-
2
-
-
0023245622
-
Multisection fat-water imaging with chemical shift selective presaturation
-
Keller PJ, Hunter WW Jr, Schmalbrock P. Multisection fat-water imaging with chemical shift selective presaturation. Radiology 1987;164:539-541.
-
(1987)
Radiology
, vol.164
, pp. 539-541
-
-
Keller, P.J.1
Hunter W.W., Jr.2
Schmalbrock, P.3
-
3
-
-
0000598004
-
Minimum-cost presaturation by slice segmentation in fast 2-d gradientecho imaging
-
New York
-
Finn JP, Thomasson DM, Moore JR, Purdy DE, Ascher S, Patt R, Laub G. Minimum-cost presaturation by slice segmentation in fast 2-d gradientecho imaging. In: Proc 4th Annual Scientific Meeting ISMRM, New York, 1996. p 1475.
-
(1996)
Proc 4th Annual Scientific Meeting ISMRM
, pp. 1475
-
-
Finn, J.P.1
Thomasson, D.M.2
Moore, J.R.3
Purdy, D.E.4
Ascher, S.5
Patt, R.6
Laub, G.7
-
4
-
-
0034038214
-
Reduced power multislice MDEFT imaging
-
Norris DG. Reduced power multislice MDEFT imaging. J Magn Reson Imag 2000;11:445-451.
-
(2000)
J Magn Reson Imag
, vol.11
, pp. 445-451
-
-
Norris, D.G.1
-
5
-
-
0034908688
-
FLAIR imaging using nonselective inversion pulses combined with slice excitation order cycling and k-space reordering to reduce flow artifacts
-
Herlihy AH, Oatridge A, Curati WL, Puri PK, Bydder GM, Hajnal JV. FLAIR imaging using nonselective inversion pulses combined with slice excitation order cycling and k-space reordering to reduce flow artifacts. Magn Reson Med 2001;46:354-364.
-
(2001)
Magn Reson Med
, vol.46
, pp. 354-364
-
-
Herlihy, A.H.1
Oatridge, A.2
Curati, W.L.3
Puri, P.K.4
Bydder, G.M.5
Hajnal, J.V.6
-
6
-
-
0000557592
-
Extending the coverage of true volume scans by continuous movement of the subject
-
Philadelphia
-
Dietrich O, Hajnal JV. Extending the coverage of true volume scans by continuous movement of the subject. In: Proc 7th Annual Scientific Meeting ISMRM, Philadelphia, 1999. p 1653.
-
(1999)
Proc 7th Annual Scientific Meeting ISMRM
, pp. 1653
-
-
Dietrich, O.1
Hajnal, J.V.2
-
8
-
-
0034979158
-
Whole-body MR imaging in 30 seconds with real-time true FISP and a continuously rolling table platform: Feasibility study
-
Barkhausen J, Quick HH, Lauenstein T, Goyen M, Ruehm SG, Laub G, Debatin JF, Ladd ME. Whole-body MR imaging in 30 seconds with real-time true FISP and a continuously rolling table platform: Feasibility study. Radiology 2001;220:252-256.
-
(2001)
Radiology
, vol.220
, pp. 252-256
-
-
Barkhausen, J.1
Quick, H.H.2
Lauenstein, T.3
Goyen, M.4
Ruehm, S.G.5
Laub, G.6
Debatin, J.F.7
Ladd, M.E.8
-
10
-
-
0028203418
-
Improved MR angiography: Magnetization transfer suppression with variable flip angle excitation and increased resolution
-
Atkinson D, Brant-Zawadzki M, Gillan G, Purdy D, Laub G. Improved MR angiography: Magnetization transfer suppression with variable flip angle excitation and increased resolution. Radiology 1994;190:890-894.
-
(1994)
Radiology
, vol.190
, pp. 890-894
-
-
Atkinson, D.1
Brant-Zawadzki, M.2
Gillan, G.3
Purdy, D.4
Laub, G.5
-
11
-
-
0027570638
-
Overlapping section coverage in multisection imaging
-
Hennig J. Overlapping section coverage in multisection imaging. J Magn Reson Imag 1993;3:425-432.
-
(1993)
J Magn Reson Imag
, vol.3
, pp. 425-432
-
-
Hennig, J.1
-
12
-
-
0031596291
-
Sliding interleaved ky (SLINKY) acquisition: A novel 3D MRA technique with suppressed slab boundary artifact
-
Liu K, Rutt BK. Sliding interleaved ky (SLINKY) acquisition: A novel 3D MRA technique with suppressed slab boundary artifact. J Magn Reson Imag 1998;8:903-911.
-
(1998)
J Magn Reson Imag
, vol.8
, pp. 903-911
-
-
Liu, K.1
Rutt, B.K.2
-
13
-
-
0025213880
-
2, and chemical-shift imaging
-
2, and chemical-shift imaging. Magn Reson Med 1990;13:77-89.
-
(1990)
Magn Reson Med
, vol.13
, pp. 77-89
-
-
Haase, A.1
|