Volumn 40, Issue , 2002, Pages 387-397

Lubrication and wear of alumina-alumina hip bearings

Author keywords

[No Author keywords available]

Indexed keywords

ALUMINUM;

EID: 0036909625     PISSN: 01678922     EISSN: None     Source Type: Book Series    
DOI: 10.1016/s0167-8922(02)80043-8     Document Type: Conference Paper
Times cited : (1)

References (22)
  • 2
    • 0026761335 scopus 로고
    • On the material and the tribology of alumina-alumina couplings for hip joint prostheses
    • Walter, A. On the material and the tribology of alumina-alumina couplings for hip joint prostheses. Clin Orthop, 1992, 282, 31-46.
    • (1992) Clin Orthop , vol.282 , pp. 31-46
    • Walter, A.1
  • 3
    • 0000242627 scopus 로고    scopus 로고
    • Ex vivo and in vitro analysis of the alumina/alumina bearing system for hip joint prostheses
    • Refior, H.J., Plitz, W. and Walter, A. Ex vivo and in vitro analysis of the alumina/alumina bearing system for hip joint prostheses. Bioceramics, 1997, 10, 127-130.
    • (1997) Bioceramics , vol.10 , pp. 127-130
    • Refior, H.J.1    Plitz, W.2    Walter, A.3
  • 4
    • 0031940455 scopus 로고    scopus 로고
    • Review - Ceramics for total hip replacement - What a surgeon should know
    • Willman, G. Review - ceramics for total hip replacement - what a surgeon should know. Orthopedics, 1998, 21 (2), 173-177.
    • (1998) Orthopedics , vol.21 , Issue.2 , pp. 173-177
    • Willman, G.1
  • 5
    • 0033814067 scopus 로고    scopus 로고
    • Microseparation of the centers of alumina-alumina artificial hip joints during simulator testing produces clinically relevant wear rates and patterns
    • Nevelos, J., Ingham, E., Doyle, C., Streicher, R., Nevelos, A., Walter, W. and Fisher, J. Microseparation of the centers of alumina-alumina artificial hip joints during simulator testing produces clinically relevant wear rates and patterns. Journal of Arthroplasty, 2000, 15 (6), 2000, 793-795.
    • (2000) Journal of Arthroplasty , vol.15 , Issue.6 , pp. 793-795
    • Nevelos, J.1    Ingham, E.2    Doyle, C.3    Streicher, R.4    Nevelos, A.5    Walter, W.6    Fisher, J.7
  • 6
    • 0003020289 scopus 로고    scopus 로고
    • Influence of acetabular cup angle on the wear of 'Biolox Forte' alumina/alumina hip joints in a physiological simulator
    • Anaheim, CA
    • th ORS, 1999, Anaheim, CA, 857.
    • (1999) th ORS , pp. 857
    • Nevelos, J.1    Ingham, E.2    Doyle, C.3    Fisher, J.4
  • 7
    • 0013328244 scopus 로고    scopus 로고
    • Wear of HIPped and non-HIPped alumina-alumina hip joints under standard and harsh simulator testing conditions
    • Kamula, Hawaii
    • Nevelos, J., Ingham. E., Doyle. C., Nevelos. A and Fisher J. Wear of HIPped and non-HIPped alumina-alumina hip joints under standard and harsh simulator testing conditions, Trans. 6th World Biomaterials Congress, 2000, Kamula, Hawaii, 875.
    • (2000) Trans. 6th World Biomaterials Congress , pp. 875
    • Nevelos, J.1    Ingham, E.2    Doyle, C.3    Nevelos, A.4    Fisher, J.5
  • 10
    • 0002544024 scopus 로고    scopus 로고
    • In-vitro wear performance of a contemporary alumina: Alumina bearing couple under anatomically-relevant hip joint simulation
    • Oct. 1-2, San Francisco
