메뉴 건너뛰기




Volumn 36, Issue 6, 2002, Pages 447-455

Noninvasive measurement of shear rate in autologous and prosthetic bypass grafts

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGE; AGED; ARTERY BLOOD FLOW; ARTICLE; BLOOD FLOW VELOCITY; BLOOD VESSEL PROSTHESIS; BYPASS SURGERY; CLINICAL ARTICLE; COLOR ULTRASOUND FLOWMETRY; COMPUTER PROGRAM; CONTROLLED STUDY; CORONARY ARTERY DISEASE; DIABETES MELLITUS; DIAGNOSTIC TEST; FEMALE; HUMAN; HYPERCHOLESTEROLEMIA; HYPERTENSION; ISCHEMIA; M MODE ECHOCARDIOGRAPHY; MALE; MATHEMATICAL ANALYSIS; MATHEMATICAL MODEL; SEX DIFFERENCE; SHEAR RATE; SMOKING; STATISTICAL ANALYSIS; THROMBOGENESIS; THROMBOGENICITY; VEIN GRAFT;

EID: 0036862299     PISSN: 15385744     EISSN: None     Source Type: Journal    
DOI: 10.1177/153857440203600605     Document Type: Article
Times cited : (6)

References (30)
  • 1
    • 0028314932 scopus 로고
    • Autogenous venous bypass grafts - Still the standard
    • DeWeese JA: Autogenous venous bypass grafts - Still the standard. Cardiovasc Surg 2:180-186, 1994
    • (1994) Cardiovasc Surg , vol.2 , pp. 180-186
    • DeWeese, J.A.1
  • 2
    • 0021679132 scopus 로고
    • Polytetrafluoroethylene grafts as the first-choice arterial substitute in femoropopliteal revascularization
    • Quinones-Baldrich WJ, Martin-Paredero V, Baker JD, et al: Polytetrafluoroethylene grafts as the first-choice arterial substitute in femoropopliteal revascularization. Arch Surg 119:1238-1243, 1984
    • (1984) Arch Surg , vol.119 , pp. 1238-1243
    • Quinones-Baldrich, W.J.1    Martin-Paredero, V.2    Baker, J.D.3
  • 4
    • 0022645576 scopus 로고
    • Six-year prospective multicenter randomized comparison of autologous saphenous vein and expanded polytetrafluoroethylene grafts in infrainguinal arterial reconstructions
    • Veith FJ, Gupta SK, Ascer E, et al: Six-year prospective multicenter randomized comparison of autologous saphenous vein and expanded polytetrafluoroethylene grafts in infrainguinal arterial reconstructions. J Vasc Surg 3:104-114, 1986
    • (1986) J Vasc Surg , vol.3 , pp. 104-114
    • Veith, F.J.1    Gupta, S.K.2    Ascer, E.3
  • 5
    • 0019947720 scopus 로고
    • Femoropopliteal bypass grafts - An isotope technique allowing in vivo comparison of thrombogenicity
    • Goldman M, Norcott HC, Hawker RJ, et al: Femoropopliteal bypass grafts - An isotope technique allowing in vivo comparison of thrombogenicity. Br J Surg 69:380-382, 1982
    • (1982) Br J Surg , vol.69 , pp. 380-382
    • Goldman, M.1    Norcott, H.C.2    Hawker, R.J.3
  • 6
    • 0025721145 scopus 로고
    • Increased blood flow inhibits neointimal hyperplasia in endothelialized vascular grafts
    • Kohler TR, Kirkman TR, Kraiss LW, et al: Increased blood flow inhibits neointimal hyperplasia in endothelialized vascular grafts. Circ Res 69:1557-1565, 1991
    • (1991) Circ Res , vol.69 , pp. 1557-1565
    • Kohler, T.R.1    Kirkman, T.R.2    Kraiss, L.W.3
  • 7
    • 0029399465 scopus 로고
    • Thrombolysis, flow, and vessel wall interactions
    • Grabowski EF: Thrombolysis, flow, and vessel wall interactions. J Vasc Interv Radiol 6:25S-29S, 1995
    • (1995) J Vasc Interv Radiol , vol.6 , pp. 25S-29S
    • Grabowski, E.F.1
  • 8
    • 84970152586 scopus 로고
    • Thrombus formation on polytetrafluoroethylene surfaces: The importance of von Willebrand factor
    • Cho JS, Ouriel K, DeWeese JA, et al: Thrombus formation on polytetrafluoroethylene surfaces: The importance of von Willebrand factor. Cardiovasc Surg 3:645-651, 1995
    • (1995) Cardiovasc Surg , vol.3 , pp. 645-651
    • Cho, J.S.1    Ouriel, K.2    DeWeese, J.A.3
  • 9
    • 0020429395 scopus 로고
    • Effect of increased arterial blood flow on localization and progression of atherosclerosis
