1
-
-
0026544501
-
Does improved depth dose characteristics and treatment planning correlate with a gain in therapeutic results?
-
R. C. Urtasun, "Does improved depth dose characteristics and treatment planning correlate with a gain in therapeutic results?," Int. J. Radiat. Oncol., Biol., Phys. 22, 235-239 (1992).
-
(1992)
Int. J. Radiat. Oncol., Biol., Phys.
, vol.22
, pp. 235-239
-
-
Urtasun, R.C.1
-
2
-
-
0028903082
-
Advances in radiation therapy for head and neck cancer
-
P. Harari and T. Kinsella, "Advances in radiation therapy for head and neck cancer," Curr. Opin. Oncol. 7, 248-254 (1995).
-
(1995)
Curr. Opin. Oncol.
, vol.7
, pp. 248-254
-
-
Harari, P.1
Kinsella, T.2
-
3
-
-
0030248816
-
Parotid gland sparing in patients undergoing bilateral head and neck irradiation: Techniques and early results
-
A. Eisbruch, J. A. Ship, and M. K. Martel. "Parotid gland sparing in patients undergoing bilateral head and neck irradiation: Techniques and early results," Int. J. Radiat. Oncol., Biol., Phys. 36, 469-480 (1996).
-
(1996)
Int. J. Radiat. Oncol., Biol., Phys.
, vol.36
, pp. 469-480
-
-
Eisbruch, A.1
Ship, J.A.2
Martel, M.K.3
-
4
-
-
0031749966
-
Comprehensive irradiation of head and neck cancer using conformal multisegmental fields: Assessment of target coverage and noninvolved tissue sparing
-
A. Eisbruch, L. H. Marsh, and M. K. Martel, "Comprehensive irradiation of head and neck cancer using conformal multisegmental fields: Assessment of target coverage and noninvolved tissue sparing," Int. J. Radiat. Oncol., Biol., Phys. 41, 559-568 (1998).
-
(1998)
Int. J. Radiat. Oncol., Biol., Phys.
, vol.41
, pp. 559-568
-
-
Eisbruch, A.1
Marsh, L.H.2
Martel, M.K.3
-
5
-
-
0032850759
-
Dose, volume, and function in parotid salivary glands following conformal and intensity modulated irradiation of head and neck cancer
-
A. Eisbruch, R. K. Ten Haken, and M. K. Hyungjin, "Dose, volume, and function in parotid salivary glands following conformal and intensity modulated irradiation of head and neck cancer," Int. J. Radiat. Oncol., Biol., Phys. 45, 577-587 (1999).
-
(1999)
Int. J. Radiat. Oncol., Biol., Phys.
, vol.45
, pp. 577-587
-
-
Eisbruch, A.1
Ten Haken, R.K.2
Hyungjin, M.K.3
-
6
-
-
0030610910
-
Dosimetric evaluation of compensation in radiotherapy of the breast: MLC intensity modulation and physical compensators
-
V. Hansen, P. Evans, G. Shentall, S. Helyer, J. Yarnold, and W. Swindell, "Dosimetric evaluation of compensation in radiotherapy of the breast: MLC intensity modulation and physical compensators," Radiother. Oncol. 42, 249-256 (1997).
-
(1997)
Radiother. Oncol.
, vol.42
, pp. 249-256
-
-
Hansen, V.1
Evans, P.2
Shentall, G.3
Helyer, S.4
Yarnold, J.5
Swindell, W.6
-
7
-
-
0029929908
-
Matching of electron beam for conformal therapy of target volumes at moderate depths
-
B. Zackrisson and M. Karlsson, "Matching of electron beam for conformal therapy of target volumes at moderate depths," Radiother. Oncol. 39, 261-270 (1996).
-
(1996)
Radiother. Oncol.
, vol.39
, pp. 261-270
-
-
Zackrisson, B.1
Karlsson, M.2
-
8
-
-
0030294726
-
Feasibility study of multileaf collimated electrons with a scattering foil based accelerator
-
E. Klein, E. Z. Li, and D. Low. "Feasibility study of multileaf collimated electrons with a scattering foil based accelerator," Radiother. Oncol. 41, 189-196 (1996).
