메뉴 건너뛰기




Volumn 47, Issue 12, 2002, Pages 323-325

Bone fixation strength of hydroxyapatite-coated Schanz screws of the Heidelberg External Fixation System (HEFS) - Determination of torque in clinical application and in a Cadaveric Tibia;Zur knöchernen verankerungsfestigkeit hydroxylapatitbeschichteter schanz-schrauben des Heidelberg External Fixation Systems (HEFS) - Vergleichende drehmomentmessungen im klinischen Einsatz und an der Leichentibia

Author keywords

Callotasis; Heidelberg External Fixation System; Hydroxyapatite coating; Schanz screws

Indexed keywords

BIOCOMPATIBILITY; BONE; HYDROXYAPATITE; ORTHOPEDICS; TORQUE;

EID: 0036908248     PISSN: 00135585     EISSN: None     Source Type: Journal    
DOI: 10.1515/bmte.2002.47.12.323     Document Type: Article
Times cited : (1)

References (13)
  • 2
    • 0029311018 scopus 로고
    • Increase of stability in fracture fixation by hydroxyapatite-coated bone screws
    • Augat, P., L. Claes, K. F. Hanselmann, G. Suger, W. Fleischmann: Increase of stability in fracture fixation by hydroxyapatite-coated bone screws. J. Appl. Biomater. 6: 99-104 (1995).
    • (1995) J. Appl. Biomater. , vol.6 , pp. 99-104
    • Augat, P.1    Claes, L.2    Hanselmann, K.F.3    Suger, G.4    Fleischmann, W.5
  • 4
    • 0027502660 scopus 로고
    • Der Einfluβ der Hydroxylapatit-Beschichtung von AO/ASIF-Schrauben auf die Haftfestigkeit im Knochen
    • Dávid, A., A. Pommer, J. Eitenmüller, G. Muhr: Der Einfluβ der Hydroxylapatit-Beschichtung von AO/ASIF-Schrauben auf die Haftfestigkeit im Knochen. Unfallchirurg 96: 12-17 (1993).
    • (1993) Unfallchirurg , vol.96 , pp. 12-17
    • Dávid, A.1    Pommer, A.2    Eitenmüller, J.3    Muhr, G.4
  • 7
    • 0024555042 scopus 로고
    • The tension-stress effect on the genesis and growth of tissues. Part 1: The influence of stability of fixation and soft-tissue preservation
    • Ilizarov, G. A.: The tension-stress effect on the genesis and growth of tissues. Part 1: The influence of stability of fixation and soft-tissue preservation. Clin. Orthop. 238: 249-281 (1989).
    • (1989) Clin. Orthop. , vol.238 , pp. 249-281
    • Ilizarov, G.A.1
  • 8
    • 0030968773 scopus 로고    scopus 로고
    • Hydroxyapatite coating of threaded pins enhances fixation
    • Magyar, G., S. Toksvig-Larsen, A. Moroni: Hydroxyapatite coating of threaded pins enhances fixation. J. Bone Joint Surg. [Br], 79-B: 487-489 (1997).
    • (1997) J. Bone Joint Surg. [Br] , vol.79 B , pp. 487-489
    • Magyar, G.1    Toksvig-Larsen, S.2    Moroni, A.3
  • 11
    • 0000578133 scopus 로고    scopus 로고
    • Improvement of the bone-pin interface strength in osteoporotic bone with use of hydroxyapatite-coated tapered external-fixation pins
    • Moroni, A., C. Faldini, S. Marchetti, M. Manca, V. Consoli, S. Giannini: Improvement of the bone-pin interface strength in osteoporotic bone with use of hydroxyapatite-coated tapered external-fixation pins. J. Bone Joint Surg. [Am], 83-A, 717-721 (2001).
    • (2001) J. Bone Joint Surg. [Am] , vol.83 A , pp. 717-721
    • Moroni, A.1    Faldini, C.2    Marchetti, S.3    Manca, M.4    Consoli, V.5    Giannini, S.6
  • 12
    • 0034963773 scopus 로고    scopus 로고
    • Evaluation hydroxylapatitbeschichteter Schanz-Schrauben bei Verwendung des Heidelberg External Fixation Systems (HEFS)
    • Placzek, R., A. Hempfing, A. L. Meiss: Evaluation hydroxylapatitbeschichteter Schanz-Schrauben bei Verwendung des Heidelberg External Fixation Systems (HEFS). Evaluation of hydroxyapatite-coated Schanz screws used in the Heidelberg External Fixation System (HEFS). Biomed. Technik, 46, 172-175 (2001).
    • (2001) Biomed. Technik. , vol.46 , pp. 172-175
    • Placzek, R.1    Hempfing, A.2    Meiss, A.L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.