메뉴 건너뛰기




Volumn 3, Issue 4, 2002, Pages 287-297

Quantitative assessment of harmonic power Doppler myocardial perfusion imaging with intravenous Levovist™ in patients with myocardial infarction: Comparison with myocardial viability evaluated by thallium-201 single-photon emission computed tomography and coronary flow reserve

Author keywords

Contrast media; Echocardiography; Hyperaemia; Microcirculation; Stress

Indexed keywords

ADENOSINE; SHU 508; THALLIUM 201;

EID: 0036889036     PISSN: 15252167     EISSN: None     Source Type: Journal    
DOI: 10.1053/euje.2002.0178     Document Type: Article
Times cited : (7)

References (22)
  • 1
    • 0029022557 scopus 로고
    • Prediction of improvement of regional left ventricular function after surgical revascularization. A comparison of low-dose dobutamine echocardiography with 201Tl single-photon emission computed tomography
    • Arnese M, Cornel JH, Salustri A et al. Prediction of improvement of regional left ventricular function after surgical revascularization. A comparison of low-dose dobutamine echocardiography with 201Tl single-photon emission computed tomography. Circulation 1995; 91: 2748-252.
    • (1995) Circulation , vol.91 , pp. 2748-3252
    • Arnese, M.1    Cornel, J.H.2    Salustri, A.3
  • 2
    • 0342483929 scopus 로고    scopus 로고
    • Prediction of recovery of myocardial dysfunction after revascularization. Comparison of fluorine- 18-fluorodeoxyglucose/thallium- 201SPECT, thallium-201 stress-reinjection SPECT and dobutamine echocardiography
    • Bax JJ, Cornel JH, Visser FC et al. Prediction of recovery of myocardial dysfunction after revascularization. Comparison of fluorine- 18-fluorodeoxyglucose/thallium- 201SPECT, thallium-201 stress-reinjection SPECT and dobutamine echocardiography. J Am Coll Cardiol 1996; 28: 558-564.
    • (1996) J. Am. Coll. Cardiol , vol.28 , pp. 558-564
    • Bax, J.J.1    Cornel, J.H.2    Visser, F.C.3
  • 3
    • 0026504959 scopus 로고
    • Validation of a Doppler guide wire for intravascular measurement of coronary artery flow velocity
    • Doucette JW, Corl PD, Payne HM et al. Validation of a Doppler guide wire for intravascular measurement of coronary artery flow velocity. Circulation 1992; 85: 1899-1911.
    • (1992) Circulation , vol.85 , pp. 1899-1911
    • Doucette, J.W.1    Corl, P.D.2    Payne, H.M.3
  • 4
    • 0030880821 scopus 로고    scopus 로고
    • Retinopathy identifies marked restriction of coronary flow reserve in patients with diabetes mellitus
    • Akasaka T, Yoshida K, Hozumi T et al. Retinopathy identifies marked restriction of coronary flow reserve in patients with diabetes mellitus. J Am Coll Cardiol 1997; 30: 935-941.
    • (1997) J. Am. Coll. Cardiol , vol.30 , pp. 935-941
    • Akasaka, T.1    Yoshida, K.2    Hozumi, T.3
  • 5
    • 0033002339 scopus 로고    scopus 로고
    • Coronary blood flow reserve and wall motion recovery in patients undergoing angioplasty for myocardial infarction
    • Teiger E, Garot J, Aptecar P et al. Coronary blood flow reserve and wall motion recovery in patients undergoing angioplasty for myocardial infarction. Eur Heart J 1999; 20: 285-292.
    • (1999) Eur Heart J , vol.20 , pp. 285-292
    • Teiger, E.1    Garot, J.2    Aptecar, P.3
  • 6
    • 0033765478 scopus 로고    scopus 로고
    • Coronary flow reserve is reflective of myocardial perfusion status in acute anterior myocardial infarction