-
(1996)
Radiother. Oncol.
, vol.41
, pp. 189-196
-
-
Klein, E.1
Li, E.Z.2
Low, D.3
-
9
-
-
0031762438
-
Modulated electron beams using multi-segmented multileaf collimation with a scattering foil based accelerator
-
E. Klein, "Modulated electron beams using multi-segmented multileaf collimation with a scattering foil based accelerator," Radiother. Oncol. 48, 307-311 (1998).
-
(1998)
Radiother. Oncol.
, vol.48
, pp. 307-311
-
-
Klein, E.1
-
10
-
-
0028144837
-
Generation of arbitrary intensity profiles by dynamic jaws or multileaf collimators
-
S. V. Spirou and C. S. Chui, "Generation of arbitrary intensity profiles by dynamic jaws or multileaf collimators," Med. Phys. 21, 1031-1041 (1994).
-
(1994)
Med. Phys.
, vol.21
, pp. 1031-1041
-
-
Spirou, S.V.1
Chui, C.S.2
-
11
-
-
0026661373
-
The generation of intensity modulated fields for conformal radiotherapy by dynamic collimation
-
D. J. Convery and M. E. Rosenbloom, "The generation of intensity modulated fields for conformal radiotherapy by dynamic collimation," Phys. Med. Biol. 37, 1359-1374 (1992).
-
(1992)
Phys. Med. Biol.
, vol.37
, pp. 1359-1374
-
-
Convery, D.J.1
Rosenbloom, M.E.2
-
12
-
-
0028153801
-
An analytical solution for the dynamic control of multileaf collimators
-
R. Svensson, P. Kallman, and A. Brahme, "An analytical solution for the dynamic control of multileaf collimators," Phys. Med. Biol. 39, 37-61 (1994).
-
(1994)
Phys. Med. Biol.
, vol.39
, pp. 37-61
-
-
Svensson, R.1
Kallman, P.2
Brahme, A.3
-
13
-
-
0029001013
-
A method for implementing dynamic photon beam intensity modulation using independent jaws and a multileaf collimator
-
C. Yu, M. Symons, M. Du, A. Martinez, and J. Wong, "A method for implementing dynamic photon beam intensity modulation using independent jaws and a multileaf collimator," Phys. Med. Biol. 40, 769-787 (1995).
-
(1995)
Phys. Med. Biol.
, vol.40
, pp. 769-787
-
-
Yu, C.1
Symons, M.2
Du, M.3
Martinez, A.4
Wong, J.5
-
14
-
-
0028077046
-
Dynamic x-ray compensation for conformal radiotherapy by means of multileaf collimation
-
J. Stein, T. Bortfeld, B. Dörschel, and W. Schlegel, "Dynamic x-ray compensation for conformal radiotherapy by means of multileaf collimation," Radiother. Oncol. 32, 163-173 (1994).
-
(1994)
Radiother. Oncol.
, vol.32
, pp. 163-173
-
-
Stein, J.1
Bortfeld, T.2
Dörschel, B.3
Schlegel, W.4
-
15
-
-
0030826242
-
Modulated beam conformal therapy for head and neck tumours
-
A. Boyer, P. Geis, W. Grant, and M. Carol, "Modulated beam conformal therapy for head and neck tumours." Int. J. Radiat. Oncol., Biol., Phys. 39, 227-236 (1997).
-
(1997)
Int. J. Radiat. Oncol., Biol., Phys.
, vol.39
, pp. 227-236
-
-
Boyer, A.1
Geis, P.2
Grant, W.3
Carol, M.4
-
16
-
-
0030234045
-
Planning and delivering high doses to targets surrounding the spinal cord at the lower neck and upper mediastinal levels: Static beam-segmentation technique executed with a multileaf collimator
-
W. De Neve, C. De Wagter, K. De Jaeger, M. Thienpont, C. Colle, S. Derycke, and J. Schelfhout, "Planning and delivering high doses to targets surrounding the spinal cord at the lower neck and upper mediastinal levels: static beam-segmentation technique executed with a multileaf collimator," Radiother. Oncol. 40, 271-279 (1996).
