-
2
-
-
10144256538
-
Dynamic MR digital subtraction angiography using contrast enhancement, fast data acquisition, and complex subtraction
-
Wang Y, Johnston DL, Breen JF, Huston J 3rd, Jack CR, Julsrud PR, Kiely MJ, King BF, Riederer SL, Ehman RL. Dynamic MR digital subtraction angiography using contrast enhancement, fast data acquisition, and complex subtraction. Magn Reson Med 1996;36:551-556.
-
(1996)
Magn Reson Med
, vol.36
, pp. 551-556
-
-
Wang, Y.1
Johnston, D.L.2
Breen, J.F.3
Huston J. III4
Jack, C.R.5
Julsrud, P.R.6
Kiely, M.J.7
King, B.F.8
Riederer, S.L.9
Ehman, R.L.10
-
4
-
-
0031029723
-
Time-resolved projection angiography after bolus injection of contrast agent
-
Hennig J, Schefler K, Laubenberger J, Strecker R. Time-resolved projection angiography after bolus injection of contrast agent. Magn Res Med 1997;37:341-345.
-
(1997)
Magn Res Med
, vol.37
, pp. 341-345
-
-
Hennig, J.1
Schefler, K.2
Laubenberger, J.3
Strecker, R.4
-
5
-
-
0031656172
-
3D time-resolved contrast-enhanced MR DSA: Advantages and tradeoffs
-
Mistretta CA, Grist TM, Korosec FR, Frayne R, Peters DC, Mazaheri Y, Carrol TJ. 3D time-resolved contrast-enhanced MR DSA: Advantages and tradeoffs. Magn Reson Med 199840:571-581.
-
(1998)
Magn Reson Med
, vol.40
, pp. 571-581
-
-
Mistretta, C.A.1
Grist, T.M.2
Korosec, F.R.3
Frayne, R.4
Peters, D.C.5
Mazaheri, Y.6
Carrol, T.J.7
-
6
-
-
0031771909
-
Comparison of two-dimensional MR digital subtraction angiography of the lower extremity with x-ray angiography
-
Winchester PA, Lee HM, Khilnani NM, Wang Y, Trost DW, Bush HL Jr, Sos TA. Comparison of two-dimensional MR digital subtraction angiography of the lower extremity with x-ray angiography. J Vasc Intervent Radiol 1998;9:891-900.
-
(1998)
J Vasc Intervent Radiol
, vol.9
, pp. 891-900
-
-
Winchester, P.A.1
Lee, H.M.2
Khilnani, N.M.3
Wang, Y.4
Trost, D.W.5
Bush H.L., Jr.6
Sos, T.A.7
-
7
-
-
0033255018
-
Dynamic contrast-enhanced subtraction MR angiography in intracranial vascular abnormalities
-
Takano K, Utsunomiya H, Ono H, Okazaki M, Tanaka A. Dynamic contrast-enhanced subtraction MR angiography in intracranial vascular abnormalities. Eur Radiol 1999;9:1909-1912.
-
(1999)
Eur Radiol
, vol.9
, pp. 1909-1912
-
-
Takano, K.1
Utsunomiya, H.2
Ono, H.3
Okazaki, M.4
Tanaka, A.5
-
8
-
-
0032864018
-
Abdominal aortic aneurysm. Detection of multilevel vascular pathology by time-resolved multiphase 3D gadolinium MR angiography: Initial report
-
Schoenberg SO, Wunsch C, Knopp MV, Essig M, Hawighorst H, Laub G, Prince MR, Allenberg JR, Van Kaick G. Abdominal aortic aneurysm. Detection of multilevel vascular pathology by time-resolved multiphase 3D gadolinium MR angiography: Initial report. Invest Radiol 199934:648-659.
-
(1999)
Invest Radiol
, vol.34
, pp. 648-659
-
-
Schoenberg, S.O.1
Wunsch, C.2
Knopp, M.V.3
Essig, M.4
Hawighorst, H.5
Laub, G.6
Prince, M.R.7
Allenberg, J.R.8
Van Kaick, G.9
-
9
-
-
0033999675
-
Time-resolved projection MRA: Clinical application in intracranial vascular malformations
-
Klisch J, Strecker R, Hennig J, Schumacher M. Time-resolved projection MRA: Clinical application in intracranial vascular malformations. Neuroradiology 2000;42:104-107.