    • Lim DS, Kim YH, Lee HS et al. Coronary flow reserve is reflective of myocardial perfusion status in acute anterior myocardial infarction. Cathet Cardiovasc Intervent 2000; 51: 281-286.
    • (2000) Cathet. Cardiovasc. Intervent , vol.51 , pp. 281-286
    • Lim, D.S.1    Kim, Y.H.2    Lee, H.S.3
  • 7
    • 0026533530 scopus 로고
    • Relation of perfusion defects observed with myocardial contrast echocardiography to the severity of coronary stenosis: Correlation with thallium-201 single-photon emission tomography
    • Cheirif J, Desir RM, Bolli R et al. Relation of perfusion defects observed with myocardial contrast echocardiography to the severity of coronary stenosis: correlation with thallium-201 single-photon emission tomography. J Am Coll Cardiol 1992; 19: 1343-1349.
    • (1992) J. Am. Coll. Cardiol , vol.19 , pp. 1343-1349
    • Cheirif, J.1    Desir, R.M.2    Bolli, R.3
  • 8
    • 0028798756 scopus 로고
    • Temporal changes in myocardial perfusion patterns in patients with reperfused anterior wall myocardial infarction. Their relation to myocardial viability
    • Ito H, Iwakura K, Oh H et al. Temporal changes in myocardial perfusion patterns in patients with reperfused anterior wall myocardial infarction. Their relation to myocardial viability. Circulation 1995; 91: 656-662.
    • (1995) Circulation , vol.91 , pp. 656-662
    • Ito, H.1    Iwakura, K.2    Oh, H.3
  • 9
    • 0028272464 scopus 로고
    • Microvascular integrity indicates myocellular viability in patients with recent myocardial infarction. New insights using myocardial contrast echocardiography
    • Ragosta M, Camarano G, Kaul S, Powers ER, Sarembock IJ, Gimple LW. Microvascular integrity indicates myocellular viability in patients with recent myocardial infarction. New insights using myocardial contrast echocardiography. Circulation 1994; 89: 2562-2569.
    • (1994) Circulation , vol.89 , pp. 2562-2569
    • Ragosta, M.1    Camarano, G.2    Kaul, S.3    Powers, E.R.4    Sarembock, I.J.5    Gimple, L.W.6
  • 10
    • 0032212242 scopus 로고    scopus 로고
    • Accuracy and feasibility of contrast echocardiography for detection of perfusion defects in routine practice: Comparison with wall motion and technetium-99m sestamibi single-photon emission computed tomography
    • Marwick TH, Brunken R, Meland N et al. Accuracy and feasibility of contrast echocardiography for detection of perfusion defects in routine practice: comparison with wall motion and technetium-99m sestamibi single-photon emission computed tomography. J Am Coll Cardiol 1998; 32: 1260-1269.
    • (1998) J. Am. Coll. Cardiol , vol.32 , pp. 1260-1269
    • Marwick, T.H.1    Brunken, R.2    Meland, N.3
  • 11
    • 0033952843 scopus 로고    scopus 로고
    • Power Doppler harmonic imaging: A feasibility study of a new technique for the assessment of myocardial perfusion
    • Senior R, Kaul S, Soman P, Lahiri A. Power Doppler harmonic imaging: A feasibility study of a new technique for the assessment of myocardial perfusion. Am Heart J 2000; 139: 245-251.
    • (2000) Am Heart J , vol.139 , pp. 245-251
    • Senior, R.1    Kaul, S.2    Soman, P.3    Lahiri, A.4
  • 12
    • 0034604241 scopus 로고    scopus 로고
    • Assessment of myocardial perfusion by harmonic power Doppler at rest and during adenosine stress. Comparison with 99mTc-Sestamibi SPECT imaging
