Comparison of the Cosmed K4 b2 and the Deltatrac II™ metabolic cart in measuring resting energy expenditure in adults

Author keywords

Cosmed; Deltatrac; REE; Resting energy expenditure

Indexed keywords

ADULT; ARTICLE; BASAL METABOLIC RATE; CALORIMETER; CLINICAL ARTICLE; CONTROLLED STUDY; ENERGY EXPENDITURE; FEMALE; HUMAN; INTERMETHOD COMPARISON; MALE; MEASUREMENT; PREDICTION AND FORECASTING; REFERENCE VALUE; RESPIRATORY QUOTIENT; STATISTICAL ANALYSIS; VALIDATION PROCESS; CALIBRATION; CALORIMETRY; COMPARATIVE STUDY; ENERGY METABOLISM; LUNG VENTILATION; METABOLISM; METHODOLOGY; OXYGEN CONSUMPTION; REPRODUCIBILITY; TELEMETRY; VALIDATION STUDY;

EID: 0036898278     PISSN: 02615614     EISSN: None     Source Type: Journal    
DOI: 10.1054/clnu.2002.0580     Document Type: Article
Times cited : (29)

References (23)
  • 1
    • 0029131263 scopus 로고
    • Stratification of injury severity using energy expenditure response in surgical infants
    • Chwals W J, Letton R W, Jamie A et al. Stratification of injury severity using energy expenditure response in surgical infants. J Pediatr Surg 1995; 30: 1161-1164
    • (1995) J. Pediatr. Surg. , vol.30 , pp. 1161-1164
    • Chwals, W.J.1    Letton, R.W.2    Jamie, A.3
  • 2
    • 0029901998 scopus 로고    scopus 로고
    • Measurement of oxygen consumption in disabled children by the Cosmed K2 portable telemetry system
    • Correy I S, Duffy C M, Cosgrave A P, Graham H K et al. Measurement of oxygen consumption in disabled children by the Cosmed K2 portable telemetry system. Dev Med Child Neurol 1996; 38(7): 585-593
    • (1996) Dev. Med. Child Neurol. , vol.38 , Issue.7 , pp. 585-593
    • Correy, I.S.1    Duffy, C.M.2    Cosgrave, A.P.3    Graham, H.K.4
  • 3
    • 0027615995 scopus 로고
    • Validity and reliability of the Cosmed K2 to measure oxygen uptake
    • Lothian F, Farrally M R, Mahoney C. Validity and reliability of the Cosmed K2 to measure oxygen uptake. Can J Appl Physiol 1993; 18(2): 197-206
    • (1993) Can. J. Appl. Physiol. , vol.18 , Issue.2 , pp. 197-206
    • Lothian, F.1    Farrally, M.R.2    Mahoney, C.3
  • 4
    • 0028017512 scopus 로고
    • A new equation to predict resting energy expenditure of surgical infants
    • Pierro A, Jones M O, Hammond P et al. A new equation to predict resting energy expenditure of surgical infants. J Pediatr Surg 1994; 8: 1103-1108
    • (1994) J. Pediatr. Surg. , vol.8 , pp. 1103-1108
    • Pierro, A.1    Jones, M.O.2    Hammond, P.3
  • 5
    • 0024603145 scopus 로고
    • Effect of propranolol on resting metabolic rate after severe head injury
    • Chiolero R, Breitenstein E, Thorin D. Effect of propranolol on resting metabolic rate after severe head injury. Crit Care Med 1989; 17: 328-332
    • (1989) Crit. Care Med. , vol.17 , pp. 328-332
    • Chiolero, R.1    Breitenstein, E.2    Thorin, D.3
  • 8
    • 0021776312 scopus 로고
    • Predicting basal metabolic rate, new standards and review of previous work
    • Schofield W. Predicting basal metabolic rate, new standards and review of previous work. Hum Nutr: Clin Nutr 1985; 39c(Suppl): 5-41
    • (1985) Hum. Nutr. Clin. Nutr. , vol.39 C , Issue.SUPPL. , pp. 5-41
    • Schofield, W.1
  • 9
    • 0003526098 scopus 로고
    • FAO/WHO/UNU. WHO Technical Report Series, Geneva: World Health Organisation
    • FAO/WHO/UNU. Energy and Protein Requirements. WHO Technical Report Series, Vol. 724. Geneva: World Health Organisation, 1985
    • (1985) Energy and Protein Requirements , vol.724
  • 10
    • 0025420169 scopus 로고
    • New methods for calculating metabolic rate with special reference to protein metabolism
    • Weir J B. New methods for calculating metabolic rate with special reference to protein metabolism. Nutrition 1949; 6(3): 213-221
    • (1949) Nutrition , vol.6 , Issue.3 , pp. 213-221
    • Weir, J.B.1
  • 11
    • 0028914731 scopus 로고
    • Clinical validation of the Deltatrac monitoring system in mechanically ventilated patients
    • Tissot S, Delafosse B, Bertrand O et al. Clinical validation of the Deltatrac monitoring system in mechanically ventilated patients. Inten Care Med 1995; 21: 149-153
