메뉴 건너뛰기




Volumn 49, Issue 12, 2002, Pages 1665-1685

Approach to 3-D ultrasound high resolution imaging for mechanically moving large-aperture transducer based upon Fourier transform

Author keywords

[No Author keywords available]

Indexed keywords

APPROXIMATION THEORY; BANDWIDTH; COMPUTER SIMULATION; FAST FOURIER TRANSFORMS; OPTICAL RESOLVING POWER; PATTERN RECOGNITION SYSTEMS; TRANSCEIVERS; TRANSDUCERS; ULTRASONIC TRANSMISSION; WAVE EQUATIONS;

EID: 0036883374     PISSN: 08853010     EISSN: None     Source Type: Journal    
DOI: 10.1109/TUFFC.2002.1159846     Document Type: Article
Times cited : (11)

References (19)
  • 1
    • 0002227446 scopus 로고
    • 3D ultrasound - The kretztechnic voluson® approach
    • D. Kirbach and T. A. Whitlingham, "3D Ultrasound-the Kretztechnic Voluson® approach," Eur. J. Ultrasound, vol. 1, pp. 85-89, 1994.
    • (1994) Eur. J. Ultrasound , vol.1 , pp. 85-89
    • Kirbach, D.1    Whitlingham, T.A.2
  • 2
    • 0032423607 scopus 로고    scopus 로고
    • Three-dimensional ultrasound imaging
    • T. R. Nelson and D. H. Pretorius, "Three-dimensional ultrasound imaging," Ultrasound Med. Biol., vol. 24, no. 9, pp. 1243-1270, 1998.
    • (1998) Ultrasound Med. Biol. , vol.24 , Issue.9 , pp. 1243-1270
    • Nelson, T.R.1    Pretorius, D.H.2
  • 3
    • 0032971037 scopus 로고    scopus 로고
    • Dynamic three-dimensional freehand echocardiography using raw digital ultrasound data
    • S. Berg, H. Torp, D. Martens, E. Steen, S. Samstad, I. Hoivik, and B. Olstad, "Dynamic three-dimensional freehand echocardiography using raw digital ultrasound data," Ultrasound Med. Biol., vol. 25, no. 5, pp. 745-753, 1999.
    • (1999) Ultrasound Med. Biol. , vol.25 , Issue.5 , pp. 745-753
    • Berg, S.1    Torp, H.2    Martens, D.3    Steen, E.4    Samstad, S.5    Hoivik, I.6    Olstad, B.7
  • 5
    • 0019287643 scopus 로고
    • A real-time synthetic aperture imaging system
    • P. O. Corel and C. S. Kino, "A real-time synthetic aperture imaging system," Acoust. Imaging, vol. 9, pp. 341-355, 1970.
    • (1970) Acoust. Imaging , vol.9 , pp. 341-355
    • Corel, P.O.1    Kino, C.S.2
  • 6
    • 0030196861 scopus 로고    scopus 로고
    • A 100 MHz ultrasound imaging system for dermatologic and ophthalmologic diagnostics
    • July
    • C. Passmann and H. Ermert, "A 100 MHz ultrasound imaging system for dermatologic and ophthalmologic diagnostics," IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. 43, pp. 545-552, July 1996.
    • (1996) IEEE Trans. Ultrason., Ferroelect., Freq. Contr. , vol.43 , pp. 545-552
    • Passmann, C.1    Ermert, H.2
  • 9
    • 0013234579 scopus 로고    scopus 로고
    • A new approach to obtain non-diffraction beam with near-field resolution on linear and convex arrays
    • Z. M. Benenson, N. S. Kulberg, and T. T. Kasumov, "A new approach to obtain non-diffraction beam with near-field resolution on linear and convex arrays," Acoust. Imaging, vol. 23, pp. 303-308, 1997.
    • (1997) Acoust. Imaging , vol.23 , pp. 303-308
    • Benenson, Z.M.1    Kulberg, N.S.2    Kasumov, T.T.3
  • 10
    • 0026053874 scopus 로고
    • A model for the propagation and scattering of ultrasound in tissue
    • J. A. Jensen, "A model for the propagation and scattering of ultrasound in tissue," J. Acoust. Soc. Amer., vol. 89, pp. 188-191, 1991.
    • (1991) J. Acoust. Soc. Amer. , vol.89 , pp. 188-191
    • Jensen, J.A.1
  • 13
  • 14
    • 0031187849 scopus 로고    scopus 로고
    • 2D and 3D high frame imaging with limited diffraction beams
    • July
    • J.-Y. Lu, "2D and 3D high frame imaging with limited diffraction beams," IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. 44, no. 4, pp. 839-856, July 1997.
    • (1997) IEEE Trans. Ultrason., Ferroelect., Freq. Contr. , vol.44 , Issue.4 , pp. 839-856
    • Lu, J.-Y.1
  • 15
    • 0026128882 scopus 로고
    • High-speed ultrasound volumetric imaging system. Part I: Transducer design and beem steering
    • Mar.
    • S. W. Smith, H. C. Pavy, Jr., and O. T. von Ramm, "High-speed ultrasound volumetric imaging system. Part I: Transducer design and beem steering," IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. 38, pp. 100-108, Mar. 1991.
    • (1991) IEEE Trans. Ultrason., Ferroelect., Freq. Contr. , vol.38 , pp. 100-108
    • Smith, S.W.1    Pavy H.C., Jr.2    Von Ramm, O.T.3
  • 16
    • 0026128878 scopus 로고
    • High-speed ultrasound volumetric imaging system. Part II: Parallel processing and image display
    • Mar.
    • O. T. von Ramm, S. W. Smith, and H. C. Revy, Jr., "High-speed ultrasound volumetric imaging system. Part II: Parallel processing and image display," IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. 38, pp. 109-115, Mar. 1991.
    • (1991) IEEE Trans. Ultrason., Ferroelect., Freq. Contr. , vol.38 , pp. 109-115
    • Von Ramm, O.T.1    Smith, S.W.2    Revy H.C., Jr.3
  • 17
    • 0027849529 scopus 로고
    • Sparse geometry for two-dimensional array transducers in volumetric imaging
    • R. E. Davidsen and S. W. Smith, "Sparse geometry for two-dimensional array transducers in volumetric imaging," in Proc. IEEE Ultrason. Symp., 1993, pp. 1091-1094.
    • (1993) Proc. IEEE Ultrason. Symp. , pp. 1091-1094
    • Davidsen, R.E.1    Smith, S.W.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.