Volumn , Issue , 2002, Pages 242-247

Physical-chemical oil tests, monitoring and diagnostics of oil-filled transformers

Author keywords

[No Author keywords available]

Indexed keywords

COSTS; ELECTRIC TRANSFORMER INSULATION; HEAT TRANSFER; MAINTENANCE;

EID: 0036912443     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (9)

References (18)
  • 1
    • 0003500359 scopus 로고
    • Specification for unused mineral insulating oils for transformers and switchgear
    • IEC 60296
    • IEC 60296 Specification for unused mineral insulating oils for transformers and switchgear, 1982
    • (1982)
  • 2
    • 0012113339 scopus 로고
    • Supervision and maintenance guide for mineral insulating oils in electrical equipment
    • IEC 60422
    • IEC 60422 Supervision and maintenance guide for mineral insulating oils in electrical equipment, 1989
    • (1989)
  • 3
    • 0003684693 scopus 로고    scopus 로고
    • Interpretation of the analysis of gases in transformers and other oil-filled electrical equipment in service
    • IEC60599
    • IEC60599 Interpretation of the analysis of gases in transformers and other oil-filled electrical equipment in service, 1999
    • (1999)
  • 4
    • 4243674887 scopus 로고
    • Guide for the sampling of gases and of oil from oil-filled electrical equipment and for the analysis of free and dissolved gases
    • IEC 60567
    • IEC 60567 Guide for the sampling of gases and of oil from oil-filled electrical equipment and for the analysis of free and dissolved gases, 1992
    • (1992)
  • 5
    • 0001921274 scopus 로고    scopus 로고
    • New guidelines for interpretation of dissolved gas analysis in oil-filled transformers
    • October
    • M̈ollmann A., Pahlavanpour B. "New Guidelines for Interpretation of Dissolved Gas Analysis in Oil-Filled Transformers", Electra No. 186, October 1999, pp. 31-51
    • (1999) Electra No. 186 , pp. 31-51
    • M̈ollmann, A.1    Pahlavanpour, B.2
  • 7
    • 0012149590 scopus 로고    scopus 로고
    • Study of correlations of on-line diagnostic methods on power transformers
    • December; (in Slovene)
    • Varl A., Končn-Granik M., Study of correlations of on-line diagnostic methods on power transformers, Elektroinštitut Milan Vidmar, December 2001, p. 44 (in Slovene).
    • (2001) Elektroinštitut Milan Vidmar , pp. 44
    • Varl, A.1    Končn-Granik, M.2
  • 8
    • 0012188024 scopus 로고    scopus 로고
    • On-line diagnostic of oil filled transformers, ICDL
    • Provisional Subject 4, Paper Number 45
    • Varl A., On-line diagnostic of Oil Filled Transformers, ICDL 2002, Provisional Subject 4, Paper Number 45.
    • (2002)
    • Varl, A.1
  • 9
    • 0003632316 scopus 로고
    • Mineral insulating oils-Methods for the determination of 2-furfural and related compounds
    • IEC 61198
    • IEC 61198 Mineral insulating oils-Methods for the determination of 2-furfural and related compounds, 1993
    • (1993)
  • 10
    • 0002416206 scopus 로고    scopus 로고
    • Furanic compounds analysis:A tool for predictive maintenance of oil-filled electrical equipment
    • December
    • A.De Pablo, B.Pahlavanpour "Furanic Compounds Analysis:A Tool for Predictive Maintenance of Oil-Filled Electrical Equipment", Electra No.175, December 1997, pp. 9-32
    • (1997) Electra No.175 , pp. 9-32
    • De Pablo, A.1    Pahlavanpour, B.2
  • 12
    • 0012189627 scopus 로고    scopus 로고
    • A study of ageing of paper insulation in transformers with liquid chromatography
    • Elektroinštitut Milan Vidmar; (in Slovene)
    • Končan-Gradnik M., A Study of Ageing of Paper Insulation in Transformers with Liquid Chromatography, Elektroinštitut Milan Vidmar, 1996 (in Slovene).
    • (1996)
    • Končan-Gradnik, M.1
  • 13
    • 0012112345 scopus 로고    scopus 로고
    • A study of effect of transformer oil quality on paper insulation degradation
    • Elektroinštitut Milan Vidmar; (in Slovene)
    • Varl A., A Study of Effect of Transformer Oil Quality on Paper Insulation Degradation, Elektroinštitut Milan Vidmar, 1997, (in Slovene).
    • (1997)
    • Varl, A.1
  • 14
    • 0012187106 scopus 로고    scopus 로고
    • A study of influences on the relationship between furans dissolved in oil and ageing of paper of transformer
    • December; (in Slovene)
    • Končan-Gradnik M., Mulej M., Varl A., A Study of Influences on the Relationship Between Furans Dissolved in Oil and Ageing of Paper of Transformer, Electroinštitut Milan Vidmar, December 1998, p. 48 (in Slovene).
    • (1998) Electroinštitut Milan Vidmar , vol.48
    • Končan-Gradnik, M.1    Mulej, M.2    Varl, A.3
  • 18
    • 4243401474 scopus 로고    scopus 로고
    • Quality assurance system of transformer diagnostics laboratories
    • ICDL; Provisional Subject 4, Paper Number 44
    • Mulej M., Končan-Gradnik M., Quality assurance system of transformer diagnostics laboratories, ICDL 2002, Provisional Subject 4, Paper Number 44.
    • (2002)
    • Mulej, M.1    Končan-Gradnik, M.2