-
(1996)
Radiother. Oncol.
, vol.40
, pp. 271-279
-
-
De Neve, W.1
De Wagter, C.2
De Jaeger, K.3
Thienpont, M.4
Colle, C.5
Derycke, S.6
Schelfhout, J.7
-
18
-
-
0027141318
-
Tomotherapy: A new concept for the delivery of dynamic conformal radiotherapy
-
T. R. Mackie, T. Holmes, S. Swerdloff, P. J. Reckwerdt, J. Deasy, J. Yang, B. Paliwal, and T. Kinsella, "Tomotherapy: a new concept for the delivery of dynamic conformal radiotherapy," Med. Phys. 20, 1709-1719 (1993).
-
(1993)
Med. Phys.
, vol.20
, pp. 1709-1719
-
-
Mackie, T.R.1
Holmes, T.2
Swerdloff, S.3
Reckwerdt, P.J.4
Deasy, J.5
Yang, J.6
Paliwal, B.7
Kinsella, T.8
-
19
-
-
0002526593
-
Tomotherapy
-
edited by J. Van Dyk (Medical Physics Publishing, Madison)
-
G. H. Olivera, D. M. Shepard, K. J. Ruchala, J. S. Aldridge, J. M. Kapatoes, E. E. Fitchard, P. J. Reckwerdt, G. Fang, J. Balog, J. Zachman, and T. R. Mackie, "Tomotherapy," in Modern Technology of Radiation Oncology, edited by J. Van Dyk (Medical Physics Publishing, Madison, 1999), pp. 521-587).
-
(1999)
Modern Technology of Radiation Oncology
, pp. 521-587
-
-
Olivera, G.H.1
Shepard, D.M.2
Ruchala, K.J.3
Aldridge, J.S.4
Kapatoes, J.M.5
Fitchard, E.E.6
Reckwerdt, P.J.7
Fang, G.8
Balog, J.9
Zachman, J.10
Mackie, T.R.11
-
20
-
-
0032972749
-
Tomotherapy
-
T. R. Mackie, J. Balog, K. J. Ruchala, D. Shepard, J. S. Aldridge, E. E. Fitchard, P. Reckwerdt, G. H. Olivera, T. McNutt, and M. Mehta, "Tomotherapy," Semin Radiat. Oncol. 9, 108-117 (1999).
-
(1999)
Semin Radiat. Oncol.
, vol.9
, pp. 108-117
-
-
Mackie, T.R.1
Balog, J.2
Ruchala, K.J.3
Shepard, D.4
Aldridge, J.S.5
Fitchard, E.E.6
Reckwerdt, P.7
Olivera, G.H.8
McNutt, T.9
Mehta, M.10
-
21
-
-
0031830812
-
A little to a lot or lot to a little: Is NTCP always minimised in multiport therapy
-
M. Zaider and H. Amols, "A little to a lot or lot to a little: is NTCP always minimised in multiport therapy." Int. J. Radiat. Oncol., Biol., Phys. 41, 945-950 (1998).
-
(1998)
Int. J. Radiat. Oncol., Biol., Phys.
, vol.41
, pp. 945-950
-
-
Zaider, M.1
Amols, H.2
-
22
-
-
0030796894
-
Abutment region dosimetry for sequential arc IMRT delivery
-
D. A. Low and S. Mutic. "Abutment region dosimetry for sequential arc IMRT delivery," Phys. Med. Biol. 42, 1465-1470 (1997).
-
(1997)
Phys. Med. Biol.
, vol.42
, pp. 1465-1470
-
-
Low, D.A.1
Mutic, S.2
-
23
-
-
0032823683
-
Megavoltage CT on a tomotherapy system
-
K. J. Ruchala, G. H. Olivera, E. A. Schloesser, and T. R. Mackie, "Megavoltage CT on a tomotherapy system," Phys. Med. Biol. 44, 2597-2621 (1999).
