Longitudinal quality control methodology for the quantitative ultrasound Achilles+ in clinical trial settings

Author keywords

Broadband ultrasound attenuation; Phantom; Quality control; Quantitative ultrasound; Speed of sound

Indexed keywords

ACCURACY; ARTICLE; BONE DENSITY; CONFIDENCE INTERVAL; DEVICE; DUAL ENERGY X RAY ABSORPTIOMETRY; PHANTOM; PRIORITY JOURNAL; QUALITY CONTROL; QUANTITATIVE ULTRASOUND; SOUND; TEMPERATURE; ULTRASOUND;

EID: 0036821093     PISSN: 0937941X     EISSN: None     Source Type: Journal    
DOI: 10.1007/s001980200109     Document Type: Article
Times cited : (11)

References (20)
  • 1
    • 0012416831 scopus 로고    scopus 로고
    • Quality assurance and quality control in quantitative ultrasound
    • Njeh CF, Fuerst T, Glüer CC, Genant HK, eds. Martin Dunitz, London
    • Fuerst T, Njeh CF, Hans D. Quality assurance and quality control in quantitative ultrasound. In Njeh CF, Fuerst T, Glüer CC, Genant HK, eds. Quantitative ultrasound: assessment of osteoporosis and bone status. Martin Dunitz, London, 163-75.
    • Quantitative Ultrasound: Assessment of Osteoporosis and Bone Status , pp. 163-175
    • Fuerst, T.1    Njeh, C.F.2    Hans, D.3
  • 2
    • 0012419723 scopus 로고    scopus 로고
    • Good clinical practice and audits for dual x-ray absorptiometry and x-ray imaging laboratories and quality assurance centers involved in clinical drug trials, private practice and research
    • Blunt B, Jones D, Svensen R, Hans D, Feinblatt J, Genant H. Good clinical practice and audits for dual x-ray absorptiometry and x-ray imaging laboratories and quality assurance centers involved in clinical drug trials, private practice and research. J Clin Dens 1998;1:323-37.
    • (1998) J Clin Dens , vol.1 , pp. 323-337
    • Blunt, B.1    Jones, D.2    Svensen, R.3    Hans, D.4    Feinblatt, J.5    Genant, H.6
  • 3
    • 0028991317 scopus 로고
    • Quality control of DXA instruments in multicenter trials
    • Faulkner KG, McClung MR. Quality control of DXA instruments in multicenter trials. Osteoporos Int 1995;5:218-27.
    • (1995) Osteoporos Int , vol.5 , pp. 218-227
    • Faulkner, K.G.1    McClung, M.R.2
  • 4
    • 0030914386 scopus 로고    scopus 로고
    • DXA longitudinal quality control: A comparison of inbuilt quality assurance, visual inspection, multi-rule Shewhart charts and Cusum analysis
    • Garland SW, Lees B, Stevenson JC. DXA longitudinal quality control: a comparison of inbuilt quality assurance, visual inspection, multi-rule Shewhart charts and Cusum analysis. Osteoporos Int 1997;7:231-7.
    • (1997) Osteoporos Int , vol.7 , pp. 231-237
    • Garland, S.W.1    Lees, B.2    Stevenson, J.C.3
  • 5
    • 0030837374 scopus 로고    scopus 로고
    • Long-term quality control of DXA: A comparison of Shewhart rules and Cusum charts
    • Pearson D, Cawte SA. Long-term quality control of DXA: a comparison of Shewhart rules and Cusum charts. Osteoporos Int 1997;7:338-43.
    • (1997) Osteoporos Int , vol.7 , pp. 338-343
    • Pearson, D.1    Cawte, S.A.2
  • 6
    • 15844376474 scopus 로고    scopus 로고
    • Dual X-ray absorptiometry quality control: Comparison of visual examination and process-control charts
    • Lu Y, Mathur AK, Blunt BA, et al. Dual X-ray absorptiometry quality control: comparison of visual examination and process-control charts. J Bone Miner Res 1996;11:626-37.
    • (1996) J Bone Miner Res , vol.11 , pp. 626-637
    • Lu, Y.1    Mathur, A.K.2    Blunt, B.A.3
  • 8
    • 84970860170 scopus 로고
    • Statistics notes: The normal distribution
    • Altman DG, Bland JM. Statistics notes: the normal distribution. BMJ 1995;310:298.
    • (1995) BMJ , vol.310 , pp. 298
    • Altman, D.G.1    Bland, J.M.2
  • 9
    • 0016514361 scopus 로고
    • An inventory of biostatistics teaching in American and Canadian Medical Schools
    • Colton T. An inventory of biostatistics teaching in American and Canadian Medical Schools. J Med Educ 1975;50:596-604.
    • (1975) J Med Educ , vol.50 , pp. 596-604
    • Colton, T.1
  • 10
    • 0029112340 scopus 로고
    • Accurate assessment of precision errors: How to measure the reproducibility of bone densitometry techniques
    • Gluer CC, Blake G, Lu Y, Blunt BA, Jergas M, Genant HK. Accurate assessment of precision errors: how to measure the reproducibility of bone densitometry techniques. Osteoporos Int 1995;5:262-70.