    • Towne JB, Quinn K, Salles-Cunha S, et al: Effect of increased arterial blood flow on localization and progression of atherosclerosis. Arch Surg 117:1469-1474, 1982
    • (1982) Arch Surg , vol.117 , pp. 1469-1474
    • Towne, J.B.1    Quinn, K.2    Salles-Cunha, S.3
  • 10
    • 0027691227 scopus 로고
    • The role of fluid mechanics in the localization and detection of atherosclerosis
    • Giddens DP, Zarins CK, Glagov S: The role of fluid mechanics in the localization and detection of atherosclerosis. J Biomech Eng 115:588-594, 1993
    • (1993) J Biomech Eng , vol.115 , pp. 588-594
    • Giddens, D.P.1    Zarins, C.K.2    Glagov, S.3
  • 11
    • 0029026664 scopus 로고
    • Noninvasive determination of shear-rate distribution across the arterial lumen
    • Hoeks AP, Samijo SK, Brands PJ, et al: Noninvasive determination of shear-rate distribution across the arterial lumen. Hypertension 26:26-33, 1995
    • (1995) Hypertension , vol.26 , pp. 26-33
    • Hoeks, A.P.1    Samijo, S.K.2    Brands, P.J.3
  • 12
    • 0030890266 scopus 로고    scopus 로고
    • Computational design of a bypass graft that minimizes wall shear stress gradients in the region of the distal anastomosis
    • Lei M, Archie JP, Kleinstreuer C: Computational design of a bypass graft that minimizes wall shear stress gradients in the region of the distal anastomosis. J Vasc Surg 25:637-646, 1997
    • (1997) J Vasc Surg , vol.25 , pp. 637-646
    • Lei, M.1    Archie, J.P.2    Kleinstreuer, C.3
  • 13
    • 0030891211 scopus 로고    scopus 로고
    • Arterial adaptation to increased wall shear stress
    • Bendick PJ, Juleff RS, Glover JL: Arterial adaptation to increased wall shear stress. Vasc Surg 31:153-161, 1997
    • (1997) Vasc Surg , vol.31 , pp. 153-161
    • Bendick, P.J.1    Juleff, R.S.2    Glover, J.L.3
  • 14
    • 0031347671 scopus 로고    scopus 로고
    • Improved determination of vascular blood flow shear rate using Doppler ultrasound
    • Newport Beach, CA, Feb. 22-28: Physiology and Function from Multidimensional Images, Proceedings
    • Farison JB, Begeman GA, Salles-Cunha SX, et al: Improved determination of vascular blood flow shear rate using Doppler ultrasound. Proceedings of the SPIE International Symposium on Medical Imaging, Newport Beach, CA, Feb. 22-28, 1997, Vol. 3033: Physiology and Function from Multidimensional Images, Proceedings
    • (1997) Proceedings of the SPIE International Symposium on Medical Imaging , vol.3033
    • Farison, J.B.1    Begeman, G.A.2    Salles-Cunha, S.X.3
  • 16
    • 0027209689 scopus 로고
    • The effects of flow on blood coagulation and thrombosis
    • Slack SM, Cui Y, Turitto VT: The effects of flow on blood coagulation and thrombosis. Thromb Haemost 70:129-134, 1993
    • (1993) Thromb Haemost , vol.70 , pp. 129-134
    • Slack, S.M.1    Cui, Y.2    Turitto, V.T.3
  • 17
    • 0002401475 scopus 로고
    • Shear stress in the circulation
    • Bevam JA, Kaley G, Rubanyi GM. New York: Oxford University Press
    • Lipowsky HH: Shear stress in the circulation. In: Flow-Dependent Regulation of Vascular Function, ed. by Bevam JA, Kaley G, Rubanyi GM. New York: Oxford University Press, 1995, pp 28-45
    • (1995) Flow-Dependent Regulation of Vascular Function , pp. 28-45
    • Lipowsky, H.H.1
  • 19
    • 0022003831 scopus 로고
    • Mechanisms of arterial graft failure. 1. Role of cellular proliferation in early healing of PTFE prostheses
    • Clowes AW, Gown AM, Hanson SR, et al: Mechanisms of arterial graft failure. 1. Role of cellular proliferation in early healing of PTFE prostheses. Am J Pathol 118:43-54, 1985
    • (1985) Am J Pathol , vol.118 , pp. 43-54
    • Clowes, A.W.1    Gown, A.M.2    Hanson, S.R.3
  • 20
    • 0022477564 scopus 로고
    • Mechanisms of arterial graft failure. II. Chronic endothelial and smooth muscle cell proliferation in healing polytetrafluoroethylene prostheses