    • Heinle SK, Noblin J, Goree-Best P et al. Assessment of myocardial perfusion by harmonic power Doppler at rest and during adenosine stress. Comparison with 99mTc-Sestamibi SPECT imaging. Circulation 2000; 102: 55-60.
    • (2000) Circulation , vol.102 , pp. 55-60
    • Heinle, S.K.1    Noblin, J.2    Goree-Best, P.3
  • 13
    • 0026726435 scopus 로고
    • Comparison of coronary responses to intracoronary and intraaortic ergonovine and isosorbide dinitrate in patients with atypical chest pain
    • Hoshio A, Shirota K, Sawada Y et al. Comparison of coronary responses to intracoronary and intraaortic ergonovine and isosorbide dinitrate in patients with atypical chest pain, Am J Cardiol 1992; 70: 1007-1009.
    • (1992) Am. J. Cardiol , vol.70 , pp. 1007-1009
    • Hoshio, A.1    Shirota, K.2    Sawada, Y.3
  • 14
    • 0030943213 scopus 로고    scopus 로고
    • Stimulated acoustic emission nonbackscatter contrast effect of microbubbles seen with harmonic power Doppler imaging
    • Tiemann K, Becher H, Bimmel D, Schlief R, Nanda NC. Stimulated acoustic emission nonbackscatter contrast effect of microbubbles seen with harmonic power Doppler imaging. Echocardiography 1997; 14: 65-70.
    • (1997) Echocardiography , vol.14 , pp. 65-70
    • Tiemann, K.1    Becher, H.2    Bimmel, D.3    Schlief, R.4    Nanda, N.C.5
  • 16
    • 0033035902 scopus 로고    scopus 로고
    • Potential advantage of flash echocardiography for digital subtraction of B-mode images acquired during myocardial contrast echocardiography
    • Pelberg RA, Wei K, Kamiyama N, Sklenar J, Bin J, Kaul S. Potential advantage of flash echocardiography for digital subtraction of B-mode images acquired during myocardial contrast echocardiography. J Am Soc Echocardiogr 1999; 12: 85-93.
    • (1999) J. Am. Soc. Echocardiogr , vol.12 , pp. 85-93
    • Pelberg, R.A.1    Wei, K.2    Kamiyama, N.3    Sklenar, J.4    Bin, J.5    Kaul, S.6
  • 18
    • 0029079905 scopus 로고
    • Fractional moving blood volume: Estimation with power Doppler US
    • Rubin JM, Adler RS, Fowlkes JB et al. Fractional moving blood volume: estimation with power Doppler US. Radiology 1995; 197: 183-190.
    • (1995) Radiology , vol.197 , pp. 183-190
    • Rubin, J.M.1    Adler, R.S.2    Fowlkes, J.B.3
  • 21
    • 18844474104 scopus 로고    scopus 로고
    • Assessment of myocardial reperfusion by intravenous myocardial contrast echocardiography and coronary flow reserve after primary percutaneous transluminal coronary angiography in patients with acute myocardial infarction
    • Lepper W, Hoffmann R, Kamp O et al. Assessment of myocardial reperfusion by intravenous myocardial contrast echocardiography and coronary flow reserve after primary percutaneous transluminal coronary angiography in patients with acute myocardial infarction. Circulation 2000; 101: 2368-2374.
    • (2000) Circulation , vol.101 , pp. 2368-2374
    • Lepper, W.1    Hoffmann, R.2    Kamp, O.3
  • 22
    • 0034973421 scopus 로고    scopus 로고
    • Intravenous myocardial contrast echocardiography predicts recovery of dyssynergic myocardium early after acute myocardial infarction
    • Swinburn JM, Lahiri A, Senior R. Intravenous myocardial contrast echocardiography predicts recovery of dyssynergic myocardium early after acute myocardial infarction. J Am Coll Cardiol 2001; 38: 19-25.
    • (2001) J. Am. Coll. Cardiol , vol.38 , pp. 19-25
    • Swinburn, J.M.1    Lahiri, A.2    Senior, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.