    • (1995) Inten. Care Med. , vol.21 , pp. 149-153
    • Tissot, S.1    Delafosse, B.2    Bertrand, O.3
  • 12
    • 0025240910 scopus 로고
    • In vitro evaluation of a compact metabolic measurement instrument
    • Weissman C, Sardan A, Kemper M. In vitro evaluation of a compact metabolic measurement instrument. J Parenter Enteral Nutr 1990; 14(2): 216-221
    • (1990) J. Parenter. Enteral. Nutr. , vol.14 , Issue.2 , pp. 216-221
    • Weissman, C.1    Sardan, A.2    Kemper, M.3
  • 13
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • (8476)
    • Bland J M, Altman D G. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; 1(8476): 307-310
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 14
    • 0028012078 scopus 로고
    • Evaluation of the Cosmed K2 portable telemetric oxygen uptake analyzer
    • Crandall C G, Taylor S L, Raven P B. Evaluation of the Cosmed K2 portable telemetric oxygen uptake analyzer. Med Sci Sports Exerc 1994; 26(1): 108-111
    • (1994) Med. Sci. Sports Exerc. , vol.26 , Issue.1 , pp. 108-111
    • Crandall, C.G.1    Taylor, S.L.2    Raven, P.B.3
  • 17
    • 0027321105 scopus 로고
    • Mechanical efficiency of children with spastic cerebral palsy
    • Jones J, McLaughlin J F. Mechanical efficiency of children with spastic cerebral palsy. Dev Med Child Neurol 1993; 35(7): 614-620
    • (1993) Dev. Med. Child Neurol. , vol.35 , Issue.7 , pp. 614-620
    • Jones, J.1    McLaughlin, J.F.2
  • 18
    • 0029975860 scopus 로고    scopus 로고
    • Energy consumption in children with spina bifida and cerebral palsy: A comparative study
    • Duffy C M, Hill A E, Cosgrove A P, Correy I S, Graham H K. Energy consumption in children with spina bifida and cerebral palsy: a comparative study. Dev Med Child Neurol 1996; 38(3): 238-243
    • (1996) Dev. Med. Child Neurol. , vol.38 , Issue.3 , pp. 238-243
    • Duffy, C.M.1    Hill, A.E.2    Cosgrove, A.P.3    Correy, I.S.4    Graham, H.K.5
  • 19
    • 0030959089 scopus 로고    scopus 로고
    • Energy consumption in children with myelomeningocele: A comparison between reciprocating gait orthosis and hip-knee-ankle-foot orthosis ambulators
    • Cuddeford T J, Freeling R P, Thomas S S, Aiona M D, Rex D, Sirolli H, Elliott J, Magnusson M. Energy consumption in children with myelomeningocele: a comparison between reciprocating gait orthosis and hip-knee-ankle-foot orthosis ambulators. Dev Med Child Neurol 1997; 39(4): 239-242
    • (1997) Dev. Med. Child Neurol. , vol.39 , Issue.4 , pp. 239-242
    • Cuddeford, T.J.1    Freeling, R.P.2    Thomas, S.S.3    Aiona, M.D.4    Rex, D.5    Sirolli, H.6    Elliott, J.7    Magnusson, M.8
  • 20
    • 0030927347 scopus 로고    scopus 로고
    • The influence of flexed-knee gait on the energy cost of walking in children
    • Duffy C M, Hill A E, Graham H K. The influence of flexed-knee gait on the energy cost of walking in children. Dev Med Child Neurol 1997; 39(4): 234-238
    • (1997) Dev. Med. Child Neurol. , vol.39 , Issue.4 , pp. 234-238
    • Duffy, C.M.1    Hill, A.E.2    Graham, H.K.3
  • 21
    • 0029128946 scopus 로고
    • Evaluation of the Cosmed K2 telemetry system during exercise at moderate altitude
    • Bigard A X, Guezennec C Y. Evaluation of the Cosmed K2 telemetry system during exercise at moderate altitude. Med Sci Sports Exerc 1995; 27(9): 1333-1338
    • (1995) Med. Sci. Sports Exerc. , vol.27 , Issue.9 , pp. 1333-1338
    • Bigard, A.X.1    Guezennec, C.Y.2
  • 22
    • 0030880253 scopus 로고    scopus 로고
    • The Cosmed K4 telemetry system as an accurate device for oxygen uptake measurements during exercise
    • Hausswirth C, Bigard A X, Le Chevalier J M. The Cosmed K4 telemetry system as an accurate device for oxygen uptake measurements during exercise. Int J Sports Med 1997; 18(6): 449-453
    • (1997) Int. J. Sports Med. , vol.18 , Issue.6 , pp. 449-453
    • Hausswirth, C.1    Bigard, A.X.2    Le Chevalier, J.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.