메뉴 건너뛰기




Volumn 74, Issue 6, 2002, Pages 2022-2025

Nineteen-millimeter prosthetic aortic valves allow normalization of left ventricular mass in elderly women

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ANGINA PECTORIS; AORTA VALVE DISEASE; AORTA VALVE PROSTHESIS; AORTA VALVE REPLACEMENT; ARTICLE; CLINICAL ARTICLE; CONTROLLED STUDY; CORONARY ARTERY BYPASS GRAFT; ECHOCARDIOGRAPHY; FEMALE; FOLLOW UP; HEART LEFT VENTRICLE MASS; HEMODYNAMICS; HUMAN; MEDICAL SOCIETY; PATIENT SATISFACTION; POSTOPERATIVE PERIOD; PREOPERATIVE PERIOD; PRIORITY JOURNAL; SURGICAL MORTALITY; SURVIVAL;

EID: 0036900903     PISSN: 00034975     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0003-4975(02)04079-1     Document Type: Article
Times cited : (28)

References (18)
  • 1
    • 0018104133 scopus 로고
    • The problem of valve prosthesis-patient mismatch
    • Rahimtoola SH. The problem of valve prosthesis-patient mismatch. Circulation 1978;58:20-4.
    • (1978) Circulation , vol.58 , pp. 20-24
    • Rahimtoola, S.H.1
  • 2
    • 0033819953 scopus 로고    scopus 로고
    • Hemodynamic and clinical impact of prosthesis-patient mismatch in the aortic valve position and its prevention
    • Pibarot P, Dumesnil JG. Hemodynamic and clinical impact of prosthesis-patient mismatch in the aortic valve position and its prevention. J Am Coll Cardiol 2000;36:1131-41.
    • (2000) J Am Coll Cardiol , vol.36 , pp. 1131-1141
    • Pibarot, P.1    Dumesnil, J.G.2
  • 3
    • 0033201582 scopus 로고    scopus 로고
    • Factors affecting left ventricular mass regression after aortic valve replacement with stentless valves
    • Del Rizzo DF, Abdoh A, Cartier P, Doty D, Westaby S. Factors affecting left ventricular mass regression after aortic valve replacement with stentless valves. Semin Thorac Cardiovasc Surg 1999;11(Suppl 1):114-20.
    • (1999) Semin Thorac Cardiovasc Surg , vol.11 , Issue.SUPPL. 1 , pp. 114-120
    • Del Rizzo, D.F.1    Abdoh, A.2    Cartier, P.3    Doty, D.4    Westaby, S.5
  • 4
    • 0034619384 scopus 로고    scopus 로고
    • Prosthesis-patient mismatch affects survival after aortic valve replacement
    • Rao V, Jamieson WR, Ivanov J, Armstrong S, David TE. Prosthesis-patient mismatch affects survival after aortic valve replacement. Circulation 2000;102(Suppl 3):5-9.
    • (2000) Circulation , vol.102 , Issue.SUPPL. 3 , pp. 5-9
    • Rao, V.1    Jamieson, W.R.2    Ivanov, J.3    Armstrong, S.4    David, T.E.5
  • 6
    • 0032990427 scopus 로고    scopus 로고
    • Influence of aortic valve replacement, prosthesis type, and size on functional outcome and ventricular mass in patients with aortic stenosis
    • Bech-Hanssen O, Caidahl K, Wall B, Myken P, Larsson S, Wallentin I. Influence of aortic valve replacement, prosthesis type, and size on functional outcome and ventricular mass in patients with aortic stenosis. J Thorac Cardiovasc Surg 1999;118:57-65.
    • (1999) J Thorac Cardiovasc Surg , vol.118 , pp. 57-65
    • Bech-Hanssen, O.1    Caidahl, K.2    Wall, B.3    Myken, P.4    Larsson, S.5    Wallentin, I.6
  • 7
    • 0029783402 scopus 로고    scopus 로고
    • Influence of the size of aortic valve prostheses on hemodynamics and change in left ventricular mass: Implications for the surgical management of aortic stenosis
    • Gonzalez-Juanatey JR, Garcia-Acuna JM, Vega Fernandez M, et al. Influence of the size of aortic valve prostheses on hemodynamics and change in left ventricular mass: Implications for the surgical management of aortic stenosis. J Thorac Cardiovasc Surg 1996;112:273-80.
    • (1996) J Thorac Cardiovasc Surg , vol.112 , pp. 273-280
    • Gonzalez-Juanatey, J.R.1    Garcia-Acuna, J.M.2    Vega Fernandez, M.3
  • 8
    • 0036481560 scopus 로고    scopus 로고
    • Recommendations for quantification of doppler echocardiography. A report from the Doppler Quantification Task Force of the Nomenclature and Standards Committee of the American Society of Echocardiography
    • Quinones MA, Otto CM, Stoddard M, Waggoner A, Zoghbi WA. Recommendations for quantification of doppler echocardiography. A report from the Doppler Quantification Task Force of the Nomenclature and Standards Committee of the American Society of Echocardiography. J Am Soc Echocardiogr 2002;15:167-84.
    • (2002) J Am Soc Echocardiogr , vol.15 , pp. 167-184
    • Quinones, M.A.1    Otto, C.M.2    Stoddard, M.3    Waggoner, A.4    Zoghbi, W.A.5
  • 9
    • 0022588019 scopus 로고
    • Echocardiographic assessment of left ventricular hypertrophy: Comparison to necropsy findings
