메뉴 건너뛰기




Volumn 16, Issue 12, 2002, Pages 1796-1801

Safe laparoscopic adhesiolysis with optical access trocar and ultrasonic dissection: A prospective study

Author keywords

Laparoscopic adhesiolysis; Optical trocar; Thermal perforations; Ultrasonic dissection

Indexed keywords

ABDOMINAL WALL; ADHESION; ARTICLE; DISSECTION; HEMOSTASIS; HUMAN; LAPAROSCOPIC SURGERY; LAPAROSCOPY; MAJOR CLINICAL STUDY; PRIORITY JOURNAL; ULTRASOUND;

EID: 0036913637     PISSN: 09302794     EISSN: 14322218     Source Type: Journal    
DOI: 10.1007/s00464-002-9021-5     Document Type: Article
Times cited : (16)

References (25)
  • 1
    • 0028213002 scopus 로고
    • The experimental development of an ultrasonically activated scalpel for laparoscopic use
    • Amaral JF (1994) The experimental development of an ultrasonically activated scalpel for laparoscopic use. Surg Endosc 4: 92-99
    • (1994) Surg Endosc , vol.4 , pp. 92-99
    • Amaral, J.F.1
  • 2
    • 0034073403 scopus 로고    scopus 로고
    • Are radially dilating trocars better than the alternatives?
    • Apelgren KN (2000) Are radially dilating trocars better than the alternatives? Surg Endosc 14: 317
    • (2000) Surg Endosc , vol.14 , pp. 317
    • Apelgren, K.N.1
  • 4
    • 0033803116 scopus 로고    scopus 로고
    • Is it necessary to lift the abdominal wall when preparing a pneumoperitoneum?
    • Briel JW, Plaisier PW, Meijer WS, Lange JF (2000) Is it necessary to lift the abdominal wall when preparing a pneumoperitoneum? Surg Endosc 14: 862-864
    • (2000) Surg Endosc , vol.14 , pp. 862-864
    • Briel, J.W.1    Plaisier, P.W.2    Meijer, W.S.3    Lange, J.F.4
  • 5
    • 0034987190 scopus 로고    scopus 로고
    • Major and minor injuries during the creation of pneumoperitoneum. A multicenter study on 12,919 cases
    • Catarci M, Carlini M, Gentileschi P, Santoro E (2001) Major and minor injuries during the creation of pneumoperitoneum. A multicenter study on 12,919 cases. Surg Endosc 15: 566-569
    • (2001) Surg Endosc , vol.15 , pp. 566-569
    • Catarci, M.1    Carlini, M.2    Gentileschi, P.3    Santoro, E.4
  • 6
    • 0027218226 scopus 로고
    • Laparoscopy using the left upper quadrant as the primary trocar site
    • Childers JM, Brzechffa PR, Surwit EA (1993) Laparoscopy using the left upper quadrant as the primary trocar site. Gynecol Oncol 50: 221-225
    • (1993) Gynecol Oncol , vol.50 , pp. 221-225
    • Childers, J.M.1    Brzechffa, P.R.2    Surwit, E.A.3
  • 8
    • 0030265822 scopus 로고    scopus 로고
    • Synergistic benefits of combined technologies in complex, minimally invasive surgical procedures: Experience and educational processes
    • Geis WP, Kim HC, McAfee PC, Kang JC, Brennan Jr EJ (1996) Synergistic benefits of combined technologies in complex, minimally invasive surgical procedures: Experience and educational processes. Surg Endosc 10: 1025-1028
    • (1996) Surg Endosc , vol.10 , pp. 1025-1028
    • Geis, W.P.1    Kim, H.C.2    McAfee, P.C.3    Kang, J.C.4    Brennan E.J., Jr.5
  • 11
    • 0031454819 scopus 로고    scopus 로고
    • Needle and trocar injury during laparoscopic surgery in Japan
    • Hashizume M, Sugimachi K (1997) Needle and trocar injury during laparoscopic surgery in Japan. Surg Endosc 11: 1198-1201
    • (1997) Surg Endosc , vol.11 , pp. 1198-1201
    • Hashizume, M.1    Sugimachi, K.2
  • 14
    • 0033042428 scopus 로고    scopus 로고
    • Experimental study on heat production by a 23.5-kHz ultrasonically activated device for endoscopic surgery