-
(1999)
Phys. Med. Biol.
, vol.44
, pp. 2597-2621
-
-
Ruchala, K.J.1
Olivera, G.H.2
Schloesser, E.A.3
Mackie, T.R.4
-
24
-
-
0034536973
-
Megavoltage CT image reconstruction during tomotherapy treatments
-
K. J. Ruchala, G. H. Olivera, J. M. Kapatoes. E. A. Schloesser, P. J. Reckwerdt, and T. R. Mackie, "Megavoltage CT image reconstruction during tomotherapy treatments," Phys. Med. Biol. 45, 3545-3562 (2000).
-
(2000)
Phys. Med. Biol.
, vol.45
, pp. 3545-3562
-
-
Ruchala, K.J.1
Olivera, G.H.2
Kapatoes, J.M.3
Schloesser, E.A.4
Reckwerdt, P.J.5
Mackie, T.R.6
-
25
-
-
0033930039
-
Megavoltage CT imaging as a byproduct of multileaf collimator leakage
-
K. J. Ruchala, G. H. Olivera, J. M. Kapatoes, E. A. Schloesser, P. J. Reckwerdt, and T. R. Mackie, "Megavoltage CT imaging as a byproduct of multileaf collimator leakage," Phys. Med. Biol. 45, N61-N70 (2000).
-
(2000)
Phys. Med. Biol.
, vol.45
-
-
Ruchala, K.J.1
Olivera, G.H.2
Kapatoes, J.M.3
Schloesser, E.A.4
Reckwerdt, P.J.5
Mackie, T.R.6
-
26
-
-
0034038104
-
Calibration of a tomotherapeutic megavoltage CT system
-
K. J. Ruchala, G. H. Olivera, E. A. Schloesser, R. Hinderer, and T. R. Mackie, "Calibration of a tomotherapeutic megavoltage CT system," Phys. Med. Biol. 45, N27-N36 (2000).
-
(2000)
Phys. Med. Biol.
, vol.45
-
-
Ruchala, K.J.1
Olivera, G.H.2
Schloesser, E.A.3
Hinderer, R.4
Mackie, T.R.5
-
27
-
-
0032782994
-
Image/patient registration from (partial) projection data by the Fourier phase matching method
-
W. Lu, E. E. Fitchard, G. H. Olivera, J. S. Aldridge, J. You, K. J. Ruchala, J. S. Aldridge, and T. R. Mackie, "Image/patient registration from (partial) projection data by the Fourier phase matching method." Phys. Med. Biol. 44, 2029-2048 (1999).
-
(1999)
Phys. Med. Biol.
, vol.44
, pp. 2029-2048
-
-
Lu, W.1
Fitchard, E.E.2
Olivera, G.H.3
Aldridge, J.S.4
You, J.5
Ruchala, K.J.6
Aldridge, J.S.7
Mackie, T.R.8
-
28
-
-
0032934376
-
Registration using tomographic projection files
-
E. E. Fitchard, J. S. Aldridge, K. J. Ruchala, G. Fang, J. P. Balog, D. W. Pearson, G. H. Olivera, E. A. Schloesser, D. Wenman, P. J. Reckwerdt, and T. R. Mackie, "Registration using tomographic projection files," Phys. Med. Biol. 44, 495-507 (1999).
-
(1999)
Phys. Med. Biol.
, vol.44
, pp. 495-507
-
-
Fitchard, E.E.1
Aldridge, J.S.2
Ruchala, K.J.3
Fang, G.4
Balog, J.P.5
Pearson, D.W.6
Olivera, G.H.7
Schloesser, E.A.8
Wenman, D.9
Reckwerdt, P.J.10
Mackie, T.R.11
-
29
-
-
0032778206
-
Six parameter patient registration directly from projection data
-
E. E. Fitchard, J. S. Aldridge, P. J. Reckwerdt, A. Iosevich, G. H. Olivera, and T. R. Mackie, "Six parameter patient registration directly from projection data," Nucl. Instrum. Methods Phys. Res. A 421, 342-351 (1999).