-
(2000)
Neuroradiology
, vol.42
, pp. 104-107
-
-
Klisch, J.1
Strecker, R.2
Hennig, J.3
Schumacher, M.4
-
10
-
-
0034194351
-
Feasibility of using dynamic contrast-enhanced magnetic resonance angiography as the sole imaging modality prior to endovascular repair of abdominal aortic aneurysms
-
Ludman CN, Yusuf SW, Whitaker SC, Gregson RH, Walker S, Hopkinson BR. Feasibility of using dynamic contrast-enhanced magnetic resonance angiography as the sole imaging modality prior to endovascular repair of abdominal aortic aneurysms. Eur J Vasc Endovasc Surg 2000;19:524-530.
-
(2000)
Eur J Vasc Endovasc Surg
, vol.19
, pp. 524-530
-
-
Ludman, C.N.1
Yusuf, S.W.2
Whitaker, S.C.3
Gregson, R.H.4
Walker, S.5
Hopkinson, B.R.6
-
11
-
-
0034976061
-
Contrast-enhanced magnetic resonance angiography of the carotid bifurcation using the time-resolved imaging of contrast kinetics (TRICKS) technique
-
Turski PA, Korosec FR, Carroll TJ, Willig DS, Grist TM, Mistretta CA. Contrast-enhanced magnetic resonance angiography of the carotid bifurcation using the time-resolved imaging of contrast kinetics (TRICKS) technique. Top Magn Reson Imag 2001;12:175-181.
-
(2001)
Top Magn Reson Imag
, vol.12
, pp. 175-181
-
-
Turski, P.A.1
Korosec, F.R.2
Carroll, T.J.3
Willig, D.S.4
Grist, T.M.5
Mistretta, C.A.6
-
12
-
-
0035090141
-
Contrast enhanced peripheral MRA from abdominal aorta to pedal arteries: Combined dynamic 2D and bolus chase 3D acquisitions
-
Wang Y, Winchester PA, Khilnani NM, Lee HM, Watts R, Trost DW, Bush HL, Kent CK, Prince MR. Contrast enhanced peripheral MRA from abdominal aorta to pedal arteries: Combined dynamic 2D and bolus chase 3D acquisitions. Invest Radiol 2001;36:170-177.
-
(2001)
Invest Radiol
, vol.36
, pp. 170-177
-
-
Wang, Y.1
Winchester, P.A.2
Khilnani, N.M.3
Lee, H.M.4
Watts, R.5
Trost, D.W.6
Bush, H.L.7
Kent, C.K.8
Prince, M.R.9
-
13
-
-
0035109427
-
Pulmonary arteriovenous malformation: Characterization with time-resolved ultrafast: 3D MR angiography
-
Goyen M, Ruehm SG, Jagenburg A, Barkhausen J, Kroger K, Debatin JF. Pulmonary arteriovenous malformation: Characterization with time-resolved ultrafast: 3D MR angiography. J Magn Reson Imag 2001;13:458-460.
-
(2001)
J Magn Reson Imag
, vol.13
, pp. 458-460
-
-
Goyen, M.1
Ruehm, S.G.2
Jagenburg, A.3
Barkhausen, J.4
Kroger, K.5
Debatin, J.F.6
-
15
-
-
0019508593
-
A method for time domain filtering using computerized fluoroscopy
-
Kruger RA. A method for time domain filtering using computerized fluoroscopy. Med Phys 1981;8:466-470.
-
(1981)
Med Phys
, vol.8
, pp. 466-470
-
-
Kruger, R.A.1
-
16
-
-
0027381155
-
Generalized matched filtering for time-resolved MR angiography of pulsatile flow
-
Wang Y, Weber DM, Korosec FR, Mistretta CA, Grist TM, Swan JS, Turski PA. Generalized matched filtering for time-resolved MR angiography of pulsatile flow. Magn Reson Med 1993;30:600-608.
