메뉴 건너뛰기




Volumn 17, Issue 8, 2002, Pages 987-991

A study of polyethylene and modularity issues in >1, 000 posterior cruciate-retaining knees at 5 to 11 years

Author keywords

Arthroplasty; Design; Knee; Modularity; Polyethylene

Indexed keywords

POLYETHYLENE;

EID: 0036905222     PISSN: 08835403     EISSN: None     Source Type: Journal    
DOI: 10.1054/arth.2002.35797     Document Type: Article
Times cited : (24)

References (34)
  • 1
    • 0031718703 scopus 로고    scopus 로고
    • The incidence of modular tibial polyethylene insert exchange in total knee arthroplasty when polyethylene failure occurs
    • Bert JM, Reuben J, Kelly F, et al: The incidence of modular tibial polyethylene insert exchange in total knee arthroplasty when polyethylene failure occurs. J Arthroplasty 13:609, 1998
    • (1998) J Arthroplasty , vol.13 , pp. 609
    • Bert, J.M.1    Reuben, J.2    Kelly, F.3
  • 2
    • 0026527293 scopus 로고
    • Polyethylene wear of metal-backed tibial components in total and uni-compartmental knee prostheses
    • Engh GA, Dwyer KA, Hanes CK: Polyethylene wear of metal-backed tibial components in total and uni-compartmental knee prostheses. J Bone Joint Surg Br 71:9, 1992
    • (1992) J Bone Joint Surg Br , vol.71 , pp. 9
    • Engh, G.A.1    Dwyer, K.A.2    Hanes, C.K.3
  • 3
    • 0028566198 scopus 로고
    • Tibial osteolysis in cementless total knee arthroplasty: A review of 25 cases treated with and without tibial component revision
    • Engh GA, Parks NL, Ammeen DJ: Tibial osteolysis in cementless total knee arthroplasty: A review of 25 cases treated with and without tibial component revision. Clin Orthop 309:33, 1994
    • (1994) Clin Orthop , vol.309 , pp. 33
    • Engh, G.A.1    Parks, N.L.2    Ammeen, D.J.3
  • 4
    • 0029973991 scopus 로고    scopus 로고
    • Characterization of debris adjacent to failed knee implants of 3 different designs
    • Hirakawa K, Bauer TW, Stulberg BN, et al: Characterization of debris adjacent to failed knee implants of 3 different designs. Clin Orthop 331:151, 1996
    • (1996) Clin Orthop , vol.331 , pp. 151
    • Hirakawa, K.1    Bauer, T.W.2    Stulberg, B.N.3
  • 5
    • 0023860303 scopus 로고
    • A rat model of resorption of bone at the cement-bone interface in the presence of polyethylene wear particles
    • Howie DW, Vernon-Roberts B, Oakeshott R, Manthey B: A rat model of resorption of bone at the cement-bone interface in the presence of polyethylene wear particles. J Bone Joint Surg Am 70:257, 1988
    • (1988) J Bone Joint Surg Am , vol.70 , pp. 257
    • Howie, D.W.1    Vernon-Roberts, B.2    Oakeshott, R.3    Manthey, B.4
  • 7
    • 0028008566 scopus 로고
    • Posteromedial final polyethylene failure in total knee replacements
    • Lewis P, Rorabeck CH, Bourne RB, Devane P: Posteromedial final polyethylene failure in total knee replacements. Clin Orthop 299:11, 1994
    • (1994) Clin Orthop , vol.299 , pp. 11
    • Lewis, P.1    Rorabeck, C.H.2    Bourne, R.B.3    Devane, P.4
  • 8
    • 0026386787 scopus 로고
    • Survivorship analysis of the uncemented Porous-Coated Anatomic knee replacement
    • Moran CG, Pinder IM, Lees TA, Midwinter MJ: Survivorship analysis of the uncemented Porous-Coated Anatomic knee replacement. J Bone Joint Surg Am 73:848, 1991
    • (1991) J Bone Joint Surg Am , vol.73 , pp. 848
    • Moran, C.G.1    Pinder, I.M.2    Lees, T.A.3    Midwinter, M.J.4
  • 9
    • 0026569950 scopus 로고
    • Aggressive granulomatosis from polyethylene failure in an uncemented knee replacement
    • Nolan JF, Bucknill TM: Aggressive granulomatosis from polyethylene failure in an uncemented knee replacement. J Bone Joint Surg Br 74:23, 1992
