAL ANALYSIS;

EID: 0036915116     PISSN: 13953907     EISSN: None     Source Type: Journal    
DOI: 10.1034/j.1600-0420.2002.800617.x     Document Type: Article
Times cited : (20)

References (21)
  • 2
    • 0015767851 scopus 로고
    • Injection technique for indocyanine green and sodium fluorescein dye angiography of the eye
    • Flower RW (1979): Injection technique for indocyanine green and sodium fluorescein dye angiography of the eye. Invest Ophthalmol Vis Sci 12: 881-895.
    • (1979) Invest Ophthalmol. Vis. Sci. , vol.12 , pp. 881-895
    • Flower, R.W.1
  • 3
    • 0017608001 scopus 로고
    • Relative photometric measurements of retinal circulation (Dromofluorograms), a televison technique
    • Fonda S & Bagolini B (1977): Relative photometric measurements of retinal circulation (Dromofluorograms), a televison technique. Arch Ophthalmol 95: 302-307.
    • (1977) Arch. Ophthalmol. , vol.95 , pp. 302-307
    • Fonda, S.1    Bagolini, B.2
  • 5
    • 0001697161 scopus 로고
    • A photographic method for measuring the mean retinal circulation time using fluorescein
    • Hickam JB & Frayser R (1965): A photographic method for measuring the mean retinal circulation time using fluorescein. Invest Ophthalmol 4: 876-884.
    • (1965) Invest Ophthalmol. , vol.4 , pp. 876-884
    • Hickam, J.B.1    Frayser, R.2
  • 6
    • 0021081006 scopus 로고
    • Quantification of characteristic blood flow parameters in the vessels of the retina with a picture analysis system for video-fluorescence angiograms; initial findings
    • Jung F, Kiesewetter H, Körber N, Wolf S, Reim M & Müller G (1983): Quantification of characteristic blood flow parameters in the vessels of the retina with a picture analysis system for video-fluorescence angiograms; initial findings. Graefe's Arch Clin Exp Ophthalmol 221: 133-136.
    • (1983) Graefe's Arch. Clin. Exp. Ophthalmol. , vol.221 , pp. 133-136
    • Jung, F.1    Kiesewetter, H.2    Körber, N.3    Wolf, S.4    Reim, M.5    Müller, G.6
  • 8
    • 0003427386 scopus 로고
    • Volume/flow or mass/flux ratio (mean transit time). II. Bolus injection
    • New York: Raven Press
    • Lassen NA & Perl W (1979): Volume/flow or mass/flux ratio (mean transit time). II. Bolus injection. In: Tracer Kinetic Methods in Medical Physiology. New York: Raven Press. 76-101.
    • (1979) Tracer Kinetic Methods in Medical Physiology , pp. 76-101
    • Lassen, N.A.1    Perl, W.2
  • 9
    • 77049181625 scopus 로고
    • On the theory of the indicator-dilution method for measurement of blood flow and volume
    • Meier P & Zierler KL (1954): On the theory of the indicator-dilution method for measurement of blood flow and volume. J AppI Physiol: 6: 731-744.
    • (1954) J. Appl. Physiol. , vol.6 , pp. 731-744
    • Meier, P.1    Zierler, K.L.2
  • 10
    • 0015971739 scopus 로고
    • Injection method for ocular haemodynamic studies in man
    • Riva CE & Ben-Sira I (1974): Injection method for ocular haemodynamic studies in man. Invest Ophthalmol 13: 77-79.
    • (1974) Invest Ophthalmol. , vol.13 , pp. 77-79
    • Riva, C.E.1    Ben-Sira, I.2
  • 11
    • 0016570421 scopus 로고
    • Two-point fluorophotometer for the human ocular fundus
    • Riva CE & Ben-Sira I (1975): Two-point fluorophotometer for the human ocular fundus. Appl Optics 14: 2691-2693.
    • (1975) Appl. Optics , vol.14 , pp. 2691-2693
    • Riva, C.E.1    Ben-Sira, I.2
  • 12
    • 0017948920 scopus 로고
    • Fluorescein dye-dilution technique and retinal circulation
    • Riva CE, Feke GT & Ben-Sira I (1978): Fluorescein dye-dilution technique and retinal circulation. Am J Physiol 234: 315-322.
    • (1978) Am. J. Physiol. , vol.234 , pp. 315-322
    • Riva, C.E.1    Feke, G.T.2    Ben-Sira, I.3
  • 14
    • 0031449371 scopus 로고    scopus 로고
    • Retinal mean transit time determined with an Impulse-Response analysis from video fluorescein angiograms
    • Sperber GO & Alm A (1997): Retinal mean transit time determined with an Impulse-Response analysis from video fluorescein angiograms. Acta Ophthalmol Scand 75: 532-536.
    • (1997) Acta Ophthalmol. Scand. , vol.75 , pp. 532-536
    • Sperber, G.O.1    Alm, A.2
  • 15
    • 0001747857 scopus 로고
    • An empirical formula for indicator-dilution curves obtained in human beings
    • Stow RW & Hetzel PS (1954): An empirical formula for indicator-dilution curves obtained in human beings. J Appl Physiol 7: 161-167.
    • (1954) J. Appl. Physiol. , vol.7 , pp. 161-167
    • Stow, R.W.1    Hetzel, P.S.2
  • 16
    • 0035097899 scopus 로고    scopus 로고
    • Comparison of retinal transit times and retinal blood flow. A study in monkeys
    • Tomic L, Mäepea O, Sperber G & Alm A (2000): Comparison of retinal transit times and retinal blood flow. A study in monkeys. Invest Ophthalmol Vis Sci 42: 752-755.
    • (2000) Invest Ophthalmol. Vis. Sci. , vol.42 , pp. 752-755
    • Tomic, L.1    Mäepea, O.2    Sperber, G.3    Alm, A.4
  • 17
    • 0028438658 scopus 로고
    • Measurement of retinal haemodynamics with scanning laser ophthalmoscopy. Reference values and variation
    • May
    • Wolf S, Arend O & Reim M (1994): Measurement of retinal haemodynamics with scanning laser ophthalmoscopy. Reference values and variation. Survey Ophthalmol 38 (May Supplement): 95-100.
    • (1994) Survey Ophthalmol. , vol.38 , Issue.SUPPL. , pp. 95-100
    • Wolf, S.1    Arend, O.2    Reim, M.3
  • 19
    • 0015611439 scopus 로고
    • Fluorophotometric recording of fluorescein dilution curves in human retinal vessels
    • Ben-Sira I & Riva CE (1973): Fluorophotometric recording of fluorescein dilution curves in human retinal vessels. Invest Ophthalmol 12: 310-312.
    • (1973) Invest Ophthalmol. , vol.12 , pp. 310-312
    • Ben-Sira, I.1    Riva, C.E.2
  • 20
    • 85047679130 scopus 로고
    • Estimation of retinal blood flow by measurement of the mean circulation time
    • Bulpitt CJ & Dollery CT (1971): Estimation of retinal blood flow by measurement of the mean circulation time. Cardiovasc Res 5: 406-412.
    • (1971) Cardiovasc. Res. , vol.5 , pp. 406-412
    • Bulpitt, C.J.1    Dollery, C.T.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.