메뉴 건너뛰기




Volumn 134, Issue 5, 2002, Pages 701-706

Corneal flap displacement and drift in LASIK: Comparison of Hansatome and Automated Corneal Shaper microkeratomes

Author keywords

[No Author keywords available]

Indexed keywords

ACCURACY; ARTICLE; AUTOMATION; CALCULATION; CONTROLLED STUDY; HUMAN; KERATOMILEUSIS; MAJOR CLINICAL STUDY; MEASUREMENT; PRIORITY JOURNAL; PUPIL; STANDARD; SUCTION; VACUUM; VIDEORECORDING;

EID: 0036845720     PISSN: 00029394     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0002-9394(02)01675-6     Document Type: Article
Times cited : (1)

References (16)
  • 1
    • 0026600280 scopus 로고
    • Excimer laser intrastromal keratomileusis
    • Buratto L., Ferrari M., Rama P. Excimer laser intrastromal keratomileusis. Am J Ophthalmol. 113:1992;291-295.
    • (1992) Am J Ophthalmol , vol.113 , pp. 291-295
    • Buratto, L.1    Ferrari, M.2    Rama, P.3
  • 2
    • 0030228786 scopus 로고    scopus 로고
    • The history and evolution of keratomileusis
    • Barraquer J.I. The history and evolution of keratomileusis. Int Ophthalmol Clin. 36:1996;1-7.
    • (1996) Int Ophthalmol Clin , vol.36 , pp. 1-7
    • Barraquer, J.I.1
  • 3
    • 0031866166 scopus 로고    scopus 로고
    • Laser in situ keratomileusis: Literature review of a developing technique
    • Farah S.G., Azar D.T., Gurdal C., Wong J. Laser in situ keratomileusis literature review of a developing technique . J Cataract Refract Surg. 24:1998;989-1006.
    • (1998) J Cataract Refract Surg , vol.24 , pp. 989-1006
    • Farah, S.G.1    Azar, D.T.2    Gurdal, C.3    Wong, J.4
  • 4
    • 0030911075 scopus 로고    scopus 로고
    • Topographical analysis of ablation centration after excimer laser photorefractive keratectomy and laser in situ keratomileusis for high myopia
    • Mulhern M.G., Foley-Nolan A., O'Keefe M., Condon P.I. Topographical analysis of ablation centration after excimer laser photorefractive keratectomy and laser in situ keratomileusis for high myopia. J Cataract Refract Surg. 23:1997;488-494.
    • (1997) J Cataract Refract Surg , vol.23 , pp. 488-494
    • Mulhern, M.G.1    Foley-Nolan, A.2    O'Keefe, M.3    Condon, P.I.4
  • 5
    • 0034019942 scopus 로고    scopus 로고
    • Eye movement during laser in situ keratomileusis
    • Schwiegerling J., Snyder R.W. Eye movement during laser in situ keratomileusis. J Cataract Refract Surg. 26:2000;345-351.
    • (2000) J Cataract Refract Surg , vol.26 , pp. 345-351
    • Schwiegerling, J.1    Snyder, R.W.2
  • 6
    • 0030758402 scopus 로고    scopus 로고
    • Corneal topographic evaluation of decentration in photorefractive keratectomy: Treatment displacement versus intraoperative drift
    • Azar D.T., Yeh P.C. Corneal topographic evaluation of decentration in photorefractive keratectomy treatment displacement versus intraoperative drift . Am J Ophthalmol. 124:1997;312-320.
    • (1997) Am J Ophthalmol , vol.124 , pp. 312-320
    • Azar, D.T.1    Yeh, P.C.2
  • 7
    • 0031658323 scopus 로고    scopus 로고
    • LASIK: Management of common complications. Laser in situ keratomileusis
    • Wilson S.E. LASIK: management of common complications. Laser in situ keratomileusis. Cornea. 17:1998;459-467.
    • (1998) Cornea , vol.17 , pp. 459-467
    • Wilson, S.E.1
  • 8
    • 0034064230 scopus 로고    scopus 로고
    • Retinal detachment following laser in situ keratomileusis
    • Aras C., Ozdamar A., Karacorlu M., et al. Retinal detachment following laser in situ keratomileusis. Ophthalmic Surg Lasers. 31:2000;121-125.