-
(1999)
Nucl. Instrum. Methods Phys. Res. A
, vol.421
, pp. 342-351
-
-
Fitchard, E.E.1
Aldridge, J.S.2
Reckwerdt, P.J.3
Iosevich, A.4
Olivera, G.H.5
Mackie, T.R.6
-
30
-
-
0001053287
-
Delivery modification as an alternative to patient repositioning in tomotherapy
-
edited by W. Schlegel and T. Bortfeld (Springer, Berlin)
-
G. H. Olivera, E. E. Fitchard, P. J. Reckwerdt, K. J. Ruchala, and T. R. Mackie, "Delivery modification as an alternative to patient repositioning in tomotherapy," in Proceedings of the 13th International Conference on Computers in Radiotherapy, edited by W. Schlegel and T. Bortfeld (Springer, Berlin, 2000), pp. 297-299.
-
(2000)
Proceedings of the 13th International Conference on Computers in Radiotherapy
, pp. 297-299
-
-
Olivera, G.H.1
Fitchard, E.E.2
Reckwerdt, P.J.3
Ruchala, K.J.4
Mackie, T.R.5
-
31
-
-
0035044866
-
A feasible method for clinical delivery verification and dose reconstruction in tomotherapy
-
J. M. Kapatoes, G. H. Olivera, K. J. Ruchala, P. J. Reckwerdt, J. S. Smilowitz, J. P. Balog, H. Keller, and T. R. Mackie, "A feasible method for clinical delivery verification and dose reconstruction in tomotherapy," Med. Phys. 28, 528-542 (2001).
-
(2001)
Med. Phys.
, vol.28
, pp. 528-542
-
-
Kapatoes, J.M.1
Olivera, G.H.2
Ruchala, K.J.3
Reckwerdt, P.J.4
Smilowitz, J.S.5
Balog, J.P.6
Keller, H.7
Mackie, T.R.8
-
32
-
-
0035062997
-
On the accuracy and effectiveness of dose reconstruction for tomotherapy
-
J. M. Kapatoes, G. H. Olivera, J. P. Balog, H. Keller, P. J. Reckwerdt, and T. R. Mackie, "On the accuracy and effectiveness of dose reconstruction for tomotherapy," Phys. Med. Biol. 46, 943-966 (2000).
-
(2000)
Phys. Med. Biol.
, vol.46
, pp. 943-966
-
-
Kapatoes, J.M.1
Olivera, G.H.2
Balog, J.P.3
Keller, H.4
Reckwerdt, P.J.5
Mackie, T.R.6
-
33
-
-
0030770289
-
Analysis and convergence of the iterative convolution/superposition dose reconstruction technique for multiple treatment beams and tomotherapy
-
T. R. McNutt, T. R. Mackie, and B. R. Paliwal, "Analysis and convergence of the iterative convolution/superposition dose reconstruction technique for multiple treatment beams and tomotherapy" Med. Phys. 24, 1465-1476 (1997).
-
(1997)
Med. Phys.
, vol.24
, pp. 1465-1476
-
-
McNutt, T.R.1
Mackie, T.R.2
Paliwal, B.R.3
-
34
-
-
0029113269
-
Intensity-modulated arc therapy with dynamic multileaf collimation: An alternative to tomotherapy
-
C. Yu, "Intensity-modulated arc therapy with dynamic multileaf collimation: an alternative to tomotherapy," Phys. Med. Biol. 40, 1435-1449 (1995).
-
(1995)
Phys. Med. Biol.
, vol.40
, pp. 1435-1449
-
-
Yu, C.1
-
35
-
-
0033867572
-
Intensity modulated Arc Therapy (IMAT) with centrally blocked rotational fields
-
C. Cotrutz, C. Kapas, and S. Webb. "Intensity modulated Arc Therapy (IMAT) with centrally blocked rotational fields," Phys. Med. Biol. 45, 2185-2206 (2000).
