Volumn 21, Issue 8, 2002, Pages 745-750

Use of a portable topography machine for screening donor tissue for prior refractive surgery

Author keywords

Cornea; Donor; Eye bank; Hyperopia; LASIK; Myopia; Photorefractive keratectomy; Screening; Topography

Indexed keywords

ADULT; AGED; ARTICLE; ASTIGMATISM; CLINICAL ARTICLE; CORNEA; CORNEA SURGERY; CORRELATION ANALYSIS; DEVICE; ENUCLEATION; EYEBANK; HUMAN; HUMAN TISSUE; HYPERMETROPIA; KERATOMETRY; KERATOTOMY; LABORATORY DIAGNOSIS; MYOPIA; ORGAN DONOR; PRIORITY JOURNAL; REFRACTION ERROR; SCREENING TEST; STATISTICAL SIGNIFICANCE; TECHNOLOGY; TISSUE STRUCTURE;

EID: 0036827587     PISSN: 02773740     EISSN: None     Source Type: Journal    
DOI: 10.1097/00003226-200211000-00002     Document Type: Article
Times cited : (14)

References (14)
  • 1
    • 0004206350 scopus 로고    scopus 로고
    • December
    • Eye Bank Association of America. Medical Standards. December 2001:9.
    • (2001) Medical Standards , pp. 9
  • 2
    • 0036187230 scopus 로고    scopus 로고
    • Objective screening methods for prior refractive surgery in donor tissue
    • Ousley PJ, Terry MA. Objective screening methods for prior refractive surgery in donor tissue. Cornea 2002;21:181-8.
    • (2002) Cornea , vol.21 , pp. 181-188
    • Ousley, P.J.1    Terry, M.A.2
  • 3
    • 0032949826 scopus 로고    scopus 로고
    • Evaluation of prior photorefractive keratectomy in donor tissue
    • Terry MA, Ousley PJ, Rich LF, et al. Evaluation of prior photorefractive keratectomy in donor tissue. Cornea 1999;18:353-8.
    • (1999) Cornea , vol.18 , pp. 353-358
    • Terry, M.A.1    Ousley, P.J.2    Rich, L.F.3
  • 4
    • 0033017399 scopus 로고    scopus 로고
    • New screening methods for donor eye-bank eyes
    • Terry MA, Ousley PJ. New screening methods for donor eye-bank eyes. Cornea 1999;18:430-6.
    • (1999) Cornea , vol.18 , pp. 430-436
    • Terry, M.A.1    Ousley, P.J.2
  • 5
    • 0030817350 scopus 로고    scopus 로고
    • Screening donor corneas that have undergone PRK
    • Mannis MJ, McDonough G, Howard K, et al. Screening donor corneas that have undergone PRK. Cornea 1997;16:683-5.
    • (1997) Cornea , vol.16 , pp. 683-685
    • Mannis, M.J.1    McDonough, G.2    Howard, K.3
  • 7
    • 0025322759 scopus 로고
    • Classification of normal corneal topography based on computer-assisted videokeratography
    • Bogan SJ, Waring GO, Ibrahim O. et al. Classification of normal corneal topography based on computer-assisted videokeratography. Arch Ophthalmol 1990;108:945-9.
    • (1990) Arch Ophthalmol , vol.108 , pp. 945-949
    • Bogan, S.J.1    Waring, G.O.2    Ibrahim, O.3
  • 8
    • 0029056784 scopus 로고
    • Corneal topography of phase III excimer laser photorefractive keratectomy: Characterization and clinical effects
    • The Summit Photorefractive Keratectomy Topography Study Group
    • Hersh PS, Schwartz-Goldstein BH. The Summit Photorefractive Keratectomy Topography Study Group. Corneal topography of phase III excimer laser photorefractive keratectomy: Characterization and clinical effects. Ophthalmology 1995;102:963-78.
    • (1995) Ophthalmology , vol.102 , pp. 963-978
    • Hersh, P.S.1    Schwartz-Goldstein, B.H.2
  • 9
    • 0034282121 scopus 로고    scopus 로고
    • The accuracy and precision performance of four videokeratoscopes in measuring test surfaces
    • Tang W, Collins MJ, Carney L, et al. The accuracy and precision performance of four videokeratoscopes in measuring test surfaces. Optom Vis Sci 2000;77:483-91.
    • (2000) Optom Vis Sci , vol.77 , pp. 483-491
    • Tang, W.1    Collins, M.J.2    Carney, L.3
  • 10
    • 0031426151 scopus 로고    scopus 로고
    • Topography of corneal grafts before and after penetrating keratoplasty
    • Hjortdal JO, Ehlers N, Erdmann L. Topography of corneal grafts before and after penetrating keratoplasty. Acta Ophthalmol Scand 1997;75:645-8.
    • (1997) Acta Ophthalmol Scand , vol.75 , pp. 645-648
    • Hjortdal, J.O.1    Ehlers, N.2    Erdmann, L.3
  • 11
    • 0028067742 scopus 로고
    • Demonstration of feasibility of application of a portable keratometer to cadaveric donor corneas
    • Dave AS, McCulley JP. Demonstration of feasibility of application of a portable keratometer to cadaveric donor corneas. Cornea 1994;13:379-82.
    • (1994) Cornea , vol.13 , pp. 379-382
    • Dave, A.S.1    McCulley, J.P.2
  • 12
    • 0034757685 scopus 로고    scopus 로고
    • Evaluation of donor tissue with a new videokeratoscope: The Keratron Scout
    • Stoiber J, Ruckhofer J, Hitzl W, et al. Evaluation of donor tissue with a new videokeratoscope: The Keratron Scout. Cornea 2001;20:859-63.
    • (2001) Cornea , vol.20 , pp. 859-863
    • Stoiber, J.1    Ruckhofer, J.2    Hitzl, W.3
  • 13
    • 0005013670 scopus 로고    scopus 로고
    • Epithelial defects in human eyebank mimic pathologic corneal topography
    • Ogawa GSH, Schelonka LP. Epithelial defects in human eyebank mimic pathologic corneal topography. Invest Ophthalmol Vis Sci 1996:37:S562.
    • (1996) Invest Ophthalmol Vis Sci , vol.37
    • Ogawa, G.S.H.1    Schelonka, L.P.2
  • 14
    • 0028862943 scopus 로고
    • Primary corneal graft failure: A national reporting system
    • Wilhelmus KR, Stulting RD, Sugar J, et al. and The Medical Advisory Board of the Eye Bank Association of America. Primary corneal graft failure: A national reporting system. Arch Ophthalmol 1995;113:1497-502.
    • (1995) Arch Ophthalmol , vol.113 , pp. 1497-1502
    • Wilhelmus, K.R.1    Stulting, R.D.2    Sugar, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.