    • (1992) J Bone Joint Surg Br , vol.74 , pp. 23
    • Nolan, J.F.1    Bucknill, T.M.2
  • 11
    • 0027497632 scopus 로고
    • Failure of the Porous-Coated Anatomic prosthesis in total knee arthroplasty due to severe polyethylene wear
    • Tsao A, Mintz L, McRae CR, et al: Failure of the Porous-Coated Anatomic prosthesis in total knee arthroplasty due to severe polyethylene wear. J Bone Joint Surg Am 75:19, 1993
    • (1993) J Bone Joint Surg Am , vol.75 , pp. 19
    • Tsao, A.1    Mintz, L.2    McRae, C.R.3
  • 13
    • 0031043864 scopus 로고    scopus 로고
    • Posterior cruciate recession in total knee arthroplasty
    • Worland RL, Jessup DE, Johnson J: Posterior cruciate recession in total knee arthroplasty. J Arthroplasty 12:70, 1997
    • (1997) J Arthroplasty , vol.12 , pp. 70
    • Worland, R.L.1    Jessup, D.E.2    Johnson, J.3
  • 14
    • 0032944703 scopus 로고    scopus 로고
    • Radiolucent lines: A question of nomenclature
    • Freeman MAR: Radiolucent lines: A question of nomenclature (editorial). J Arthroplasty 14:1, 1999
    • (1999) J Arthroplasty , vol.14 , pp. 1
    • Freeman, M.A.R.1
  • 15
    • 0024950156 scopus 로고
    • The Knee Society total knee arthroplasty roentgenographic evaluation and scoring system
    • Ewald FC: The Knee Society total knee arthroplasty roentgenographic evaluation and scoring system. Clin Orthop 248:9, 1989
    • (1989) Clin Orthop , vol.248 , pp. 9
    • Ewald, F.C.1
  • 16
    • 0029076309 scopus 로고
    • Survivorship analysis of cemented total condylar knee arthroplasty
    • Falatyn S, Lachiewicz PF, Wilson FC: Survivorship analysis of cemented total condylar knee arthroplasty. Clin Orthop 317:178, 1995
    • (1995) Clin Orthop , vol.317 , pp. 178
    • Falatyn, S.1    Lachiewicz, P.F.2    Wilson, F.C.3
  • 17
    • 0027478984 scopus 로고
    • Long-term results of the Total Condylar knee arthroplasty: A 15 year survivorship study
    • Ranawat CS, Flynn WF, Saddler S, et al: Long-term results of the Total Condylar knee arthroplasty: A 15 year survivorship study. Clin Orthop 286:94, 1993
    • (1993) Clin Orthop , vol.286 , pp. 94
    • Ranawat, C.S.1    Flynn, W.F.2    Saddler, S.3
  • 21
    • 0023697318 scopus 로고
    • Wear of ultra high molecular weight polyethylene components of 90 retrieved knee prostheses
    • Landy M, Walker PS: Wear of ultra high molecular weight polyethylene components of 90 retrieved knee prostheses. J Arthroplasty 3(suppl):73, 1988
    • (1988) J Arthroplasty , vol.3 , pp. 73
    • Landy, M.1    Walker, P.S.2
  • 22
    • 0028100192 scopus 로고
    • The Swedish knee arthroplasty register: A nation-wide study of 30, 003 knees 1976-1992
    • Knutson K, Lewold S, Robertsson O, Lidgren L: The Swedish knee arthroplasty register: A nation-wide study of 30, 003 knees 1976-1992. Acta Orthop Scand 65:375, 1994
    • (1994) Acta Orthop Scand , vol.65 , pp. 375
    • Knutson, K.1    Lewold, S.2    Robertsson, O.3    Lidgren, L.4
  • 23
    • 0028838566 scopus 로고
    • Flat-on-flat, nonconstrained, compression molded polyethylene total knee replacement
    • Ritter MA, Worland RL, Saliski J, et al: Flat-on-flat, nonconstrained, compression molded polyethylene total knee replacement. Clin Orthop 321:79, 1995
    • (1995) Clin Orthop , vol.321 , pp. 79
    • Ritter, M.A.1    Worland, R.L.2    Saliski, J.3
  • 24
    • 0034959851 scopus 로고    scopus 로고
    • Long term follow up of anatomic graduated component posterior cruciate-retaining total knee replacement
    • Ritter MA, Berend ME, Meding JB, et al: Long term follow up of anatomic graduated component posterior cruciate-retaining total knee replacement. Clin Orthop 388:51, 2001