    • (2000) Ophthalmic Surg Lasers , vol.31 , pp. 121-125
    • Aras, C.1    Ozdamar, A.2    Karacorlu, M.3
  • 9
    • 0034109428 scopus 로고    scopus 로고
    • Photorefractive keratectomy versus laser in situ keratomileusis: A control-matched study
    • Pop M., Payette Y. Photorefractive keratectomy versus laser in situ keratomileusis a control-matched study . Ophthalmology. 107:2000;251-257.
    • (2000) Ophthalmology , vol.107 , pp. 251-257
    • Pop, M.1    Payette, Y.2
  • 10
    • 0031790753 scopus 로고    scopus 로고
    • Incidence and management of intraoperative and early postoperative complications in 1000 consecutive laser in situ keratomileusis cases
    • Gimbel H.V., Anderson Penno E.E., van Westenbrugge J.A., et al. Incidence and management of intraoperative and early postoperative complications in 1000 consecutive laser in situ keratomileusis cases. Ophthalmology. 105:1998;1839-1848.
    • (1998) Ophthalmology , vol.105 , pp. 1839-1848
    • Gimbel, H.V.1    Anderson Penno, E.E.2    Van Westenbrugge, J.A.3
  • 11
    • 0033045480 scopus 로고    scopus 로고
    • Surgically induced astigmatism after photorefractive keratectomy and laser in situ keratomileusis
    • Hersh P.S., Abbassi R., Summit PRK-LASIK Study Group . Surgically induced astigmatism after photorefractive keratectomy and laser in situ keratomileusis. J Cataract Refract Surg. 25:1999;389-398.
    • (1999) J Cataract Refract Surg , vol.25 , pp. 389-398
    • Hersh, P.S.1    Abbassi, R.2
  • 12
    • 0031711020 scopus 로고    scopus 로고
    • Corneal topography in LASIK
    • Oshika T., Klyce S.D. Corneal topography in LASIK. Sem Ophthalmol. 13:1998;64-70.
    • (1998) Sem Ophthalmol , vol.13 , pp. 64-70
    • Oshika, T.1    Klyce, S.D.2
  • 13
    • 0031790644 scopus 로고    scopus 로고
    • Interface inflammation after laser in situ keratomileusis: Sands of the Sahara syndrome
    • Kaufman S.C., Maitchouk D.Y., Chiou A.G.Y., Beuerman R.W. Interface inflammation after laser in situ keratomileusis sands of the Sahara syndrome . J Cataract Refract Surg. 24:1998;1589-1593.
    • (1998) J Cataract Refract Surg , vol.24 , pp. 1589-1593
    • Kaufman, S.C.1    Maitchouk, D.Y.2    Chiou, A.G.Y.3    Beuerman, R.W.4
  • 14
    • 0033979828 scopus 로고    scopus 로고
    • Optical disturbances and their management after myopic laser in situ keratomileusis
    • Melki S.A., Proano C.E., Azar D.T. Optical disturbances and their management after myopic laser in situ keratomileusis. Int Ophthalmol Clin. 40:2000;45-56.
    • (2000) Int Ophthalmol Clin , vol.40 , pp. 45-56
    • Melki, S.A.1    Proano, C.E.2    Azar, D.T.3
  • 15
    • 0030883310 scopus 로고    scopus 로고
    • Indications, techniques, results, limits, and complications of laser in situ keratomileusis
    • Buratto L., Ferrari M. Indications, techniques, results, limits, and complications of laser in situ keratomileusis. Curr Opin Ophthalmol. 8:1997;59-66.
    • (1997) Curr Opin Ophthalmol , vol.8 , pp. 59-66
    • Buratto, L.1    Ferrari, M.2
  • 16
    • 0033956692 scopus 로고    scopus 로고
    • Lower intraoperative flap complication rate with the Hansatome microkeratome compared to the Automated Corneal Shaper
    • Walker M.B., Wilson S.E. Lower intraoperative flap complication rate with the Hansatome microkeratome compared to the Automated Corneal Shaper. J Refract Surg. 16:2000;79-82.
    • (2000) J Refract Surg , vol.16 , pp. 79-82
    • Walker, M.B.1    Wilson, S.E.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.