메뉴 건너뛰기




Volumn 16, Issue 3, 2002, Pages 283-287

A quasi-static method for determining the characteristics of a motion capture camera system in a "split-volume" configuration

Author keywords

Accuracy; Kinematics; Measurement; Repeatability; Resolution; Split volume

Indexed keywords

ACCURACY; ARTICLE; BODY MOVEMENT; CALIBRATION; CAMERA; DATA ANALYSIS; KINEMATICS; METHODOLOGY; PRIORITY JOURNAL;

EID: 0036890374     PISSN: 09666362     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0966-6362(02)00019-X     Document Type: Article
Times cited : (26)

References (9)
  • 1
    • 0025184578 scopus 로고
    • Assessing and reporting the accuracy of position measurements made with optical tracking systems
    • Haggard P., Wing A.M. Assessing and reporting the accuracy of position measurements made with optical tracking systems. J. Motor Behav. 22:(1):1990;315-321.
    • (1990) J. Motor Behav. , vol.22 , Issue.1 , pp. 315-321
    • Haggard, P.1    Wing, A.M.2
  • 2
    • 0028812129 scopus 로고
    • Accuracy of three-dimensional linear and angular estimates obtained with the Ariel performance analysis system
    • Klein P.J., DeHaven J.J. Accuracy of three-dimensional linear and angular estimates obtained with the Ariel performance analysis system. Arch. Phys. Med. Rehab. 76:1995;183-189.
    • (1995) Arch. Phys. Med. Rehab. , vol.76 , pp. 183-189
    • Klein, P.J.1    DeHaven, J.J.2
  • 3
    • 0032168922 scopus 로고    scopus 로고
    • Some effects of camera placement on the accuracy of the Kinemetrix three-dimensional motion analysis system
    • Thornton M.J., Morrissey M.C., Coutts F.J. Some effects of camera placement on the accuracy of the Kinemetrix three-dimensional motion analysis system. Clin. Biomech. 13:1998;452-454.
    • (1998) Clin. Biomech. , vol.13 , pp. 452-454
    • Thornton, M.J.1    Morrissey, M.C.2    Coutts, F.J.3
  • 4
    • 0026508375 scopus 로고
    • Reproducibility and accuracy of angle measurements obtained under static conditions with the motion analysis video system
    • Vander Linden D.W., Carlson S.J., Hubbard R.L. Reproducibility and accuracy of angle measurements obtained under static conditions with the motion analysis video system. Phys. Ther. 72:1992;300-305.
    • (1992) Phys. Ther. , vol.72 , pp. 300-305
    • Vander Linden, D.W.1    Carlson, S.J.2    Hubbard, R.L.3
  • 5
    • 0031453551 scopus 로고    scopus 로고
    • Accuracy of reconstructed angular estimates obtained with the Ariel performance analysis system
    • Wilson D.J., Smith B.K., Gibson J.K. Accuracy of reconstructed angular estimates obtained with the Ariel performance analysis system. Phys. Ther. 77:1997;1741-1746.
    • (1997) Phys. Ther. , vol.77 , pp. 1741-1746
    • Wilson, D.J.1    Smith, B.K.2    Gibson, J.K.3
  • 6
    • 0032871313 scopus 로고    scopus 로고
    • Measuring small linear displacements with a three-dimensional video motion analysis system: Determining its accuracy and precision
    • Everaert D.G., Spaepen A.J., Wouters M.J., Stappaerts K.H., Oostendorp R.A.B. Measuring small linear displacements with a three-dimensional video motion analysis system: Determining its accuracy and precision. Arch. Phys. Med. Rehab. 80:1999;1082-1089.
    • (1999) Arch. Phys. Med. Rehab. , vol.80 , pp. 1082-1089
    • Everaert, D.G.1    Spaepen, A.J.2    Wouters, M.J.3    Stappaerts, K.H.4    Oostendorp, R.A.B.5
  • 8
    • 0001746929 scopus 로고    scopus 로고
    • The measurement of human motion: A comparison of commercially available systems
    • Richards J.G. The measurement of human motion: A comparison of commercially available systems. Human Movement Sci. 18:1999;589-602.
    • (1999) Human Movement Sci. , vol.18 , pp. 589-602
    • Richards, J.G.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.