    • (2001) Clin Orthop , vol.388 , pp. 51
    • Ritter, M.A.1    Berend, M.E.2    Meding, J.B.3
  • 25
    • 0036200468 scopus 로고    scopus 로고
    • Ten to fourteen year survival and functional analysis of the AGC total knee replacement system
    • Worland RL, Johnson G, Alemparte J, et al: Ten to fourteen year survival and functional analysis of the AGC total knee replacement system. Knee 9:133, 2002
    • (2002) Knee , vol.9 , pp. 133
    • Worland, R.L.1    Johnson, G.2    Alemparte, J.3
  • 26
    • 0027954306 scopus 로고
    • Progressive subluxation and polyethylene wear in total knee replacements with flat articular surfaces
    • Feng EL, Stulberg SD, Wixson RL: Progressive subluxation and polyethylene wear in total knee replacements with flat articular surfaces. Clin Orthop 299:60, 1994
    • (1994) Clin Orthop , vol.299 , pp. 60
    • Feng, E.L.1    Stulberg, S.D.2    Wixson, R.L.3
  • 27
    • 0031823774 scopus 로고    scopus 로고
    • Case report: Osteolysis associated with cemented total knee arthroplasty
    • Griffin FM, Scuderi GR, Gillis AM, et al: Case report: Osteolysis associated with cemented total knee arthroplasty. J Arthroplasty 13:592, 1998
    • (1998) J Arthroplasty , vol.13 , pp. 592
    • Griffin, F.M.1    Scuderi, G.R.2    Gillis, A.M.3
  • 28
    • 0026346472 scopus 로고
    • Analysis of the failure of 122 polyethylene inserts from uncemented tibial knee components
    • Collier JP, Mayor MB, McNamara JL, et al: Analysis of the failure of 122 polyethylene inserts from uncemented tibial knee components. Clin Orthop 273:232, 1991
    • (1991) Clin Orthop , vol.273 , pp. 232
    • Collier, J.P.1    Mayor, M.B.2    McNamara, J.L.3
  • 30
    • 0028785801 scopus 로고
    • Catastrophic osteolysis in total knee replacement: A report of 17 cases
    • Robinson EJ, Mulliken BD, Bourne RB, et al: Catastrophic osteolysis in total knee replacement: A report of 17 cases. Clin Orthop 321:98, 1995
    • (1995) Clin Orthop , vol.321 , pp. 98
    • Robinson, E.J.1    Mulliken, B.D.2    Bourne, R.B.3
  • 31
    • 0028046997 scopus 로고
    • Osteolysis associated with cemented total knee arthroplasty: A case report
    • Ries MD, Guiney W, Lynch F: Osteolysis associated with cemented total knee arthroplasty: A case report. J Arthroplasty 9:555, 1994
    • (1994) J Arthroplasty , vol.9 , pp. 555
    • Ries, M.D.1    Guiney, W.2    Lynch, F.3
  • 32
    • 0028849719 scopus 로고
    • Effect of component fixation method on osteolysis in total knee arthroplasty
    • Ezzet KA, Garcia R, Barrack RL: Effect of component fixation method on osteolysis in total knee arthroplasty. Clin Orthop 321:86, 1995
    • (1995) Clin Orthop , vol.321 , pp. 86
    • Ezzet, K.A.1    Garcia, R.2    Barrack, R.L.3
  • 33
    • 0032923984 scopus 로고    scopus 로고
    • The natural history of tibial radiolucent lines in a proximally cemented stemmed total knee arthroplasty
    • Smith S, Naima VSN, Freeman MAR: The natural history of tibial radiolucent lines in a proximally cemented stemmed total knee arthroplasty. J Arthroplasty 14:3, 1999
    • (1999) J Arthroplasty , vol.14 , pp. 3
    • Smith, S.1    Naima, V.S.N.2    Freeman, M.A.R.3
  • 34
    • 0024367872 scopus 로고
    • A comparison of plain and fluoroscopically guided radiographs in the assessment of arthroplasty of the knee
    • Mintz AD, Pilkington CAJ, Howie DW: A comparison of plain and fluoroscopically guided radiographs in the assessment of arthroplasty of the knee. J Bone Joint Surg Am 71:1343, 1989
    • (1989) J Bone Joint Surg Am , vol.71 , pp. 1343
    • Mintz, A.D.1    Pilkington, C.A.J.2    Howie, D.W.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.