    • Kinoshita T, Kanehira E, Omura K, Kawakami K, Watanabe Y (1999) Experimental study on heat production by a 23.5-kHz ultrasonically activated device for endoscopic surgery. Surg Endosc 13: 621-625
    • (1999) Surg Endosc , vol.13 , pp. 621-625
    • Kinoshita, T.1    Kanehira, E.2    Omura, K.3    Kawakami, K.4    Watanabe, Y.5
  • 15
    • 0025798475 scopus 로고
    • Results of laparoscopic lysis of adhesions in patients with chronic pelvic pain
    • Kolmorgen K, Schulz AM (1991) Results of laparoscopic lysis of adhesions in patients with chronic pelvic pain. Zentralbl Gynaekol 113: 291-295
    • (1991) Zentralbl Gynaekol , vol.113 , pp. 291-295
    • Kolmorgen, K.1    Schulz, A.M.2
  • 16
    • 0016526492 scopus 로고
    • Indications, contraindications, and complications of laparoscopy
    • Loffler FD, Pent D (1975) Indications, contraindications, and complications of laparoscopy. Obstet Gynaecol Surg 30: 407-427
    • (1975) Obstet Gynaecol Surg , vol.30 , pp. 407-427
    • Loffler, F.D.1    Pent, D.2
  • 17
    • 0030798930 scopus 로고    scopus 로고
    • Subcostal insertion in the midclavicular line for primary insufflation and inspection in gynaecological laparoscopic surgery
    • Malik E, Stoz F, Möbus V, Kreienberg R (1997) Subcostal insertion in the midclavicular line for primary insufflation and inspection in gynaecological laparoscopic surgery. Geburts Frauenheilk 57: 388-390
    • (1997) Geburts Frauenheilk , vol.57 , pp. 388-390
    • Malik, E.1    Stoz, F.2    Möbus, V.3    Kreienberg, R.4
  • 18
    • 0029244284 scopus 로고
    • Access techniques: Veress needle-initial blind trocar introduction versus open laparoscopy with the Hasson trocar
    • McKernan JB, Champion JK (1995) Access techniques: Veress needle-initial blind trocar introduction versus open laparoscopy with the Hasson trocar. Endosc Surg Allied Technol 3: 35-38
    • (1995) Endosc Surg Allied Technol , vol.3 , pp. 35-38
    • McKernan, J.B.1    Champion, J.K.2
  • 20
    • 0029340117 scopus 로고
    • An evaluation of laparoscopic adhesiolysis in patients with chronic abdominal pain
    • Mueller MD, Tschudi J, Hermann U, Klaiber C (1995) An evaluation of laparoscopic adhesiolysis in patients with chronic abdominal pain. Surg Endosc 9: 802-804
    • (1995) Surg Endosc , vol.9 , pp. 802-804
    • Mueller, M.D.1    Tschudi, J.2    Hermann, U.3    Klaiber, C.4
  • 21
    • 0033986031 scopus 로고    scopus 로고
    • Ultrasonic coagulator for video-assisted internal mammary artery harvest
    • Ohtsuka T, Takamoto S, Endoh M, Kotsuka Y, Oka T (2000) Ultrasonic coagulator for video-assisted internal mammary artery harvest. Surg Endosc 14: 82-85
    • (2000) Surg Endosc , vol.14 , pp. 82-85
    • Ohtsuka, T.1    Takamoto, S.2    Endoh, M.3    Kotsuka, Y.4    Oka, T.5
  • 22
    • 0026538323 scopus 로고
    • Laparoscopic bowel injury
    • Reich H (1992) Laparoscopic bowel injury. Surg Laparosc Endosc 2: 74-78
    • (1992) Surg Laparosc Endosc , vol.2 , pp. 74-78
    • Reich, H.1
  • 23
    • 0031990905 scopus 로고    scopus 로고
    • The use of bipolar cautery, laparoscopic caogulating shears, and vascular clips for hemostasis of smaller and medium-sized vessels
    • Spivac H, Richardson WS, Hunter JGH (1998) The use of bipolar cautery, laparoscopic caogulating shears, and vascular clips for hemostasis of smaller and medium-sized vessels. Surg Endosc 12: 183-185
    • (1998) Surg Endosc , vol.12 , pp. 183-185
    • Spivac, H.1    Richardson, W.S.2    Hunter, J.G.H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.