-
(1993)
Magn Reson Med
, vol.30
, pp. 600-608
-
-
Wang, Y.1
Weber, D.M.2
Korosec, F.R.3
Mistretta, C.A.4
Grist, T.M.5
Swan, J.S.6
Turski, P.A.7
-
17
-
-
0032867764
-
Venous signal suppression in 3D dynamic Gd-enhanced carotid artery imaging using the eigenimage filter
-
Kaandorp DW, Kopinga K, Wijn PF. Venous signal suppression in 3D dynamic Gd-enhanced carotid artery imaging using the eigenimage filter. Magn Reson Med 1999;42:307-313.
-
(1999)
Magn Reson Med
, vol.42
, pp. 307-313
-
-
Kaandorp, D.W.1
Kopinga, K.2
Wijn, P.F.3
-
18
-
-
0033979362
-
Fast functional MRA using time-resolved projection MR angiography with correlation analysis
-
Strecker R, Scheffler K, Klisch J, Lehnhardt S, Winterer J, Laubenberger J, Fischer H, Hennig J. Fast functional MRA using time-resolved projection MR angiography with correlation analysis. Magn Reson Med 2000;43:303-309.
-
(2000)
Magn Reson Med
, vol.43
, pp. 303-309
-
-
Strecker, R.1
Scheffler, K.2
Klisch, J.3
Lehnhardt, S.4
Winterer, J.5
Laubenberger, J.6
Fischer, H.7
Hennig, J.8
-
19
-
-
0034005783
-
Separation of arteries and veins in 3D MR angiography using correlation analysis
-
Bock M, Schoenberg SO, Floemer F, Schad LR. Separation of arteries and veins in 3D MR angiography using correlation analysis. Magn Reson Med 2000;43:481-487.
-
(2000)
Magn Reson Med
, vol.43
, pp. 481-487
-
-
Bock, M.1
Schoenberg, S.O.2
Floemer, F.3
Schad, L.R.4
-
20
-
-
0033976859
-
Free MRA of the abdomen: Postprocessing dynamic gadolinium-enhanced 3D axial MR images
-
Blasbalg R, Mitchell DG, Outwater EK, Ito K, Gabata T, Chiowanich P. Free MRA of the abdomen: Postprocessing dynamic gadolinium-enhanced 3D axial MR images. Abdom Imag 2000;25:62-66.
-
(2000)
Abdom Imag
, vol.25
, pp. 62-66
-
-
Blasbalg, R.1
Mitchell, D.G.2
Outwater, E.K.3
Ito, K.4
Gabata, T.5
Chiowanich, P.6
-
21
-
-
0011723076
-
Mask averaging to improve 2D projection MRA of peripheral arteries
-
Madison, WI
-
Prince MR, Yoo SK, Watts R, Kim J, Zabih R, Wang Y. Mask averaging to improve 2D projection MRA of peripheral arteries. In: Proceedings of the XIII Annual International Workshop on MRA, Madison, WI, 2001. p 84.
-
(2001)
Proceedings of the XIII Annual International Workshop on MRA
, pp. 84
-
-
Prince, M.R.1
Yoo, S.K.2
Watts, R.3
Kim, J.4
Zabih, R.5
Wang, Y.6
-
22
-
-
0004252445
-
-
Upper Saddle River, NJ: Prentice Hall
-
Zar JH. Biostatistical Analysis, 3rd Ed. Upper Saddle River, NJ: Prentice Hall; 1996. p 123-178.
-
(1996)
Biostatistical Analysis, 3rd Ed.
, pp. 123-178
-
-
Zar, J.H.1
-
23
-
-
0024453449
-
Adaptive technique for high-definition MR imaging of moving structures
-
Ehman RL, Felmlee JP. Adaptive technique for high-definition MR imaging of moving structures. Radiology 1989;173:255-263.
-
(1989)
Radiology
, vol.173
, pp. 255-263
-
-
Ehman, R.L.1
Felmlee, J.P.2
|