    • Taylor, S.K. In-vitro wear performance of a contemporary alumina: alumina bearing couple under anatomically-relevant hip joint simulation. Ceramtec Imposium, Oct. 1-2, 1999, San Francisco, 85-90.
    • (1999) Ceramtec Imposium , pp. 85-90
    • Taylor, S.K.1
  • 12
    • 0031726123 scopus 로고    scopus 로고
    • Low wear and friction in alumina/alumina total hip joints - A hip simulator study
    • Saikko, V. and Pfaff, H-G. Low wear and friction in alumina/alumina total hip joints - A hip simulator study. Acta Orthop. Scand., 1998, 69 (5), 443-448.
    • (1998) Acta Orthop. Scand. , vol.69 , Issue.5 , pp. 443-448
    • Saikko, V.1    Pfaff, H.-G.2
  • 15
    • 0023734853 scopus 로고
    • Biomechanical compatibility and design of ceramic implants for orthopaedic surgery. Bioceramics: Material characteristics versus in vivo behaviour
    • Christel P., Meunier, A. and Dorlot, J-M. Biomechanical compatibility and design of ceramic implants for orthopaedic surgery. Bioceramics: material characteristics versus in vivo behaviour. Ann NY Acad Sci, 1988, 523, 234-256.
    • (1988) Ann NY Acad Sci , vol.523 , pp. 234-256
    • Christel, P.1    Meunier, A.2    Dorlot, J.-M.3
  • 16
    • 0026768743 scopus 로고
    • Long-term effects of alumina components in total hip prostheses
    • Dorlot, J. Long-term effects of alumina components in total hip prostheses. Clin Orthop, 1992, 282, 47-52.
    • (1992) Clin Orthop , vol.282 , pp. 47-52
    • Dorlot, J.1
  • 17
    • 0030627631 scopus 로고    scopus 로고
    • Analysis of fluid film lubrication in artificial hip joint replacements with surfaces of high elastic modulus
    • Jin, Z.M., Dowson, D. and Fisher, J. Analysis of fluid film lubrication in artificial hip joint replacements with surfaces of high elastic modulus, IMECHE J. Eng. in Med., 1997, 211 (3), 247-256.
    • (1997) IMECHE J. Eng. in Med. , vol.211 , Issue.3 , pp. 247-256
    • Jin, Z.M.1    Dowson, D.2    Fisher, J.3
  • 18
    • 0000739709 scopus 로고    scopus 로고
    • Numerical analysis of time-varying fluid film thickness in metal-metal hip implants in simulator tests
    • Chan, F.W., Medley, J.B., Bobyn, J.D. and Krygier, J.J. Numerical analysis of time-varying fluid film thickness in metal-metal hip implants in simulator tests, ASTM STP 1346, 1998, 111-128.
    • (1998) ASTM STP , vol.1346 , pp. 111-128
    • Chan, F.W.1    Medley, J.B.2    Bobyn, J.D.3    Krygier, J.J.4
  • 19
    • 0030210397 scopus 로고    scopus 로고
    • Comparison of alloys and designs in a hip simulator study of metal-metal implants
    • Medley, J.B., Chan, F.W., Krygier, J.J. and Bobyn, J.D. Comparison of alloys and designs in a hip simulator study of metal-metal implants, Clin Orthop, 1996, 329 Suppl., S148-S159.1
    • (1996) Clin Orthop , vol.329 , Issue.SUPPL.
    • Medley, J.B.1    Chan, F.W.2    Krygier, J.J.3    Bobyn, J.D.4
  • 20
    • 0001566621 scopus 로고    scopus 로고
    • Simulator wear of some commercially available metal on metal hip implants
    • Medley, J.B., Dowling, J.M., Poggie, R.A., Krygier, J.J. and Bobyn, J.D. Simulator wear of some commercially available metal on metal hip implants. ASTM STP 1346, 1998, 92-110.
    • (1998) ASTM STP , vol.1346 , pp. 92-110
    • Medley, J.B.1    Dowling, J.M.2    Poggie, R.A.3    Krygier, J.J.4    Bobyn, J.D.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.