    • Clowes AW, Kirkman TR, Clowes MM: Mechanisms of arterial graft failure. II. Chronic endothelial and smooth muscle cell proliferation in healing polytetrafluoroethylene prostheses. J Vasc Surg 3:877-884, 1986
    • (1986) J Vasc Surg , vol.3 , pp. 877-884
    • Clowes, A.W.1    Kirkman, T.R.2    Clowes, M.M.3
  • 21
    • 0024522606 scopus 로고
    • Fluid flow stimulates tissue plasminogen activator secretion by cultured human endothelial cells
    • Diamond SL, Eskin SG, McIntire LV: Fluid flow stimulates tissue plasminogen activator secretion by cultured human endothelial cells. Science 243:1483-1485, 1989
    • (1989) Science , vol.243 , pp. 1483-1485
    • Diamond, S.L.1    Eskin, S.G.2    McIntire, L.V.3
  • 22
    • 0022380016 scopus 로고
    • Prostacyclin production by cultured endothelial cell monolayers exposed to step increases in shear stress
    • Grabowski EF, Jaffe EA, Weksler BB: Prostacyclin production by cultured endothelial cell monolayers exposed to step increases in shear stress. J Lab Clin Med 105:36-43, 1985
    • (1985) J Lab Clin Med , vol.105 , pp. 36-43
    • Grabowski, E.F.1    Jaffe, E.A.2    Weksler, B.B.3
  • 23
    • 0022896256 scopus 로고
    • Pulsatile perfusion stimulates the release of endothelial autacoids
    • Pohl U, Busse R, Kuon E, et al: Pulsatile perfusion stimulates the release of endothelial autacoids. J Appl Cardiol 1:215-235, 1986
    • (1986) J Appl Cardiol , vol.1 , pp. 215-235
    • Pohl, U.1    Busse, R.2    Kuon, E.3
  • 24
    • 0033051275 scopus 로고    scopus 로고
    • Effect of exercise on hemodynamic conditions in the abdominal aorta
    • Taylor CA, Hughes TJ, Zarins CK: Effect of exercise on hemodynamic conditions in the abdominal aorta. J Vasc Surg 29:1077-1089, 1999
    • (1999) J Vasc Surg , vol.29 , pp. 1077-1089
    • Taylor, C.A.1    Hughes, T.J.2    Zarins, C.K.3
  • 25
    • 0023111956 scopus 로고
    • Shear stress regulation of artery lumen diameter in experimental atherogenesis
    • Zarins CK, Zatina MA, Giddens DP, et al: Shear stress regulation of artery lumen diameter in experimental atherogenesis. J Vasc Surg 5:413-420, 1987
    • (1987) J Vasc Surg , vol.5 , pp. 413-420
    • Zarins, C.K.1    Zatina, M.A.2    Giddens, D.P.3
  • 26
    • 0023105951 scopus 로고
    • Kinetics of vein graft hyperplasia: Association with tangential stress
    • Zwolak RM, Adams MC, Clowes AW: Kinetics of vein graft hyperplasia: Association with tangential stress. J Vasc Surg 5:126-136, 1987
    • (1987) J Vasc Surg , vol.5 , pp. 126-136
    • Zwolak, R.M.1    Adams, M.C.2    Clowes, A.W.3
  • 28
    • 0012011613 scopus 로고
    • Rheology of blood
    • Oxford: Pergamon Press
    • Whitmore RL: Rheology of blood. In: Rheology of the Circulation. Oxford: Pergamon Press, 1968, pp 62-89
    • (1968) Rheology of the Circulation , pp. 62-89
    • Whitmore, R.L.1
  • 29
    • 0034102398 scopus 로고    scopus 로고
    • Improving vascular grafts: The importance of mechanical and haemodynamic properties
    • Greenwald SE, Berry CL: Improving vascular grafts: The importance of mechanical and haemodynamic properties. J Pathol 190:292-299, 2000
    • (2000) J Pathol , vol.190 , pp. 292-299
    • Greenwald, S.E.1    Berry, C.L.2
  • 30
    • 0034646286 scopus 로고    scopus 로고
    • Effects of abciximab, ticlopidine, and combined abciximab/ticlopidine therapy on platelet and leukocyte function in patients undergoing coronary angioplasty
    • Fredrickson BJ, Turner NA, Kleiman NS, et al: Effects of abciximab, ticlopidine, and combined abciximab/ticlopidine therapy on platelet and leukocyte function in patients undergoing coronary angioplasty. Circulation 101:1122-1129, 2000
    • (2000) Circulation , vol.101 , pp. 1122-1129
    • Fredrickson, B.J.1    Turner, N.A.2    Kleiman, N.S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.