메뉴 건너뛰기




Volumn 22, Issue 17, 2002, Pages 1905-1918

Experimental investigation on the feasibility of a movable heat-insulation device

Author keywords

Boiler; Combustion; Experimental investigation; Movable heat insulation device

Indexed keywords

CALORIFIC VALUE; COMBUSTION; GAS FIRED BOILERS; GAS FURNACES; PROBLEM SOLVING; STEAM;

EID: 0036882497     PISSN: 13594311     EISSN: None     Source Type: Journal    
DOI: 10.1016/S1359-4311(02)00114-X     Document Type: Article
Times cited : (10)

References (13)
  • 2
    • 0001476894 scopus 로고    scopus 로고
    • On the prediction of pulverized coal flame stability
    • Lockwood F.C., Mahmud T. On the prediction of pulverized coal flame stability. Combust. Sci. Tech. 66(3):1999;319-329.
    • (1999) Combust. Sci. Tech. , vol.66 , Issue.3 , pp. 319-329
    • Lockwood, F.C.1    Mahmud, T.2
  • 4
    • 84953487025 scopus 로고    scopus 로고
    • Stability limits of pulverized coal burners
    • Godoy S. Stability limits of pulverized coal burners. Combust. Sci. Tech. 44(5):1996;319-335.
    • (1996) Combust. Sci. Tech. , vol.44 , Issue.5 , pp. 319-335
    • Godoy, S.1
  • 5
    • 0002754475 scopus 로고
    • Simulation study on dynamic analysis of stability of tangentially combustion process - Part II, results and analysis
    • Huaichun Z. Simulation study on dynamic analysis of stability of tangentially combustion process - part II, results and analysis. Proc. Chinese Soc. Electr. Eng. 11(2):1994;32-37.
    • (1994) Proc. Chinese Soc. Electr. Eng. , vol.11 , Issue.2 , pp. 32-37
    • Huaichun, Z.1
  • 6
    • 0003042846 scopus 로고
    • International flame research foundation: The effect of fineness and recirculation on the combustion of low-volatile pulverized coal - A report of the trials P.TOC.IV
    • Dipl.-Ing., Ph.D.
    • Beer J.M. Dipl.-Ing., Ph.D., International flame research foundation: The effect of fineness and recirculation on the combustion of low-volatile pulverized coal - A report of the trials P.TOC.IV. Fuel. 37:1964;286-313.
    • (1964) Fuel , vol.37 , pp. 286-313
    • Beer, J.M.1
  • 7
    • 0002759380 scopus 로고
    • Recirculation and its effects in combustion systems
    • Ph.D., ARIC, M.Inst.F.
    • Hedley A.B. Ph.D., ARIC, M.Inst.F., Recirculation and its effects in combustion systems. J. Inst. Fuel. 1961;290-297.
    • (1961) J. Inst. Fuel , pp. 290-297
    • Hedley, A.B.1
  • 8
    • 0035485583 scopus 로고    scopus 로고
    • Numerical simulation of influence of refractory faced zones on temperature field in pulverized coal boiler
    • Gong G.-c., Mei Z., Huang S.-f. Numerical simulation of influence of refractory faced zones on temperature field in pulverized coal boiler. Power Eng. 21(5):2001;1405-1411.
    • (2001) Power Eng. , vol.21 , Issue.5 , pp. 1405-1411
    • Gong, G.-C.1    Mei, Z.2    Huang, S.-F.3
  • 9
    • 0025893481 scopus 로고    scopus 로고
    • Effect of refractory emittance in industrial furnace
    • C.L. DeBellis, Effect of refractory emittance in industrial furnace, ASME1991, HTD-vol. 160, pp. 105-114.
    • ASME1991 , vol.HTD-160 , pp. 105-114
    • DeBellis, C.L.1
  • 10
    • 0035485902 scopus 로고    scopus 로고
    • Improve combustion efficiency of coal-fired boiler at low load using movable heat-insulation layer
    • Lin C.D., Zhong Y.X., Liang L. Improve combustion efficiency of coal-fired boiler at low load using movable heat-insulation layer. Power Eng. 21(5):2001;1390-1395.
    • (2001) Power Eng. , vol.21 , Issue.5 , pp. 1390-1395
    • Lin, C.D.1    Zhong, Y.X.2    Liang, L.3
  • 12
    • 0035510371 scopus 로고    scopus 로고
    • Design of movable heat-insulation layer for a coal fired boiler
    • in Chinese
    • Lin C.D., Jun Y.J., Guang Z.C. Design of movable heat-insulation layer for a coal fired boiler. J. Huazhong University Sci. Technol. 29(11):2001;101-103. (in Chinese).
    • (2001) J. Huazhong University Sci. Technol. , vol.29 , Issue.11 , pp. 101-103
    • Lin, C.D.1    Jun, Y.J.2    Guang, Z.C.3
  • 13
    • 0002166887 scopus 로고    scopus 로고
    • Quasi-constant temperature combustion based on movable heat-insulation layer and its influence on pulverized-coal fired boiler performance
    • in Chinese
    • Donglin Chen, Chuguang Zheng Quasi-constant temperature combustion based on movable heat-insulation layer and its influence on pulverized-coal fired boiler performance. Power Sys. Eng. 18(1):2002;1-6. (in Chinese).
    • (2002) Power Sys. Eng. , vol.18 , Issue.1 , pp. 1-6
    • Chen, D.1    Zheng, C.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.