메뉴 건너뛰기




Volumn 57, Issue 6, 2002, Pages 825-830

Accuracy of the convolution/superposition dose calculation algorithm at the condition of electron disequilibrium

Author keywords

Convolution superposition algorithm; DOSXYZ; Electron disequilibrium; Monte Carlo simulation; OMEGA BEAM; Percent depth dose curve

Indexed keywords

ALGORITHMS; DOSIMETRY; MONTE CARLO METHODS;

EID: 0036888482     PISSN: 09698043     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0969-8043(02)00228-2     Document Type: Article
Times cited : (11)

References (11)
  • 1
    • 0023280868 scopus 로고
    • Calculation and application of point spread functions for treatment planning with high energy photon beams
    • Ahnesjo A., Andreo P., Brahme A. Calculation and application of point spread functions for treatment planning with high energy photon beams. Acta Oncol. 26:1987;49-51.
    • (1987) Acta Oncol. , vol.26 , pp. 49-51
    • Ahnesjo, A.1    Andreo, P.2    Brahme, A.3
  • 2
    • 0023138959 scopus 로고
    • Presta: The parameter reduced electron step transport algorithm for electron Monte Carlo transport
    • Bielajew A.E., Rogers D.W.O. Presta. the parameter reduced electron step transport algorithm for electron Monte Carlo transport Nucl. Instrum. Method Phys. Res. B. 18:1987;165-181.
    • (1987) Nucl. Instrum. Method Phys. Res. B , vol.18 , pp. 165-181
    • Bielajew, A.E.1    Rogers, D.W.O.2
  • 5
    • 0034772905 scopus 로고    scopus 로고
    • Monte Carlo simulation of clinical linear accelerator
    • Lin S.Y., Chu T.C., Lin J.P. Monte Carlo simulation of clinical linear accelerator. Appl. Radiat. Isotopes. 55:2001;759-765.
    • (2001) Appl. Radiat. Isotopes , vol.55 , pp. 759-765
    • Lin, S.Y.1    Chu, T.C.2    Lin, J.P.3
  • 6
    • 0021907462 scopus 로고
    • A convolution method of calculating dose for 15-MV X-rays
    • Mackie T.R., Scrimger J.W., Battista J.J. A convolution method of calculating dose for 15-MV X-rays. Med. Phys. 12:1984;188-196.
    • (1984) Med. Phys. , vol.12 , pp. 188-196
    • Mackie, T.R.1    Scrimger, J.W.2    Battista, J.J.3
  • 8
    • 0008796868 scopus 로고    scopus 로고
    • Radiochromic film dosimetry: Recommendation of AAPM Radiation Therapy Committee Task Group 55
    • Niroomand-Rad A.et al. Radiochromic film dosimetry. Recommendation of AAPM Radiation Therapy Committee Task Group 55 Med. Phys. 25:1998;2093-2115.
    • (1998) Med. Phys. , vol.25 , pp. 2093-2115
    • Niroomand-Rad, A.1
  • 10
    • 0032978977 scopus 로고    scopus 로고
    • Experimental evaluation of interface doses in the presence of air cavities compared with treatment planning algorithm
    • Shahine B.H., Al-Ghazi M.S.A.L., El-Khatib E. Experimental evaluation of interface doses in the presence of air cavities compared with treatment planning algorithm. Med. Phys. 26:1999;350-355.
    • (1999) Med. Phys. , vol.26 , pp. 350-355
    • Shahine, B.H.1    Al-Ghazi, M.S.A.L.2    El-Khatib, E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.