-
(2000)
Phys. Med. Biol.
, vol.45
, pp. 2185-2206
-
-
Cotrutz, C.1
Kapas, C.2
Webb, S.3
-
37
-
-
0028147625
-
A filtered backprojection dose calculation method for inverse treatment planning
-
T. Holmes and T. R. Mackie, "A filtered backprojection dose calculation method for inverse treatment planning," Med. Phys. 21, 303-313 (1994).
-
(1994)
Med. Phys.
, vol.21
, pp. 303-313
-
-
Holmes, T.1
Mackie, T.R.2
-
38
-
-
0027752810
-
Extra-focal radiation: A unified approach to the prediction of beam penumbra and output factors for megavoltage x-ray beams
-
M. B. Sharpe, D. A. Jaffray, J. J. Battista, and P. Munro, "Extra-focal radiation: A unified approach to the prediction of beam penumbra and output factors for megavoltage x-ray beams," Med. Phys. 20, 1417-1427 (1993).
-
(1993)
Med. Phys.
, vol.20
, pp. 1417-1427
-
-
Sharpe, M.B.1
Jaffray, D.A.2
Battista, J.J.3
Munro, P.4
-
39
-
-
0027752810
-
X-ray sources of medical linear accelerators: Focal and extra-focal radiation
-
D. A. Jaffray, J. J. Battista, A. Fenster, and P. Munro, "X-ray sources of medical linear accelerators: Focal and extra-focal radiation," Med. Phys. 20, 1417-1427 (1993).
-
(1993)
Med. Phys.
, vol.20
, pp. 1417-1427
-
-
Jaffray, D.A.1
Battista, J.J.2
Fenster, A.3
Munro, P.4
-
40
-
-
0026729304
-
Measurement of the source size in 6- and 18-MV radiotherapy linac
-
E. Loewenthal, E. Loewinger, E. Bar-Avraham, and G. Barnea, "Measurement of the source size in 6- and 18-MV radiotherapy linac," Med. Phys. 19, 687-690 (1993).
-
(1993)
Med. Phys.
, vol.19
, pp. 687-690
-
-
Loewenthal, E.1
Loewinger, E.2
Bar-Avraham, E.3
Barnea, G.4
-
41
-
-
0029900443
-
Analytic representation of head scatter factors for shaped photon beams using a two-component x-ray source model
-
M. Yu and R. Sloboda, "Analytic representation of head scatter factors for shaped photon beams using a two-component x-ray source model," Med. Phys. 23, 973-984 (1996).
-
(1996)
Med. Phys.
, vol.23
, pp. 973-984
-
-
Yu, M.1
Sloboda, R.2
-
42
-
-
0029991359
-
Flattening-filter-based empirical methods to parametrize the head scatter factor
-
K. Lam, M. Muthuswamy, and R. Ten Haken, "Flattening-filter-based empirical methods to parametrize the head scatter factor," Med. Phys. 23, 343-352 (1996).
-
(1996)
Med. Phys.
, vol.23
, pp. 343-352
-
-
Lam, K.1
Muthuswamy, M.2
Ten Haken, R.3
-
43
-
-
0030758971
-
Head scatter modelling for irregular field shaping and beam intensity modulation
-
A. Hounsell and J. Wilkinson, "Head scatter modelling for irregular field shaping and beam intensity modulation," Phys. Med. Biol. 42, 1737-1749 (1998).
-
(1998)
Phys. Med. Biol.
, vol.42
, pp. 1737-1749
-
-
Hounsell, A.1
Wilkinson, J.2
-
44
-
-
0026697038
-
Application of the convolution method for calculation of output factors for therapy photon beams
-
A. Ahnesjo, T. Knöös, and A. Montelius, "Application of the convolution method for calculation of output factors for therapy photon beams," Med. Phys. 19, 295-301 (1992).
-
(1992)
Med. Phys.
