Effects of Clarion electrode design on mapping levels in children

Author keywords

Child; Cochlear implant; Electrode impedance; Modiolar proximity

Indexed keywords

ADOLESCENT; ARTICLE; CHILD; COCHLEA PROSTHESIS; ELECTRODE; EVOKED AUDITORY RESPONSE; FEMALE; HUMAN; IMPEDANCE; IMPLANT; IMPLANTATION; MAJOR CLINICAL STUDY; MALE; OUTCOMES RESEARCH; PRIORITY JOURNAL; PSYCHOPHYSIOLOGY; STIMULUS RESPONSE; YOUNG MODULUS;

EID: 0036912296     PISSN: 00034894     EISSN: None     Source Type: Journal    
DOI: 10.1177/000348940211101212     Document Type: Article
Times cited : (9)

References (10)
  • 1
    • 0029950105 scopus 로고    scopus 로고
    • Spatial selectivity in a rotationally symmetric model of the electrically stimulated cochlea
    • Frijns JH, de Snoo SL, ten Kate JH. Spatial selectivity in a rotationally symmetric model of the electrically stimulated cochlea. Hear Res 1996;95:33-48.
    • (1996) Hear Res , vol.95 , pp. 33-48
    • Frijns, J.H.1    De Snoo, S.L.2    Ten Kate, J.H.3
  • 2
    • 0029123279 scopus 로고
    • Effects of electrical current configuration on potential fields in the electrically stimulated cochlea: Field models and measurements
    • Spelman FA, Pfingst BE, Clopton BM, Jolly CN, Rodenhiser KL. Effects of electrical current configuration on potential fields in the electrically stimulated cochlea: Field models and measurements. Ann Otol Rhinol Laryngol Suppl 1995; 104 (suppl 166):131-6.
    • (1995) Ann Otol Rhinol Laryngol Suppl , vol.104 , Issue.SUPPL. 166 , pp. 131-136
    • Spelman, F.A.1    Pfingst, B.E.2    Clopton, B.M.3    Jolly, C.N.4    Rodenhiser, K.L.5
  • 3
    • 0027503532 scopus 로고
    • Electrical stimulation of the auditory nerve: The effect of electrode position on neural excitation
    • Shepherd RK, Hatsushika S, Clark GM. Electrical stimulation of the auditory nerve: The effect of electrode position on neural excitation. Hear Res 1993;66:108-20.
    • (1993) Hear Res , vol.66 , pp. 108-120
    • Shepherd, R.K.1    Hatsushika, S.2    Clark, G.M.3
  • 4
    • 0032940987 scopus 로고    scopus 로고
    • The CLARION Multi-Strategy Cochlear Implant
    • Kessler DK. The CLARION Multi-Strategy Cochlear Implant. Ann Otol Rhinol Laryngol Suppl 1999;108(suppl 177):8-16.
    • (1999) Ann Otol Rhinol Laryngol Suppl , vol.108 , Issue.SUPPL. 177 , pp. 8-16
    • Kessler, D.K.1
  • 5
    • 0034054761 scopus 로고    scopus 로고
    • The Clarion electrode positioner: Temporal bone studies
    • Fayad JN, Luxford W, Linthicum FH. The Clarion electrode positioner: Temporal bone studies. Am J Otol 2000;21:226-9.
    • (2000) Am J Otol , vol.21 , pp. 226-229
    • Fayad, J.N.1    Luxford, W.2    Linthicum, F.H.3
  • 6
    • 0034032485 scopus 로고    scopus 로고
    • Comparison of EAP thresholds with MAP levels in the Nucleus 24 cochlear implant: Data from children
    • Hughes ML, Brown CJ, Abbas PJ, Wolaver AA, Gervais JP. Comparison of EAP thresholds with MAP levels in the Nucleus 24 cochlear implant: Data from children. Ear Hear 2000;21:164-74.
    • (2000) Ear Hear , vol.21 , pp. 164-174
    • Hughes, M.L.1    Brown, C.J.2    Abbas, P.J.3    Wolaver, A.A.4    Gervais, J.P.5
  • 7
    • 0020997717 scopus 로고
    • Chronic electrical stimulation of the auditory nerve in cats. Physiological and histopathological results
    • Shepherd RK, Clark GM, Black RC. Chronic electrical stimulation of the auditory nerve in cats. Physiological and histopathological results. Acta Otolaryngol Suppl (Stockh) 1983(suppl 399):19-31.
    • (1983) Acta Otolaryngol Suppl (Stockh) , Issue.SUPPL. 399 , pp. 19-31
    • Shepherd, R.K.1    Clark, G.M.2    Black, R.C.3
  • 8
    • 0012115296 scopus 로고
    • Histopathology of cochlear implants: Safety considerations
    • Schindler RA, Merzenich MM, eds. New York, NY: Raven Press
    • Leake PA, Rebscher SJ, Aird DW. Histopathology of cochlear implants: Safety considerations. In: Schindler RA, Merzenich MM, eds. Cochlear Implants. New York, NY: Raven Press, 1985:55-64.
    • (1985) Cochlear Implants , pp. 55-64
    • Leake, P.A.1    Rebscher, S.J.2    Aird, D.W.3
  • 9
    • 0017367642 scopus 로고
    • Electrochemical considerations for safe electrical stimulation of the nervous system with platinum electrodes
    • Brummer SB, Turner MJ. Electrochemical considerations for safe electrical stimulation of the nervous system with platinum electrodes. IEEE Trans Biomed Eng 1977;24:59-63.
    • (1977) IEEE Trans Biomed Eng , vol.24 , pp. 59-63
    • Brummer, S.B.1    Turner, M.J.2
  • 10
    • 0033049533 scopus 로고    scopus 로고
    • Reduction in excitability of the auditory nerve following electrical stimulation at high stimulus rates. IV. Effects of stimulus intensity
    • Huang CQ, Shepherd RK. Reduction in excitability of the auditory nerve following electrical stimulation at high stimulus rates. IV. Effects of stimulus intensity. Hear Res 1999;132: 60-8.
    • (1999) Hear Res , vol.132 , pp. 60-68
    • Huang, C.Q.1    Shepherd, R.K.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.