    • Devereux RB, Alonso DR, Lutas EM, et al. Echocardiographic assessment of left ventricular hypertrophy: Comparison to necropsy findings. Am J Cardiol 1986;57:450-8.
    • (1986) Am J Cardiol , vol.57 , pp. 450-458
    • Devereux, R.B.1    Alonso, D.R.2    Lutas, E.M.3
  • 10
    • 0023758391 scopus 로고
    • Guidelines for reporting morbidity and mortality after cardiac valvular operations
    • Edmunds LH Jr, Cohn LH, Weisel RD. Guidelines for reporting morbidity and mortality after cardiac valvular operations. J Thorac Cardiovasc Surg 1988;96:351-3.
    • (1988) J Thorac Cardiovasc Surg , vol.96 , pp. 351-353
    • Edmunds L.H., Jr.1    Cohn, L.H.2    Weisel, R.D.3
  • 11
    • 0030932395 scopus 로고    scopus 로고
    • Nineteen-millimeter aortic St. Jude Medical heart valve prosthesis: Up to sixteen years' follow-up
    • Sawant D, Singh AK, Feng WC, Bert AA, Rotenberg F. Nineteen-millimeter aortic St. Jude Medical heart valve prosthesis: Up to sixteen years' follow-up. Ann Thorac Surg 1997;63:964-70.
    • (1997) Ann Thorac Surg , vol.63 , pp. 964-970
    • Sawant, D.1    Singh, A.K.2    Feng, W.C.3    Bert, A.A.4    Rotenberg, F.5
  • 12
    • 0032169403 scopus 로고    scopus 로고
    • Aortic valve replacement for octogenarians: Are small valves bad?
    • Medalion B, Lytle BW, McCarthy PM, et al. Aortic valve replacement for octogenarians: Are small valves bad? Ann Thorac Surg 1998;66:699-706.
    • (1998) Ann Thorac Surg , vol.66 , pp. 699-706
    • Medalion, B.1    Lytle, B.W.2    McCarthy, P.M.3
  • 13
    • 0032713685 scopus 로고    scopus 로고
    • Impact of small prosthetic valve size on operative mortality in elderly patients after aortic valve replacement for aortic stenosis: Does gender matter?
    • Adams DH, Chen RH, Kadner A, Aranki SF, Allred EN, Cohn LH. Impact of small prosthetic valve size on operative mortality in elderly patients after aortic valve replacement for aortic stenosis: Does gender matter? J Thorac Cardiovasc Surg 1999;118:815-22.
    • (1999) J Thorac Cardiovasc Surg , vol.118 , pp. 815-822
    • Adams, D.H.1    Chen, R.H.2    Kadner, A.3    Aranki, S.F.4    Allred, E.N.5    Cohn, L.H.6
  • 14
    • 0024393863 scopus 로고
    • A method of uniform stratification of risk for evaluating the results of surgery in acquired adult heart disease
    • Parsonnet V, Dean D, Bernstein AD. A method of uniform stratification of risk for evaluating the results of surgery in acquired adult heart disease. Circulation 1989;79:I3-12.
    • (1989) Circulation , vol.79
    • Parsonnet, V.1    Dean, D.2    Bernstein, A.D.3
  • 15
    • 0035117197 scopus 로고    scopus 로고
    • Effects of body size on operative, intermediate, and long-term outcomes after coronary artery bypass operation
    • Schwann TA, Habib RH, Zacharias A, et al. Effects of body size on operative, intermediate, and long-term outcomes after coronary artery bypass operation. Ann Thorac Surg 2001;71:521-31.
    • (2001) Ann Thorac Surg , vol.71 , pp. 521-531
    • Schwann, T.A.1    Habib, R.H.2    Zacharias, A.3
  • 16
    • 0035115632 scopus 로고    scopus 로고
    • Aortic valve replacement in geriatric patients: Determinants of in-hospital mortality
    • Bloomstein LZ, Gielchinsky I, Bernstein AD, et al. Aortic valve replacement in geriatric patients: Determinants of in-hospital mortality. Ann Thorac Surg 2001;71:597-600.
    • (2001) Ann Thorac Surg , vol.71 , pp. 597-600
    • Bloomstein, L.Z.1    Gielchinsky, I.2    Bernstein, A.D.3
  • 17
    • 0033203107 scopus 로고    scopus 로고
    • Left ventricular muscle mass regression after aortic valve replacement
    • Lee JW, Choi KJ, Lee SG, et al. Left ventricular muscle mass regression after aortic valve replacement. J Korean Med Sci 1999;14:511-9.
    • (1999) J Korean Med Sci , vol.14 , pp. 511-519
    • Lee, J.W.1    Choi, K.J.2    Lee, S.G.3
  • 18
    • 0012001177 scopus 로고    scopus 로고
    • Incomplete regression of hypertrophy following AVR is not influenced by valve size, nor patient-prosthesis mismatch
    • San Diego, California
    • Hanayama N, Mallidi H, Rao V, et al. Incomplete regression of hypertrophy following AVR is not influenced by valve size, nor patient-prosthesis mismatch. Presented at the Annual Meeting of the American Association for Thoracic Surgery, San Diego, California, 2001.
    • (2001) Annual Meeting of the American Association for Thoracic Surgery
    • Hanayama, N.1    Mallidi, H.2    Rao, V.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.