, vol.19
, pp. 295-301
-
-
Ahnesjo, A.1
Knöös, T.2
Montelius, A.3
-
45
-
-
0031466421
-
A dual source photon beam model used in convolution/superposition dose calculations for clinical megavoltage x-ray beams
-
H. Liu, T. R. Mackie, and E. McCullough, "A dual source photon beam model used in convolution/superposition dose calculations for clinical megavoltage x-ray beams," Med. Phys. 24, 1960-1974 (1997).
-
(1997)
Med. Phys.
, vol.24
, pp. 1960-1974
-
-
Liu, H.1
Mackie, T.R.2
McCullough, E.3
-
46
-
-
0031467698
-
Calculating output factors for photon beam radiotherapy using a convolution/superposition method based on a dual source photon beam model
-
H. Liu, T. R. Mackie, and E. McCullough, "Calculating output factors for photon beam radiotherapy using a convolution/superposition method based on a dual source photon beam model," Med. Phys. 24, 1975-1985 (1997).
-
(1997)
Med. Phys.
, vol.24
, pp. 1975-1985
-
-
Liu, H.1
Mackie, T.R.2
McCullough, E.3
-
48
-
-
85024960150
-
Dosimetric verification of inverse planned step and shoot multileaf collimator fields from a commercial treatment planning system
-
M. A. MacKenzie, M. Lachaine, D. Robinson, B. Murray, B. G. Fallone, and G. C. Field. "Dosimetric verification of inverse planned step and shoot multileaf collimator fields from a commercial treatment planning system," J. Appl. Clin. Med. Phys. 3, 97-109 (2002).
-
(2002)
J. Appl. Clin. Med. Phys.
, vol.3
, pp. 97-109
-
-
MacKenzie, M.A.1
Lachaine, M.2
Robinson, D.3
Murray, B.4
Fallone, B.G.5
Field, G.C.6
-
49
-
-
0025836884
-
Investigation of an FFT based correlation technique for the verification of radiation treatment setup
-
S. Jones and A. Boyer, "Investigation of an FFT based correlation technique for the verification of radiation treatment setup," Med. Phys. 18, 1116-1125 (1991).
-
(1991)
Med. Phys.
, vol.18
, pp. 1116-1125
-
-
Jones, S.1
Boyer, A.2
-
51
-
-
0018423633
-
Comparison of film and ion chamber systems for depth dose measurements for a 25 MV beam
-
D. W. Anderson and F. St. George, "Comparison of film and ion chamber systems for depth dose measurements for a 25 MV beam," Phys. Med. Biol. 24, 636-638 (1979).
-
(1979)
Phys. Med. Biol.
, vol.24
, pp. 636-638
-
-
Anderson, D.W.1
St. George, F.2
-
52
-
-
0028393602
-
Calibration of film for accurate megavoltage photon dosimetry
-
J. I. Hale, A. T. Kerr, and P. C. Schragge, "Calibration of film for accurate megavoltage photon dosimetry," Med. Dosim. 19, 43-46 (1994).
-
(1994)
Med. Dosim.
, vol.19
, pp. 43-46
-
-
Hale, J.I.1
Kerr, A.T.2
Schragge, P.C.3
-
53
-
-
0019504287
-
Film dosimetry of megavoltage beams: A practical method of isodensity to isodose curve conversion
-
J. Williamson, F. M. Khan, and S. C. Sharma, "Film dosimetry of megavoltage beams: a practical method of isodensity to isodose curve conversion." Med. Phys. 8, 94-98 (1981).
-
(1981)
Med. Phys.
, vol.8
, pp. 94-98
-
-
Williamson, J.1
Khan, F.M.2
Sharma, S.C.3
-
54
-
-
0034978370
-
Variation of sensitometric curves of radiographic films in high energy photon beams
-
C. Danciu, B. S. Proimos, J.-C. Rosenwald, and B. J. Mijnheer, "Variation of sensitometric curves of radiographic films in high energy photon beams," Med. Phys. 28, 966-974 (2001).
-
(2001)
Med. Phys.
, vol.28
, pp. 966-974
-
-
Danciu, C.1
Proimos, B.S.2
Rosenwald, J.-C.3
Mijnheer, B.J.4
|