    • (1995) Osteoporos Int , vol.5 , pp. 262-270
    • Gluer, C.C.1    Blake, G.2    Lu, Y.3    Blunt, B.A.4    Jergas, M.5    Genant, H.K.6
  • 12
    • 25344464997 scopus 로고    scopus 로고
    • Can a Cusum chart detect change points in longitudinal, quantitative ultrasound quality control data: Study with the Achilles plus
    • Hans D, Srivastav S, Lu Y, et al. Can a Cusum chart detect change points in longitudinal, quantitative ultrasound quality control data: study with the Achilles plus. J Bone Miner Res 1999;14(suppl. 1):S376.
    • (1999) J Bone Miner Res , vol.14 , Issue.SUPPL. 1
    • Hans, D.1    Srivastav, S.2    Lu, Y.3
  • 13
    • 0012478170 scopus 로고    scopus 로고
    • In vitro (phantom) cross calibration of quantitative ultrasound devices
    • Njeh C, Chen M, Fan B, et al. In vitro (phantom) cross calibration of quantitative ultrasound devices. Osteoporos Int 2000;11(suppl 3):14.
    • (2000) Osteoporos Int , vol.11 , Issue.SUPPL. 3 , pp. 14
    • Njeh, C.1    Chen, M.2    Fan, B.3
  • 14
    • 0012381999 scopus 로고    scopus 로고
    • Evaluation of two quantitative ultrasound phantoms for use in daily quality assurance
    • Gumy C, Alekxandrova I, Perron C, Slosman D, Hans D. Evaluation of two quantitative ultrasound phantoms for use in daily quality assurance. Osteoporos Int 2000;11(Suppl. 3):14.
    • (2000) Osteoporos Int , vol.11 , Issue.SUPPL. 3 , pp. 14
    • Gumy, C.1    Alekxandrova, I.2    Perron, C.3    Slosman, D.4    Hans, D.5
  • 15
    • 4244017284 scopus 로고    scopus 로고
    • The impact of temperature on quantitative ultrasound: An in vitro study using phantoms
    • Njeh C, Chen M, Fan B, et al. The impact of temperature on quantitative ultrasound: an in vitro study using phantoms. J Bone Miner Res 14(suppl 1):S500.
    • J Bone Miner Res , vol.14 , Issue.SUPPL. 1
    • Njeh, C.1    Chen, M.2    Fan, B.3
  • 16
    • 0002285684 scopus 로고
    • Temperature and direction dependence of the attenuation and velocity of ultrasound in cancellous and cortical bone
    • Ring EFG, Bhalia AK, eds. British Institute of Radiology: London
    • Evans JA, Tavakoli MB. Temperature and direction dependence of the attenuation and velocity of ultrasound in cancellous and cortical bone. In: Ring EFG, Bhalia AK, eds. Current research in osteoporosis and bone measurement II. British Institute of Radiology: London, 1992:43.
    • (1992) Current Research in Osteoporosis and Bone Measurement II , pp. 43
    • Evans, J.A.1    Tavakoli, M.B.2
  • 17
    • 0028893126 scopus 로고
    • Factors affecting the in vivo precision of broad-band ultrasonic attenuation
    • Evans WD, Jones EA, Owen GM. Factors affecting the in vivo precision of broad-band ultrasonic attenuation. Phys Med Biol 1995;40:137-51.
    • (1995) Phys Med Biol , vol.40 , pp. 137-151
    • Evans, W.D.1    Jones, E.A.2    Owen, G.M.3
  • 18
    • 0029865461 scopus 로고    scopus 로고
    • Ultrasound parametric imaging of the calcaneus: In vivo results with a new device
    • Laugier P, Fournier B, Berger G. Ultrasound parametric imaging of the calcaneus: in vivo results with a new device, Calcif Tissue Int 1996;58:326-31.
    • (1996) Calcif Tissue Int , vol.58 , pp. 326-331
    • Laugier, P.1    Fournier, B.2    Berger, G.3
  • 19
    • 0012453030 scopus 로고    scopus 로고
    • Development of an electronic phantom for calibration, cross-correlation and quality assurance of broadband ultrasound attenuation measurement in the calcaneus
    • Langton CM. Development of an electronic phantom for calibration, cross-correlation and quality assurance of broadband ultrasound attenuation measurement in the calcaneus (Abstract). Osteoporos Int 1997;7:309.
    • (1997) Osteoporos Int , vol.7 , pp. 309
    • Langton, C.M.1
  • 20
    • 0012461722 scopus 로고    scopus 로고
    • Quality control in ultrasound: Electronic phantom versus in vivo measurements
    • Alekxandrova I, Slosman D, Hans D. Quality control in ultrasound: electronic phantom versus in vivo measurements. Osteoporos Int 2000;11(suppl. 3):14.
    • (2000) Osteoporos Int , vol.11 , Issue.SUPPL. 3 , pp. 14
    • Alekxandrova, I.1    Slosman, D.2    Hans, D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.